Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- 05000270/LER-1979-009-01, /01T-0:on 791209,during Annual Maint of Engineered Safeguard Valves,Hpi Suction Valves from Borated Water Storage Tank Rendered Inoperable.Caused by Inadvertent Removal & Cleaning of Limit Switch Assemblies + (ML20125B712)
- U-600072, Forwards Draft Proposed FSAR Rev Re Effects of Jet Impingement & Justification for Exceptions to Srp,Per SER Outstanding Issue 5.NUREG/CR-2913 Used for Certain Jet Analyses + (ML20125B713)
- ML20125B714 + (ML20125B714)
- ML20125B715 + (ML20125B715)
- ML20125B716 + (ML20125B716)
- 05000334/LER-1979-040-99, /99X-0:on 790920,during Operational Mode 3,vital Bus Inverter 4 Transferred from Auxiliary Power Source to Inverter.Inverter Was Inoperable & Safety Injection Occured. Caused by Operator Error.Personnel Reprimanded + (ML20125B717)
- ML20125B719 + (ML20125B719)
- ML20125B720 + (ML20125B720)
- ML20125B721 + (ML20125B721)
- ML20125B722 + (ML20125B722)
- ML20125B724 + (ML20125B724)
- ML20125B725 + (ML20125B725)
- ML20125B726 + (ML20125B726)
- ST-HL-AE-1268, Forwards Revised FSAR Questions & Responses Re Diesel Generators & Lighting Sys.Revised Info Will Be Incorporated Into FSAR Amend 49 + (ML20125B727)
- ML20125B728 + (ML20125B728)
- ML20125B729 + (ML20125B729)
- ML20125B730 + (ML20125B730)
- ML20125B731 + (ML20125B731)
- ML20125B732 + (ML20125B732)
- ML20125B734 + (ML20125B734)
- ML20125B735 + (ML20125B735)
- ML20125B736 + (ML20125B736)
- ML20125B737 + (ML20125B737)
- W3P85-1058, Notifies That Design & Procedural Mods Re Fire Watch at Isolation Panel in Relay Room of Reactor Auxiliary Bldg Complete.Fire Watch Terminated on 850531 + (ML20125B739)
- ML20125B741 + (ML20125B741)
- ML20125B742 + (ML20125B742)
- ML20125B743 + (ML20125B743)
- ML20125B744 + (ML20125B744)
- ML20125B745 + (ML20125B745)
- ML20125B746 + (ML20125B746)
- ML20125B747 + (ML20125B747)
- ML20125B748 + (ML20125B748)
- ML20125B750 + (ML20125B750)
- ML20125B751 + (ML20125B751)
- ML20125B755 + (ML20125B755)
- HL-3044, Responds to NRC Re Violations Noted in Insp Repts 50-321/92-22 & 50-366/92-22.Corrective Actions:Design Change Will Be Implemented by 930531 to Remove Ability to Override Automatic Isolation Function for Dampers + (ML20125B756)
- ML20125B757 + (ML20125B757)
- ML20125B760 + (ML20125B760)
- ML20125B762 + (ML20125B762)
- ML20125B763 + (ML20125B763)
- ML20125B764 + (ML20125B764)
- ML20125B765 + (ML20125B765)
- ML20125B766 + (ML20125B766)
- ML20125B767 + (ML20125B767)
- ML20125B769 + (ML20125B769)
- ML20125B773 + (ML20125B773)
- ML20125B774 + (ML20125B774)
- ML20125B775 + (ML20125B775)
- 05000333/LER-1992-047, :on 921104,automatic Shutdown Cooling Occurred Due to Loss of Power to Rps.Caused by Voltage Drop When Starting Large Electrical Load.Protective Device Setpoint Will Be Evaluated + (ML20125B776)
- ML20125B778 + (ML20125B778)
- ML20125B779 + (ML20125B779)