- PNO-III-85-102, on 851214,during Outage,Both Trains of RHR Sys Lost When Water in Reactor Vessel Drained Below Level of Suction Line.Caused by Erroneous Control Room Indication of RCS Configuration Used for Outage + (ML20138L055)
- ML20138L056 + (ML20138L056)
- ML20138L057 + (ML20138L057)
- ML20138L058 + (ML20138L058)
- 05000352/LER-1985-077, :on 850926,spurious Div IV Trip Signals Received Resulting in Load Shedding in Anticipation of Diesel Generator Loading.Caused by Loose Connection in Power Panel.Connection Tightened + (ML20138L061)
- ML20138L062 + (ML20138L062)
- ML20138L064 + (ML20138L064)
- ML20138L065 + (ML20138L065)
- ML20138L066 + (ML20138L066)
- ML20138L069 + (ML20138L069)
- ML20138L070 + (ML20138L070)
- ML20138L072 + (ML20138L072)
- ML20138L074 + (ML20138L074)
- ML20138L075 + (ML20138L075)
- ML20138L076 + (ML20138L076)
- ML20138L077 + (ML20138L077)
- IR 05000213/1985020 + (ML20138L078)
- ML20138L080 + (ML20138L080)
- ML20138L081 + (ML20138L081)
- ML20138L082 + (ML20138L082)
- ML20138L083 + (ML20138L083)
- ML20138L084 + (ML20138L084)
- IR 05000455/1985031 + (ML20138L086)
- ML20138L088 + (ML20138L088)
- ML20138L090 + (ML20138L090)
- BSEP-85-1760, Advises That Completion Date for Maint Surveillance Test Procedure Program Revised to 860131,in Response to Insp Repts 50-324/84-31 & 50-325/84-31.Commitment Schedule Encl + (ML20138L091)
- IR 05000454/1985047 + (ML20138L093)
- ML20138L094 + (ML20138L094)
- ML20138L101 + (ML20138L101)
- ML20138L106 + (ML20138L106)
- ML20138L109 + (ML20138L109)
- ML20138L110 + (ML20138L110)
- ML20138L111 + (ML20138L111)
- ML20138L112 + (ML20138L112)
- 05000341/LER-1985-030, :on 850701,at 2% Power,Reactor Scram Occurred. Caused by Procedural Error Resulting in Spurious Water Level 3 Signal Generation.Instrumentation & Control Technician Training Enhanced to Prevent Recurrence + (ML20138L114)
- ML20138L115 + (ML20138L115)
- ML20138L117 + (ML20138L117)
- IR 05000529/1985041 + (ML20138L118)
- ML20138L123 + (ML20138L123)
- ML20138L124 + (ML20138L124)
- ML20138L126 + (ML20138L126)
- ML20138L127 + (ML20138L127)
- ML20138L129 + (ML20138L129)
- 3F1085-14, Summarizes Programs & Improvements to Emergency Feedwater Sys for Facility.Sys Installed Which Can Automatically Start & Control Emergency Feedwater Sys & Prevent Overcooling + (ML20138L130)
- PNO-III-85-095C, on 851212,diesel Generator 14 Tripped on Low Lube Oil Pressure During Test Run.Bearing Failure & Erratic Behavior of Svc Water Pump Under Investigation as Possible Causes.Generator Will Be Monitored + (ML20138L131)
- ML20138L134 + (ML20138L134)
- ML20138L137 + (ML20138L137)
- ML20138L138 + (ML20138L138)
- ML20138L140 + (ML20138L140)
- ML20138L141 + (ML20138L141)
- ML20138L143 + (ML20138L143)