- ML20203N585 + (ML20203N585)
- ML20203N586 + (ML20203N586)
- ML20203N587 + (ML20203N587)
- ML20203N588 + (ML20203N588)
- ML20203N589 + (ML20203N589)
- 05000440/LER-1986-039-01, Forwards LERs 86-053-00,86-054-00,86-055-00,86-056-00, 86-057-00 & 86-039-01.LER 86-039-01 Provides Addl Info Re Corrective Actions + (ML20203N590)
- NG-86-3044, Suppls 860528 Response to IE Bulletin 85-003,Item E Re motor-operated Valve Common Mode Failures During Plant Transients.Max Expected Differential Pressures During Opening & Closing of Valves Provided + (ML20203N594)
- U-600689, Responds to NRC Re Violations Noted in Insp Rept 50-461/86-37.Corrective Actions:Procedure CPS 9052.02, LPCS Valve Operability Checks, Revised to Incorporate Criteria for Opening Time of LPCS Injection Valve + (ML20203N595)
- ML20203N596 + (ML20203N596)
- 05000440/LER-1986-053, :on 860901,containment & Drywell Vacuum Breakers Discovered Open.Caused by Procedural Error. Integrated Operating Instruction for Cold Startup Revised. Control Room Operators Counseled + (ML20203N597)
- 05000341/LER-1986-027, :on 860831,valve Closed & Could Not Be Reopened During Monthly Operability Check.Caused by Equipment Failure Due to Corrosion.Corroded Disc & Shaft Replaced W/Stainless Steel Components + (ML20203N599)
- ML20203N600 + (ML20203N600)
- ML20203N601 + (ML20203N601)
- ML20203N604 + (ML20203N604)
- ML20203N605 + (ML20203N605)
- 05000440/LER-1986-054, :on 860902,07,11,13,15 & 19,RCIC Isolations Occurred.Caused by Instrument Isolation Valve Failure & Impulse Line Slope Problems,Leak Detection Response Time & Personnel Error.Valves Repaired or Replaced + (ML20203N607)
- ML20203N608 + (ML20203N608)
- 05000254/LER-1986-027-02, :on 860905,RCIC Pump Discharge to Reactor Vessel Valve 1-1301-48 Failed to Open.Caused by High Pickup Voltage on 250-volt Dc Motor Operated Valve Contactor. Voltage Changed & Valve Cycled Successfully + (ML20203N609)
- ML20203N610 + (ML20203N610)
- ML20203N611 + (ML20203N611)
- ML20203N613 + (ML20203N613)
- 05000440/LER-1986-055, :on 860902,reactor Scram Occurred.Caused by Sudden Increase in Sensed Pressure for Steam Bypass Valves Controller.Pressure Regulators & Instrumentation Valve Lineups Recalibr,Procedures Revised & Mgt Directive Issued + (ML20203N614)
- ML20203N616 + (ML20203N616)
- 05000482/LER-1986-047, :on 860904,waste Gas Decay Tank 8 Found Slowly Decreasing in Pressure During Planned Release from Tank 2. Caused by Leak Into Tank 2 Via Drain Connections W/Common Header.Drain Valve Repaired + (ML20203N617)
- ML20203N620 + (ML20203N620)
- 05000440/LER-1986-056, :on 860902 & 29,RWCU Containment Isolations Occurred.Caused by Flow Control Valve Problems,Placement of Blowdown Flow Element & Insufficient Operating Instructions. Design Changes Initiated.Instructions Will Be Revised + (ML20203N621)
- IR 05000424/1986025 + (ML20203N622)
- 3F1086-01, Declines to Fulfill NRC 860919 Request for Meteorological Data,Per IE Info Notice 84-91.Data of Questionable Use in Evaluating Adequacy of Data Collection Program.Util Meteorological Measurements Program Adequate + (ML20203N624)
- 05000440/LER-1986-057, :on 860903,containment Isolation Valves Not Deactivated in Closed Position.Caused by Failure of Nonconformance Rept Program to Require Routing of Environ Qualification Deficiencies to Control Room.Program Revised + (ML20203N625)
- ML20203N627 + (ML20203N627)
- PNO-V-86-067, on 861001,fuel Assembly in Vessel Found W/ 10-degree Tilt & Resting Askew Against Core Baffle Plate. Cause Under Investigation.Program & Special Tools Prepared to Return Assembly to Vertical Position + (ML20203N629)
- ML20203N631 + (ML20203N631)
- ML20203N632 + (ML20203N632)
- ML20203N636 + (ML20203N636)
- ML20203N637 + (ML20203N637)
- ML20203N638 + (ML20203N638)
- ML20203N641 + (ML20203N641)
- ML20203N642 + (ML20203N642)
- ML20203N643 + (ML20203N643)
- IR 05000348/1986006 + (ML20203N645)
- ML20203N646 + (ML20203N646)
- ML20203N647 + (ML20203N647)
- ML20203N648 + (ML20203N648)
- ML20203N651 + (ML20203N651)
- ML20203N653 + (ML20203N653)
- ML20203N654 + (ML20203N654)
- ML20203N655 + (ML20203N655)
- ML20203N656 + (ML20203N656)
- ML20203N657 + (ML20203N657)
- IR 05000269/1985041 + (ML20203N659)