f)C3 Octobsr 9, 1986 EN 86-76 0FFICE~0F INSPECTION AND ENFORCEMENT NOTIFICATION OF SIGNIFICANT ENFORCEMENT ACTION Licensee:

Portland General Electric Company (Trojan Nuclear Power Plant)

Docket No. SD-344

Subject:

PROPOSED IMPOSITION OF CIVIL PENALTY - $50,000 This is to inform the Commission that a Notice of Violation and Proposed Imposition of Civil Penalty in the amount of Fifty Thousand ($50,000) will be issued on or about October 14, 1986 to Portland General Electric Company. This -

action is based on two violations of NRC requirements. The first violation involves the failure to maintain operable flow paths for the Resident Heat Removal System for cold leg injection.

Flow paths were operable only for two of the four reactor coolant loops. The second violation involves the incomplete inspection by a contract quality control inspector for the -installa-tion of a pressurizer safety valve. The quality control inspector failed to.

properly witness the torquing of bolts for the valve and signed the inspection record to indicate that the inspection had taken place.

It should be noted that the licensee has not been specifically informed of the enforcement action. The Regional Administrator has been authorized by the Director, Office of Inspection and Enforcement, to sign this action. The schedule' of issuance and notification is:

Mailing of Notice October 15, 1986 Telephone Notification of Licensee October 15, 1986 A news release has been prepared and will be issued after the licensee receives the Notice. The State of Oregon will be notified.

The licensee has thirty. days from the date of the Notice in which to respond.

Following NRC evaluation of the response, the civil penalty may be remitted, mitigated, or imposed by Order.

Contact:

H. Wong, IE 29635 J. Axelrad, IE 24909 Distribution:

H Street /// [2-MNBB M,0 0 Phillips//I(/ /

EW Willste B lO 4 Chairman Zech EDO NRR IE NMSS Comm. Roberts DED/ROGR OIA Comm. Asselstine PA 01 Comm. Bernthal ELD AE0D Comm. Carr RM ACRS-SECY Air Rights /M Regional Offices MAIL CA SP RI ///Vo RIV //> fo.ADM: Doc. Mgt. Br.

PE RII //f t/c RV nye PDR RIII /c yo RES PRELIMINARY INFORMATION - N01 FOR PUBLIC DISCLOSURE UNTIL PUBLICLY ANN 0UNCED.

8610200141 861009

$-86kb PDR.

l'{ ;

2> 3 uI

,