- IR 05000498/1985008 + (ML20136E661)
- ML20136E662 + (ML20136E662)
- 05000286/LER-1985-007-01, :on 851015,main Turbine Generator Trip Initiated Automatically by Signal from Main Turbine High Pressure Control Oil Sys.Caused by Blockage of Control Oil Strainers & Orifices.Strainer Cleaned + (ML20136E663)
- ML20136E665 + (ML20136E665)
- 05000255/LER-1985-022, :on 851015 & 16,primary Coolant Sys Leak Calculation Identified Excessive Leakage Resulting in Plant Shutdown.Caused by Faulty Packing on Isolation Valve MOV 3015.Addl Packing Installed + (ML20136E667)
- ML20136E669 + (ML20136E669)
- ML20136E672 + (ML20136E672)
- ML20136E674 + (ML20136E674)
- ML20136E675 + (ML20136E675)
- ML20136E676 + (ML20136E676)
- ML20136E679 + (ML20136E679)
- 05000458/LER-1985-013, :on 851012,remote Shutdown Panel Dc Power Supply in Main Control Room Located.Caused by Design Deficiency.Mod Request Initiated to Utilize Alternate Power Supply Outside Main Control Room + (ML20136E681)
- ML20136E683 + (ML20136E683)
- ML20136E685 + (ML20136E685)
- ML20136E686 + (ML20136E686)
- ML20136E688 + (ML20136E688)
- ML20136E692 + (ML20136E692)
- ML20136E693 + (ML20136E693)
- ML20136E694 + (ML20136E694)
- ML20136E696 + (ML20136E696)
- 05000458/LER-1985-015, :on 851013,Channels a & B of Control Room Ventilation Local Intake Radiation Monitors Discovered Inoperable.Caused by Sample Pump Trip Following Offsite Power Excursion.Pumps Restarted + (ML20136E697)
- ML20136E699 + (ML20136E699)
- ML20136E700 + (ML20136E700)
- ML20136E702 + (ML20136E702)
- ML20136E703 + (ML20136E703)
- ML20136E705 + (ML20136E705)
- IA-85-719, Responds to FOIA Request for Four Categories of Records Re Nuclear & Fossil Fuel Power Plants.Nrc Has No Jurisdiction Over Fossil Fuel Plants.Info Re Nuclear Plants Contained in NUREG-0020.NUREG May Be Purchased at Listed Address + (ML20136E706)
- ML20136E706 + (ML20136E706)
- ML20136E708 + (ML20136E708)
- ML20136E710 + (ML20136E710)
- ML20136E711 + (ML20136E711)
- ML20136E712 + (ML20136E712)
- IA-85-701, Responds to FOIA Request for Transcript of Commission 850603 Briefings Which Preceded Licensing Hearing for Plant. Portions of Transcript Withheld (Ref FOIA Exemptions 5 & 7). Remaining Portions Available in PDR + (ML20136E714)
- ML20136E714 + (ML20136E714)
- ML20136E715 + (ML20136E715)
- ML20136E718 + (ML20136E718)
- ML20136E723 + (ML20136E723)
- IA-84-926, Responds to FOIA Request,Confirming 851001 Telcon Which Advised That NRC 850705 Response to 841214 FOIA Request Re Plant Final + (ML20136E723)
- ML20136E727 + (ML20136E727)
- ML20136E728 + (ML20136E728)
- ML20136E729 + (ML20136E729)
- ML20136E731 + (ML20136E731)
- ML20136E734 + (ML20136E734)
- ML20136E735 + (ML20136E735)
- ML20136E737 + (ML20136E737)
- ML20136E738 + (ML20136E738)
- ML20136E741 + (ML20136E741)
- 05000249/LER-1985-023-05, :on 851017,reactor Tripped on Reactor Vessel Low Water Level Scram.Caused by Reactor Operator Error. Procedure Describing Operation & Balance of Feedwater Controllers Written + (ML20136E745)