- ML20203N872 + (ML20203N872)
- ML20203N873 + (ML20203N873)
- 05000327/LER-1986-042, :on 860908,two Tech Spec Surveillance Requirements Not Performed.Caused by Inadequate Procedures. SI-129 Revised to Require Less than 1,700 Psi & Westinghouse cross-calibr Procedure Implemented + (ML20203N874)
- ML20203N875 + (ML20203N875)
- ML20203N876 + (ML20203N876)
- B12023, Forwards Proposed Rev 8 to QA Program Topical Rept for Review & Approval.Changes Reduce Commitments Contained in Previously Accepted QA Program Description.Fee Paid + (ML20203N877)
- ML20203N879 + (ML20203N879)
- IR 05000461/1986063 + (ML20203N881)
- ML20203N882 + (ML20203N882)
- PNO-V-86-023, on 860426,ESF Load Sequencer for Train a Emergency Diesel Generator Inoperable.Caused by Broken Conductor in Relay Wire Discovered in Late 1985 But Mistakenly Considered Unimportant Grounding Path + (ML20203N883)
- 3F0486-15, Advises That Since Installation of Emergency Feedwater Initiation & Control Sys,Per NUREG-0737,Item II.E.1.2, Several Actuations Occurred.Temporary Fix of Installing Time Delay Relay Mfg by Logitek,Inc Underway + (ML20203N884)
- SNRC-1256, Informs of Intention to Maintain Separate Shift Technical Advisor Position to Provide Engineering Expertise Until First Refueling Outage.Generic Ltr 86-04 Authorizes Utils to Combine Position W/Senior Reactor Operator Position + (ML20203N886)
- IR 05000413/1986004 + (ML20203N888)
- ML20203N892 + (ML20203N892)
- ML20203N895 + (ML20203N895)
- ML20203N899 + (ML20203N899)
- ML20203N901 + (ML20203N901)
- ML20203N902 + (ML20203N902)
- 05000237/LER-1986-008-05, :on 860331,automatic Start of Standby Gas Treatment Sys a & Reactor Bldg Ventilation Isolation Occurred Due to High Radiation Trip.Caused by Failure of Geiger Muller Tube in Radiation Monitor + (ML20203N904)
- ML20203N905 + (ML20203N905)
- ML20203N906 + (ML20203N906)
- 05000323/LER-1986-011-03, :on 860330,manual Unit Trip Initiated Due to Condenser Tube Failure.Caused by Condenser Steam Dump Valve Malfunctioning Due to Mechanical Problem Bending Positioner Linkage on Valve.Valve Repair Underway + (ML20203N909)
- ML20203N910 + (ML20203N910)
- ML20203N911 + (ML20203N911)
- ML20203N914 + (ML20203N914)
- ML20203N917 + (ML20203N917)
- ML20203N919 + (ML20203N919)
- ML20203N920 + (ML20203N920)
- ML20203N922 + (ML20203N922)
- ML20203N923 + (ML20203N923)
- ML20203N924 + (ML20203N924)
- A03864, Advises That Program to Replace All Hfa Relays W/Recommended Century Series in Class 1E Applications Completed,Per IE Bulletin 84-02, Failures of GE Type Hfa Relays in Use in Class 1E Safety Sys & Util + (ML20203N926)
- ML20203N927 + (ML20203N927)
- ML20203N929 + (ML20203N929)
- ML20203N932 + (ML20203N932)
- ML20203N933 + (ML20203N933)
- IR 05000254/1986007 + (ML20203N934)
- ML20203N935 + (ML20203N935)
- ML20203N936 + (ML20203N936)
- ML20203N938 + (ML20203N938)
- ML20203N939 + (ML20203N939)
- ML20203N940 + (ML20203N940)
- ML20203N941 + (ML20203N941)
- ML20203N942 + (ML20203N942)
- IR 05000424/1986017 + (ML20203N943)
- ML20203N944 + (ML20203N944)
- ML20203N946 + (ML20203N946)
- ML20203N947 + (ML20203N947)
- ML20203N950 + (ML20203N950)
- ML20203N953 + (ML20203N953)
- ML20203N955 + (ML20203N955)