List of results
- 05000341/LER-1985-038, :on 850713,HPCI/RCIC Surveillance Tests Not Performed within 12 H Time Limit Prescribed by Tech Specs. Caused by Omission of Tests in General Operating Procedures. Procedural Deficiencies Corrected + (ML20134D858)
- ML20134D863 + (ML20134D863)
- ML20134D864 + (ML20134D864)
- 3F1096-22, Special Rept:On 960902,unit Shutdown Due to Leak in Turbine Lube Oil Sys.Issue Will Be Resolved Before Startup from Current Outage + (ML20134D867)
- 05000454/LER-1985-066, :on 850712,operating Temp Delta T Trip Setpoint Exceeded During Load Rejection Testing,Causing Reactor Trip & Control Room Ventilation Makeup Fan auto-start.Caused by Inaccurate Stroke Times of Steam Dump Valves + (ML20134D868)
- B15938, Provides NRC W/Status of Readiness of Plant to Proceed to Mode 6 Operation + (ML20134D870)
- ML20134D871 + (ML20134D871)
- ML20134D874 + (ML20134D874)
- ML20134D875 + (ML20134D875)
- ML20134D879 + (ML20134D879)
- 05000528/LER-1985-042, :on 850711,identified RCS Leak Rate of 1.28 Gpm,Exceeding 1.0 Gpm Limit.Plant Shut Down Per Tech Spec 3.4.5.2.b.Caused by Miscalculation of Leak Rate Due to Procedural Deficiency.Procedure Improved + (ML20134D881)
- NSD-NRC-96-4857, Forwards Responses to NRC Mechanical Engineering Branch Questions Including high-energy Line Break + (ML20134D882)
- NSD-NRC-96-4856, Responds to RAI on AP600 Design Certification Program + (ML20134D885)
- NSD-NRC-96-4858, Forwards Suppl Info on AP600 Radioactive Waste Mgt Sys Design + (ML20134D887)
- ML20134D888 + (ML20134D888)
- 05000155/LER-1997-001, :on 970102,containment Sphere Integrated Leakage Rate Test Was Not Performed IAW App J to 10CFR50. Caused Because TV-02 Did Not Provide Adequate Guidance for Control of Test.Blind Flange Was Removed + (ML20134D889)
- ML20134D892 + (ML20134D892)
- ML20134D893 + (ML20134D893)
- ML20134D897 + (ML20134D897)
- ML20134D902 + (ML20134D902)
- PNO-III-97-007, on 970205,identified Missing Devices & Contamination Events at Facility.Licensee Tracking Serial Number of Missing Source to Determine Present Location of Source.Other Affected States Will Be Notified + (ML20134D905)
- ML20134D906 + (ML20134D906)
- 05000454/LER-1985-068, :on 850713,lightning Strike Resulted in Reactor Trip & Damage to Listed Train B Safeguards Instrumentation. Caused by Induced Voltage Transient on Station Ground & Rod Drive Power Failures.Lightning Sys Mods Made + (ML20134D907)
- 05000482/LER-1996-011-01, Forwards LER 96-011-01,96-012-01,96-013-01,96-014-01, 96-015-01 & 96-016-01 + (ML20134D911)
- ML20134D914 + (ML20134D914)
- ML20134D916 + (ML20134D916)
- ML20134D918 + (ML20134D918)
- ML20134D919 + (ML20134D919)
- ML20134D920 + (ML20134D920)
- ML20134D921 + (ML20134D921)
- 05000271/LER-1996-031, :on 961009,alternate Rod Insertion Recirculation Pump Trip Occurred Due to Inadvertent False Low Water Level Signal on Level Transmitter During Backfill of Ref Leg.Scram & Ari/Rpt Reset + (ML20134D922)
- ML20134D924 + (ML20134D924)
- ML20134D925 + (ML20134D925)
- ML20134D927 + (ML20134D927)
- IA-85-512, Responds to FOIA Request for List of Names & Addresses of Companies Licensed to Store,Handle or Process Radioactive Matls.Forwards Computer Printout.W/O Encl + (ML20134D927)
- ML20134D928 + (ML20134D928)
- ML20134D931 + (ML20134D931)
- ML20134D934 + (ML20134D934)
- ML20134D935 + (ML20134D935)
- ML20134D941 + (ML20134D941)
- ML20134D943 + (ML20134D943)
- ML20134D946 + (ML20134D946)
- ML20134D947 + (ML20134D947)
- ML20134D948 + (ML20134D948)
- ML20134D950 + (ML20134D950)
- ML20134D953 + (ML20134D953)
- ML20134D955 + (ML20134D955)
- ML20134D960 + (ML20134D960)
- ML20134D961 + (ML20134D961)
- NSD-NRC-96-4865, Forwards Rev 2,Volumes 1-4 to WCAP-13275, AP600 PRA Fault Trees + (ML20134D963)
- 05000368/LER-1985-013, :on 850708,weekly Channel Check of in-core Detector Sys Found Not Performed on 850703.Caused by Administrative Oversight.Check Completed & Schedule Included in Util Tracking Sys + (ML20134D964)