- B11867, Informs That Test Conducted to Verify Closing of PORV Valve During Recent Hot Functional Testing Satisfied Requirements of NUREG-0737,Item II.D.1,in Response to Recent NRC Request + (ML20136D322)
- 05000382/LER-1985-046, :on 851017,fire Watch Irregularities Discovered When Fire Watch Log Compared to Security Cardreader Computer Access History Printout.Caused by Individual Not Performing Assigned Fire Watch Consistent W/Tech Specs + (ML20136D325)
- ML20136D328 + (ML20136D328)
- ML20136D330 + (ML20136D330)
- 05000254/LER-1985-017-08, :on 851015,RCIC Pump Discharge Valve Mo 1-1301-48 Would Not Open from Control Room After Closure. Caused by Dirty Main Contactor in Breaker.Main Contactor Will Be Cleaned But Not Lubricated in Future + (ML20136D334)
- ML20136D336 + (ML20136D336)
- ML20136D337 + (ML20136D337)
- 05000323/LER-1985-019-01, :on 851127,blown Fuse Discovered on Solenoid Valve SV-306 During post-safety Injection Review.Caused by Wiring Error.Short Cause of Previous Fuse Failures on 850814 & 29.Wiring Error Corrected + (ML20136D342)
- NUREG/CR-4025, Preliminary Review of Cost Analysis Contained in NUREG/CR-4025 Concerning Proposed Design Mods to Gessar + (ML20136D345)
- ML20136D345 + (ML20136D345)
- ML20136D347 + (ML20136D347)
- ML20136D348 + (ML20136D348)
- ML20136D352 + (ML20136D352)
- ML20136D355 + (ML20136D355)
- ML20136D357 + (ML20136D357)
- ML20136D363 + (ML20136D363)
- ST-HL-AE-1550, Final Deficiency Rept Re Improper Consideration of Prying Action for Pipe Support Anchorage.Initially Reported on 850524. Pipe Support Engineers Trained in Application of Std Base Plates & Prying Action Criteria.Calculations Reviewed + (ML20136D372)
- ML20136D376 + (ML20136D376)
- B11933, Forwards Technical Justification Showing That 3% of Fuel Rods Experienced DNB After Reactor Coolant Pump Rotor Seizure Event,Per SER + (ML20136D377)
- ML20136D380 + (ML20136D380)
- ML20136D390 + (ML20136D390)
- IR 05000354/1985047 + (ML20136D391)
- ML20136D400 + (ML20136D400)
- 05000285/LER-1985-010, :on 851122,LPSI Pump SI-1A Failed to Start When Given Start Signal from Automatic Sequencer.Caused by Failure of GE Hea Relay Contact.Defective Contact Movable Arm Bent to Make Contact Per GE Maint Manual + (ML20136D401)
- ML20136D405 + (ML20136D405)
- ML20136D410 + (ML20136D410)
- ML20136D427 + (ML20136D427)
- ML20136D428 + (ML20136D428)
- ML20136D432 + (ML20136D432)
- ML20136D435 + (ML20136D435)
- RBG-22-859, Corrected Ltr Forwarding Rept Containing Brief Description of Changes to Initial Test Program & Summary of Safety Evaluation for Each Change. Rept Provided Per License NPF-47,Section 2.C(12) + (ML20136D436)
- W3P85-3158, Forwards Response to Generic Ltr 83-28,Items 2.2.1,2.2.2 & 3.2 Re Equipment Classification,Vendor Interface Program & post-maint Testing of safety-related Components, Respectively,Per License Condition 13 + (ML20136D439)
- ML20136D441 + (ML20136D441)
- ML20136D443 + (ML20136D443)
- 05000331/LER-1985-046, :on 851120,electric Fire Pump Out of Svc for More than 7 Days & Maint Not Completed.Caused by Increased Scope of Work & Delay in Procurement of Parts.Electric Pump Returned to Svc & Pump Tested + (ML20136D452)
- ML20136D456 + (ML20136D456)
- ML20136D462 + (ML20136D462)
- ML20136D464 + (ML20136D464)
- 05000499/LER-1997-001-01, :on 970205,main Steam Safety Valve Setpoints Discovered Outside Required Tolerance Occurred.Caused by MSSV Above & Beyond Previously Documented Setpoint Drift. Lift Setting of Five MSSV Were Adjusted + (ML20136D468)
- 05000254/LER-1985-097, :on 851125,diesel Fire Pump B Out of Svc for Repair Greater than 7 Days.Caused by Rings Worn to Point That Tolerances Out of Spec.Pump Overhauled & Wear Rings Replaced + (ML20136D474)
- ML20136D476 + (ML20136D476)
- ML20136D478 + (ML20136D478)
- ML20136D483 + (ML20136D483)
- ML20136D484 + (ML20136D484)
- IR 05000373/1985032 + (ML20136D488)
- ML20136D493 + (ML20136D493)
- ML20136D496 + (ML20136D496)
- ML20136D501 + (ML20136D501)
- B11913, Forwards Listed Encls,Including Current Emergency Operating Procedures,In Response to 851017 Request Re Use of Feed & Bleed in Environ Qualification of Equipment Outside Containment + (ML20136D506)
- ML20136D508 + (ML20136D508)
- ML20136D511 + (ML20136D511)