- 05000482/LER-1986-004, :on 860213,discovered That Hourly Fire Watches Not Established on 860211,following Removal of Fireproofing Matl from Auxiliary Bldg.Caused by Personnel Error. Supervisor Assigned to Oversee Removal of Matl + (ML20141N599)
- 05000263/LER-1986-005, :on 860209,isolation of Reactor Bldg Ventilation Sys & Initiation of Standby Gas Treatment Sys Occurred Due to Reactor Bldg Vent wide-range Gas Monitor Trips.Caused by Personnel Error.Manual Revised + (ML20141N600)
- 05000454/LER-1986-007-02, :on 860212,process Radiation Monitor OPR34J Went Into Interlock Mode Due to Noise Spike on Monitor Gas Channel.Cause of Noise Spike Unknown.Troubleshooting Being Performed to Determine Cause + (ML20141N601)
- 05000529/LER-1986-006-01, :on 860208,containment Purge Isolation & Control Room Essential Filtration Actuation Signals Actuated on Both Channels.Caused by Failure of Technician to Fully Analyze Effects of Actions Prior to Beginning + (ML20141N602)
- ML20141N603 + (ML20141N603)
- ML20141N604 + (ML20141N604)
- ML20141N605 + (ML20141N605)
- 05000219/LER-1984-015, :on 840125 & 0625,discovered That Hfa Relays W/Date Code Hw Began to Fog W/Unknown Oily Vapor When Energized.Caused by Mist Created When Coil Energized.Relays Cleaned + (ML20141N606)
- 05000255/LER-1986-010, :on 860209,pipe Support Discovered Missing from Integrated Leak Rate Test Instrument Line.Cause Assumed to Be Removal of Hanger During Removal of Integrated Leak Rate Test Instrumentation Panel in 1981 + (ML20141N607)
- 05000322/LER-1986-004, :on 860225,discovered That Three Individuals Not Properly Logged Into Primary Containment Area Personnel Hatch.Caused by Security Guard Error.Security Supervisors Will Conduct Random Checks to Ensure Logging + (ML20141N612)
- 05000155/LER-1986-002-01, :on 860211,leak Rate for Reactor Depressurization Sys Isolation Valves SV-4985,SV-4986 & SV-4987 Exceeded Tech Spec Limits.Caused by Quarterly Surveillance Test Aggravating Leaking Valves + (ML20141N615)
- 05000325/LER-1986-006-01, :on 860212 & 16,automatic Isolations of Common Control Bldg HVAC Occurred Due to Actuations of Chlorination Sys Storage Area Detector X-AT-2979.Caused by Chlorine Due to Maint Activity & Flange Leak + (ML20141N618)
- ML20141N619 + (ML20141N619)
- ML20141N620 + (ML20141N620)
- 05000271/LER-1986-004, :on 860208,standby Liquid Control (SLC) Squib Valve a Failed to Fire During Annual Surveillance.On 860211, SLC Squib Valve B Failed to Fire & SLC Sys Declared Inoperable.Caused by Faulty Trigger Assemblies + (ML20141N621)
- ML20141N622 + (ML20141N622)
- ST-HL-AE-1616, Interim Deficiency Rept Re Pipe Stress Analysis Using Multiple Response Spectra.Initially Reported on 860224. Impacted Calculations Being Reanalyzed W/Correct Input for ME-101.Final Rept Anticipated by 860331 + (ML20141N623)
- 05000423/LER-1986-016, :on 860208,containment Area CS-01 Exceeded 120 F Specified Limit.Caused by Pressurizer Cubicle Exceeding Temp Limit.All Environmentally Qualified Equipment Verified as Operable + (ML20141N624)
- ML20141N625 + (ML20141N625)
- 05000323/LER-1985-014-01, :on 851005,unit Entered Mode 2 (Hot Shutdown) W/Steam Generator Main Feedwater Isolation Valve FCV-439 Inoperable.Caused by Incorrect Wiring Terminations in Control Sys.Maint Bulletin Issued + (ML20141N626)
- 0CAN038602, Semiannual Radioactive Effluent Rept,Third & Fourth Quarters 1985 + (ML20141N627)
- ML20141N628 + (ML20141N628)
- 05000322/LER-1986-005, :on 860208,control Room Air Conditioning Sys/ Reactor Bldg Standby Ventilation Sys B Side Initiation & Partial Nuclear Steam Supply Shutoff Sys Isolation Occurred. Caused by Procedural Deficiency + (ML20141N632)
- ML20141N633 + (ML20141N633)
- 05000344/LER-1986-001, :on 860208,during Full Power,Circulating Water Pump a Tripped,Resulting in High Negative Flux Rate Reactor Trip.Caused by Low Lube Oil Flow Due to Drop in Lube Oil Temp.Lube Oil Temp Restored to Normal + (ML20141N634)
- ML20141N635 + (ML20141N635)
- 05000271/LER-1986-003, :on 860127 & 28,during Testing,Two Main Steam Relief Valves Exceeded Setpoint Pressure Requirements of Tech Spec Section 2.2.B.Caused by Pilot Stage Leakage from Steam Cuts on Pilot Disc.Valves Being Repaired + (ML20141N637)
- ML20141N638 + (ML20141N638)
- ML20141N639 + (ML20141N639)
- ML20141N640 + (ML20141N640)
- ML20141N641 + (ML20141N641)
- ML20141N642 + (ML20141N642)
- 05000482/LER-1986-010, :on 860214,hourly Rather than Continuous Fire Watch Established for Inoperable Spray/Sprinkler Sys.Caused by Personnel Error.Individual Counseled & Info Will Be Incorporated Into Required Reading + (ML20141N643)
- ML20141N644 + (ML20141N644)
- ML20141N645 + (ML20141N645)
- ML20141N646 + (ML20141N646)
- ML20141N648 + (ML20141N648)
- ML20141N649 + (ML20141N649)