Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML20140D066 + (ML20140D066)
- ML20140D067 + (ML20140D067)
- ML20140D069 + (ML20140D069)
- ML20140D071 + (ML20140D071)
- ML20140D072 + (ML20140D072)
- 05000265/LER-1997-004-06, :on 970509,drywell Equipment Drain Sump & Floor Drain Sump Covers Were Not Constructed IAW Design Drawings, Due to Original Construction Error.Design Change Package Has Been Completed + (ML20140D073)
- ML20140D075 + (ML20140D075)
- ML20140D076 + (ML20140D076)
- 05000306/LER-1997-002-02, :on 970318,discharge Valves to RCS Cold Legs Were Closed When RCS Was Above Shutdown Because of Administrative Error.Training Was Provided on Intent of Motherhood Clause to Operations Staff + (ML20140D078)
- IR 05000285/1997008 + (ML20140D079)
- 05000373/LER-1997-011, :on 970318,source Range Monitor Detector Retract Permit Enabled Lower than Allowed by TS Due to Nonconservative Setpoint in Inadequate Procedure.Setpoint Determination Was Performed + (ML20140D081)
- 05000373/LER-1997-013, :on 970320,identified Concern Regarding LaSalle Electrical Surveillance Isolation Logic Sys Functional Test. Caused by Misinterpretation of TS Surveillance Requirement 4.3.2.2.Procedures Revised + (ML20140D083)
- ML20140D084 + (ML20140D084)
- ML20140D086 + (ML20140D086)
- ML20140D088 + (ML20140D088)
- ML20140D089 + (ML20140D089)
- ML20140D090 + (ML20140D090)
- ML20140D091 + (ML20140D091)
- ML20140D092 + (ML20140D092)
- ML20140D093 + (ML20140D093)
- ST-HL-AE-1615, Final Rept Re Interaction of safety-related & nonsafety- Related Instruments Connected to Same Process Taps.Initially Reported on 851009.Item Not Reportable Per 10CFR50.55(e) + (ML20140D094)
- ML20140D095 + (ML20140D095)
- ML20140D096 + (ML20140D096)
- ML20140D097 + (ML20140D097)
- 05000352/LER-1985-098, :on 851219,w/unit in Startup Mode at 0% Power, RWCU Sys Isolation Occurred.Caused by Incorrect Procedure Rev During Installation of Plant Mod.Sys Restored to Svc & Procedure Rev Corrected + (ML20140D098)
- ML20140D099 + (ML20140D099)
- ML20140D100 + (ML20140D100)
- ML20140D102 + (ML20140D102)
- ML20140D103 + (ML20140D103)
- ML20140D104 + (ML20140D104)
- IR 05000213/1997004 + (ML20140D106)
- 05000352/LER-1985-099, :on 851223,unplanned Actuation of Nuclear Steam Supply Shutoff Sys Occurred W/Unit in Operational Mode 1 at 72% Power.Caused by Signal Loss,Possibly Due to Disturbance to Rack Connectors + (ML20140D107)
- ML20140D108 + (ML20140D108)
- ML20140D109 + (ML20140D109)
- IR 05000320/1986003 + (ML20140D110)
- ML20140D111 + (ML20140D111)
- ML20140D112 + (ML20140D112)
- PNO-I-97-035, on 970605,200 Mci Xenon-133 Released to Atmosphere During Performance of Experimental Therapy on Animal.Licensee Currently Investigating Cause of Event & Region I Will Continue to Monitor Licensee Actions + (ML20140D113)
- ML20140D114 + (ML20140D114)
- ML20140D115 + (ML20140D115)
- ML20140D117 + (ML20140D117)
- ML20140D118 + (ML20140D118)
- 05000281/LER-1985-014-01, :on 851226,control Rod Urgent Failure Alarm Occurred as Rods Stepping in Automatic.Caused by Problem in Logic Cabinet Pulser Card A101.Card Replaced & Sys Tested Satisfactorily + (ML20140D119)
- ML20140D120 + (ML20140D120)
- ML20140D122 + (ML20140D122)
- ML20140D123 + (ML20140D123)
- ML20140D124 + (ML20140D124)
- ML20140D126 + (ML20140D126)
- ML20140D128 + (ML20140D128)
- ML20140D129 + (ML20140D129)
- ML20140D130 + (ML20140D130)