- 05000482/LER-1987-054, :on 871127,ESF Actuated.Caused by Moisture Induced Corrosion of Electrical Connector on Radiation Monitor Skid.Connector Cleaned & Sealed W/Heat Shrink Moisture Seal + (ML20238C778)
- ML20238C779 + (ML20238C779)
- ML20238C781 + (ML20238C781)
- IR 05000312/1987036 + (ML20238C785)
- ML20238C786 + (ML20238C786)
- ML20238C787 + (ML20238C787)
- ML20238C788 + (ML20238C788)
- ML20238C789 + (ML20238C789)
- ML20238C791 + (ML20238C791)
- 05000352/LER-1987-038, :on 870802,nuclear Steam Supply Shutoff Sys Isolation Occurred.Caused by Short to Ground During Temporary Circuit Alteration Installation Due to Personnel Error.Personnel Counseled + (ML20238C793)
- ML20238C794 + (ML20238C794)
- ML20238C796 + (ML20238C796)
- ML20238C797 + (ML20238C797)
- ML20238C798 + (ML20238C798)
- ML20238C800 + (ML20238C800)
- ML20238C801 + (ML20238C801)
- IR 05000412/1987049 + (ML20238C803)
- ML20238C804 + (ML20238C804)
- ML20238C805 + (ML20238C805)
- ML20238C806 + (ML20238C806)
- ML20238C808 + (ML20238C808)
- ML20238C809 + (ML20238C809)
- ML20238C810 + (ML20238C810)
- ML20238C812 + (ML20238C812)
- ML20238C813 + (ML20238C813)
- ML20238C815 + (ML20238C815)
- ML20238C816 + (ML20238C816)
- 05000440/LER-1987-076, :on 871203,main Steam Drain Line Isolations Occurred.Caused by Inadequate Surveillance Instructions. Instructions Revised + (ML20238C818)
- ML20238C819 + (ML20238C819)
- IR 05000312/1987033 + (ML20238C821)
- RBG-24546, Special Rept:On 870724,seismic Monitor 1ERS-NBE1B Declared Inoperable When Surveillance Interval Expired Per Tech Spec 4.0.3 & Action Statement Entered.Monitor Will Still Register Seismic Events.No Such Events Have Occurred at Facility + (ML20238C822)
- ML20238C823 + (ML20238C823)
- ML20238C825 + (ML20238C825)
- 05000354/LER-1987-035, :on 870804,standby Liquid Control Sys B Started,Squib Valve Fired & RWCU Isolated.Cause Undetermined.Piping Flushed & Restored to Svc & Squib Valve Replaced & Tested Satisfactory + (ML20238C826)
- ML20238C827 + (ML20238C827)
- ML20238C830 + (ML20238C830)
- ML20238C831 + (ML20238C831)
- ML20238C832 + (ML20238C832)
- ML20238C834 + (ML20238C834)
- ML20238C835 + (ML20238C835)
- ML20238C836 + (ML20238C836)
- ML20238C837 + (ML20238C837)
- ML20238C838 + (ML20238C838)
- ML20238C840 + (ML20238C840)
- ML20238C841 + (ML20238C841)
- ML20238C843 + (ML20238C843)
- ML20238C844 + (ML20238C844)
- ML20238C845 + (ML20238C845)
- ML20238C846 + (ML20238C846)
- ML20238C847 + (ML20238C847)
- ML20238C848 + (ML20238C848)