Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML20236N989 + (ML20236N989)
- ML20236N990 + (ML20236N990)
- ML20236N991 + (ML20236N991)
- ML20236N993 + (ML20236N993)
- ML20236N994 + (ML20236N994)
- ML20236N995 + (ML20236N995)
- TXX-6920, Interim Deficiency Rept CP-85-42 Re Possible Adverse Effect of Substitution of Rectangular & Oversized Preformed Sections of Thermolag on Conduit Installations.Initially Reported on 861021.Next Rept Will Be Submitted by 880203 + (ML20236N997)
- ML20236N999 + (ML20236N999)
- ST-HL-AE-2409, Application for Amend to License NPF-71 & Fsar,Allowing Response Time of 8 for Overtemp delta-T & Overpower delta-T Instrumentation Based on Supporting Analysis Discussed in Encl Safety Evaluation.Fee Paid + (ML20236P000)
- ML20236P002 + (ML20236P002)
- ML20236P005 + (ML20236P005)
- ML20236P006 + (ML20236P006)
- TXX-6954, Final Deficiency Rept CP-87-50 Re Abnormal Thrust Bearing Temp on Turbine Driven Auxiliary Feedwater Pump.Initially Reported on 870727.Pumps Will Be Dismantled & Balancing Drum Installed.Records Will Be Available for Review After 880131 + (ML20236P007)
- ML20236P008 + (ML20236P008)
- ML20236P009 + (ML20236P009)
- ML20236P010 + (ML20236P010)
- ML20236P011 + (ML20236P011)
- ML20236P012 + (ML20236P012)
- TXX-6938, Revises Replacement Date of Valve Bonnet to 880331 in Response to Violation Noted in Insp Rept 50-445/86-22 + (ML20236P014)
- ML20236P015 + (ML20236P015)
- ML20236P016 + (ML20236P016)
- IR 05000482/1987023 + (ML20236P017)
- ML20236P019 + (ML20236P019)
- 05000413/LER-1987-038, :on 871012,discovered That Hourly Fire Watches Not Performed for Room 428.Caused by Personnel Error.Room 428 Hatch Covers Installed & Incident Reviewed W/Radwaste Chemistry Personnel.Hourly Fire Watch Resumed + (ML20236P022)
- ML20236P023 + (ML20236P023)
- ML20236P025 + (ML20236P025)
- ML20236P026 + (ML20236P026)
- ML20236P027 + (ML20236P027)
- ML20236P028 + (ML20236P028)
- IR 05000312/1987019 + (ML20236P029)
- TXX-6942, Interim Deficiency Rept CP-87-75 Re Failure to Properly Record Surface Temps Prior to Placement of epoxy-type Grouts.Initially Reported on 870824.Evaluation Continuing. Next Rept by 880202 + (ML20236P031)
- ML20236P032 + (ML20236P032)
- ML20236P033 + (ML20236P033)
- ML20236P034 + (ML20236P034)
- ML20236P036 + (ML20236P036)
- ML20236P037 + (ML20236P037)
- ML20236P038 + (ML20236P038)
- ML20236P039 + (ML20236P039)
- ML20236P042 + (ML20236P042)
- ML20236P043 + (ML20236P043)
- ML20236P045 + (ML20236P045)
- IR 05000344/1987026 + (ML20236P046)
- IR 05000312/1987020 + (ML20236P047)
- ML20236P051 + (ML20236P051)
- U-601073, Forwards Insp Actions Taken for Plant BWR Stainless Steel Piping,Per Generic Ltr 84-11 on Igscc.Actions Taken to Mitigate IGSCC During Const Recommended by Rev 1 to NUREG-0313 + (ML20236P053)
- ML20236P054 + (ML20236P054)
- ML20236P055 + (ML20236P055)
- ML20236P058 + (ML20236P058)
- ML20236P060 + (ML20236P060)
- ML20236P061 + (ML20236P061)
- ML20236P063 + (ML20236P063)