- RBG-21-830, Responds to R Caldwell Re Use of Temporary Badges.Certifies That All Temporary Key Cards Deleted from Security Access Sys.Permanent Access Controls in Effect + (ML20235X258)
- ML20235X259 + (ML20235X259)
- ML20235X261 + (ML20235X261)
- ML20235X262 + (ML20235X262)
- IR 05000295/1987026 + (ML20235X266)
- ML20235X267 + (ML20235X267)
- ML20235X271 + (ML20235X271)
- 05000301/LER-1989-001, :on 890203,operator Dicovered Both Supply Breakers in Open Position Due to Simultaneous Automatic Turbine Runback.Cause Not Positively Identified.Efforts Will Be Made to Ease Difficulty W/Supply Breakers + (ML20235X275)
- 05000352/LER-1987-046, :on 870907,reactor Protection Sys Initiated Full Reactor Scram.Caused by Instrument Air Supply Root Valves Not Fully Open.Root Valves Opened Fully & Scram Reset + (ML20235X276)
- ML20235X278 + (ML20235X278)
- ML20235X279 + (ML20235X279)
- ML20235X281 + (ML20235X281)
- 05000333/LER-1987-016, :on 870916,w/plant Operating at 100% Power, Automatic Isolation of RCIC Sys Occurred.Caused by Failure of Operator to Follow Prescribed Sequence of Surveillance Test Procedure.Operator Counseled + (ML20235X285)
- ML20235X286 + (ML20235X286)
- ML20235X288 + (ML20235X288)
- ML20235X293 + (ML20235X293)
- ML20235X294 + (ML20235X294)
- ML20235X300 + (ML20235X300)
- JAFP-87-0814, Responds to NRC Re Violations Noted in Insp Rept 50-333/86-14.Corrective Actions:Nonconforming Electrical Cable Splices Respliced & Training in Spec IS-E-08 Re Electrical Termination & Splice Insulation Instituted + (ML20235X301)
- ML20235X302 + (ML20235X302)
- ML20235X303 + (ML20235X303)
- W3P87-2202, Monthly Operating Rept for Sept 1987 + (ML20235X307)
- ML20235X309 + (ML20235X309)
- B12695, Retracts 870729 Application for Amend to License DPR-61, Revising Tech Specs Re Feedwater Isolation Valves.New Proposed Rev W/Corrections & Clarifications Pertaining to Surveillance Requirements Will Be Provided at Later Date + (ML20235X311)
- ML20235X312 + (ML20235X312)
- ML20235X313 + (ML20235X313)
- ML20235X314 + (ML20235X314)
- B12591, Forwards Response to SALP Rept for 18-month Period Ending 870228 for Facility.Concurs W/Board Observations.Steps Taken to Address Concerns Identified + (ML20235X315)
- ML20235X317 + (ML20235X317)
- ML20235X318 + (ML20235X318)
- ML20235X321 + (ML20235X321)
- ML20235X323 + (ML20235X323)
- L-87-421, Monthly Operating Repts for Sept 1987 + (ML20235X325)
- ML20235X327 + (ML20235X327)
- ML20235X331 + (ML20235X331)
- NRC-87-0093, Monthly Operating Rept for June 1987 + (ML20235X333)
- ML20235X334 + (ML20235X334)
- ML20235X336 + (ML20235X336)
- IR 05000266/1989005 + (ML20235X337)
- SNRC-1354, Forwards Renewed SPDES Permit NY-002 6344 for Facility,Per App B to License NPF-36 + (ML20235X339)
- ML20235X341 + (ML20235X341)
- ML20235X342 + (ML20235X342)
- ML20235X347 + (ML20235X347)
- 05000373/LER-1987-025-01, :on 870618,while Performing Surveillance LTS-600-11,snubber Found Omitted from Surveillance List for Rcic.Caused by Error in Documentation.Snubber Replaced, Tested & Added to Station Surveillances + (ML20235X352)
- ML20235X356 + (ML20235X356)
- ML20235X358 + (ML20235X358)
- ML20235X359 + (ML20235X359)
- ML20235X361 + (ML20235X361)
- ML20235X362 + (ML20235X362)
- ML20235X364 + (ML20235X364)
- ML20235X370 + (ML20235X370)