Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML20236L305 + (ML20236L305)
- ML20236L306 + (ML20236L306)
- ML20236L307 + (ML20236L307)
- ML20236L308 + (ML20236L308)
- ML20236L310 + (ML20236L310)
- ML20236L311 + (ML20236L311)
- ML20236L315 + (ML20236L315)
- ML20236L316 + (ML20236L316)
- ML20236L317 + (ML20236L317)
- ML20236L320 + (ML20236L320)
- ML20236L321 + (ML20236L321)
- W3P87-1731, Forwards Rev 3 to 10-Yr Inservice Insp Program Waterford Steam Electric Station Unit 3. Relief from ASME Section XI Code & Approval of Revised Program Requested.Summary of Changes Encl.Fee Paid + (ML20236L322)
- ML20236L324 + (ML20236L324)
- PNO-III-87-104, on 870801,reactor Scram Occurred as Result of Turbine & Generator Trips Due to Fault in Main Transformer. Licensee Investigating Cause of Problem.Unit Expected to Be Shut Down for Several Wks for Replacement of Transformer + (ML20236L326)
- ML20236L329 + (ML20236L329)
- ML20236L332 + (ML20236L332)
- ML20236L334 + (ML20236L334)
- ML20236L335 + (ML20236L335)
- ML20236L337 + (ML20236L337)
- ML20236L339 + (ML20236L339)
- ML20236L340 + (ML20236L340)
- 05000458/LER-1986-068, :on 861223,RCIC High Steam Supply Flow Detection Transmitter Failed.Caused by Moisture Accumulating in Electronics Head.Transmitter Replaced & Sys Declared Operable on 861227 + (ML20236L341)
- ML20236L342 + (ML20236L342)
- ML20236L344 + (ML20236L344)
- ML20236L345 + (ML20236L345)
- ML20236L348 + (ML20236L348)
- ML20236L350 + (ML20236L350)
- ML20236L351 + (ML20236L351)
- ML20236L353 + (ML20236L353)
- ML20236L354 + (ML20236L354)
- IR 05000271/1998008 + (ML20236L355)
- ST-HL-AE-2400, Final Part 21 & Deficiency Rept Re Failure of Tubes in Component Cooling Water Hxs.Initially Reported on 871006. Discussions W/Vendor,Struthers Wells-Gulfport,Inc Indicated That Shell Side Flow Induced Vibration Problem Existed + (ML20236L358)
- ML20236L360 + (ML20236L360)
- 05000320/LER-1998-001, Forwards LER 98-001-00 Re Condition Which Was Evaluated & Determined to Be Reportable on 980615.NRC Form 366 Contains Abstract,Providing Brief Description of Evaluated Condition + (ML20236L361)
- ML20236L362 + (ML20236L362)
- ML20236L364 + (ML20236L364)
- ML20236L365 + (ML20236L365)
- ML20236L366 + (ML20236L366)
- ML20236L367 + (ML20236L367)
- ML20236L368 + (ML20236L368)
- 05000320/LER-1998-001-02, :on 980604,flood Barriers Breached Between Turbine Bldg & Control Bldg Area.Caused by Work Planning Process for Dismantlement Work Failed to Include Adequate Controls.Openings Verified to Be Sealed + (ML20236L370)
- ML20236L371 + (ML20236L371)
- PNO-II-87-054, on 870731,approx 200,000 Ci Tritium Gas Accidentally Released from Savannah River Plant Through Facility Stack During Maint Procedure.No Injuries Occurred & Evacuation of Site Employees Unnecessary + (ML20236L372)
- ML20236L373 + (ML20236L373)
- IR 05000456/1998010 + (ML20236L375)
- ML20236L376 + (ML20236L376)
- 05000455/LER-1987-001-01, :on 870115,during Initial Criticality/Low Power Physics start-up Test Requiring Bistable Trip,Reactor Trip Occurred.Caused by Reactor Coolant Resistance Temp Detector Splice Failure.Splice Connection Corrected + (ML20236L377)
- ML20236L379 + (ML20236L379)
- ML20236L382 + (ML20236L382)
- ML20236L383 + (ML20236L383)
- ML20236L385 + (ML20236L385)