- 05000388/LER-1985-015-01, :on 850421,spray Pond Bypass Valve HV-01222A Did Not Automatically Open When Emergency Svc Water Pump a Started.Caused by Two Open Sliding States Link Terminal Blocks in Relay Panel.Links Evaluated + (ML20129B428)
- ML20129B430 + (ML20129B430)
- ML20129B432 + (ML20129B432)
- 05000315/LER-1985-023, :on 850502,definition of Auxiliary Bldg Crane Load Block as Being Heavy Load Not Emphasized in Plant Procedures.Cautions Will Be Added to Applicable Plant Procedures by 850615 + (ML20129B433)
- ML20129B434 + (ML20129B434)
- ML20129B435 + (ML20129B435)
- ML20129B436 + (ML20129B436)
- 05000454/LER-1985-048, :on 850424,radiation Monitor OPR32J in Main Control Room Outside Air Intake a Went Into Interlock Mode, Causing Train a of Ventilation Sys to Transfer to ESF Configuration.Caused by Dirty Filter + (ML20129B437)
- ML20129B438 + (ML20129B438)
- ML20129B439 + (ML20129B439)
- ML20129B440 + (ML20129B440)
- ML20129B441 + (ML20129B441)
- ML20129B443 + (ML20129B443)
- ML20129B444 + (ML20129B444)
- ML20129B446 + (ML20129B446)
- RBG-20961, Interim Deficiency Rept DR-295 Re AKD-6 480-volt Switchgear Supplied by Ge.Next Rept Will Be Submitted by 850530 + (ML20129B449)
- IR 05000309/1985009 + (ML20129B452)
- ML20129B455 + (ML20129B455)
- IR 05000373/1996009 + (ML20129B457)
- ML20129B459 + (ML20129B459)
- ML20129B460 + (ML20129B460)
- ML20129B461 + (ML20129B461)
- ML20129B462 + (ML20129B462)
- ML20129B463 + (ML20129B463)
- 2CAN058505, Forwards Description of Missed Surveillances Re Inservice Testing Program for Check Valve,Per 850408 Agreement.Review Indicates No Reduction of Safety During Cycle 4 Operation + (ML20129B464)
- IR 05000454/1985029 + (ML20129B467)
- ML20129B469 + (ML20129B469)
- IR 05000267/1985012 + (ML20129B471)
- ML20129B473 + (ML20129B473)
- ML20129B474 + (ML20129B474)
- ML20129B476 + (ML20129B476)
- ML20129B478 + (ML20129B478)
- ML20129B479 + (ML20129B479)
- ML20129B481 + (ML20129B481)
- ML20129B482 + (ML20129B482)
- ML20129B483 + (ML20129B483)
- ML20129B484 + (ML20129B484)
- ML20129B486 + (ML20129B486)
- 05000281/LER-1985-003-03, :on 850428,Type C Testing Revealed Both Outside Recirculation Spray Pump Suction Valves MOV-RS-255A, B(Eiis 20) Inoperable.On 850510,outside Recirculation Spray Pump Discharge Valve Inoperable + (ML20129B491)
- ML20129B492 + (ML20129B492)