Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- NRC-84-2985, Advises That Addl Info Requested During 841008 Meeting Re WCAP-9172(P)/9264(NP), N-16 Transit Time Flow Measurement Sys (Ttfm) Description & Performance Will Be Provided to NRC by First Refueling Outage + (ML20108F290)
- ML20108F295 + (ML20108F295)
- TXX-4434, Interim Significant Deficiency Rept SDAR-169 Re Environmentally Unqualified Sump Isolation Valve Motors for Svc Conditions Per IEEE-323.Initially Reported on 850215. Evaluation Expected to Be Completed by 850529 + (ML20108F302)
- ML20108F304 + (ML20108F304)
- ML20108F309 + (ML20108F309)
- ML20108F312 + (ML20108F312)
- ML20108F317 + (ML20108F317)
- RBG-20317, Final Deficiency Rept DR-282 Re Lack of anti-siphon Device in Spent Fuel Cooling Lines in Containment & Fuel Bldgs. Initially Reported on 850201.Anti-siphoning Holes Drilled as Required by Sys Design Drawings + (ML20108F321)
- ML20108F323 + (ML20108F323)
- ML20108F337 + (ML20108F337)
- ML20108F343 + (ML20108F343)
- ML20108F349 + (ML20108F349)
- ML20108F350 + (ML20108F350)
- ML20108F352 + (ML20108F352)
- 05000333/LER-1985-003, :on 850205,emergency Diesel Generators a & C & Emergency Svc Water Pump a Declared Inoperable When Pump Tripped During Startup for Routine Surveillance.On 850207, Pump Tripped on Overcurrent During Startup + (ML20108F360)
- 05000352/LER-1985-015, :on 850118,sprinkler Sys for Cable Spreading Room Inoperable W/O Continuous Fire Watch.Caused by Inadequate Procedure for Hydrostatic Testing & Personnel Error.Procedure Issued & Personnel Counseled + (ML20108F362)
- LD-84-074, Forwards Summary Rept on Design Basis of Shutdown Cooling Sys Relief Valves for CESSAR Sys 80 & Summary Rept on Operability of Shutdown Cooling Sys Relief Valves for Palo Verde Units 1,2 & 3, Per 841109 Meeting + (ML20108F367)
- ML20108F372 + (ML20108F372)
- ML20108F374 + (ML20108F374)
- ML20108F380 + (ML20108F380)
- 05000267/LER-1984-009, :on 840726,analysis of Sump Sample Indicated Concentration of Unknown Beta Emitters Above Max Permissible Concentration Limit.Caused by Release of Dye Into Floor Drains.Drains Plugged W/Inflatable Plugs + (ML20108F383)
- ML20108F387 + (ML20108F387)
- ST-HL-AE-1192, Forwards Interim Security Plan to Support Receipt of Fuel at Site.Plan Will Provide Security for Reactor Fuel Until Util Plan Implemented.W/O Encl + (ML20108F391)
- BSEP-85-0287, Special Rept 1-SR-85-1:on 850128,7-day Fire Barrier Limiting Condition for Operation Exceeded for Fire Door 117 of Unit 1 Battery Room B & Fire Door 113 of Unit 2 Battery Room B to Maintain Acceptable Room Temps + (ML20108F393)
- ML20108F397 + (ML20108F397)
- ML20108F405 + (ML20108F405)
- ML20108F408 + (ML20108F408)
- ML20108F409 + (ML20108F409)
- ML20108F413 + (ML20108F413)
- ML20108F416 + (ML20108F416)
- 05000397/LER-1985-001, :on 850111,existence of 10CFR21 Condition Determined Due to Nonconservative Engineering Assumptions Associated W/Calculating Environ Profiles Used to Qualify Reactor Bldg Equipment + (ML20108F422)
- ST-HL-AE-5357, Forwards Endorsements 18,16,55 & 14 to Certificates N-113, N-116,N-307 & NW-199 & Endorsements 20,19,46 & 19 to Maelu Certficates M-113,M-116,MF-130 & MW-100 + (ML20108F428)
- ML20108F429 + (ML20108F429)
- RBG-20318, Final Deficiency Rept DR-188 Re Defective Hubs on Socket Flanges Supplied by West Jersey Mfg Co.Initially Reported on 850201.Flanges in Question Discarded + (ML20108F431)
- ML20108F433 + (ML20108F433)
- ML20108F437 + (ML20108F437)
- ML20108F438 + (ML20108F438)
- ML20108F444 + (ML20108F444)
- RBG-20307, Final Deficiency Rept DR-264 Re Physical Separation Between Div I & Div II Panel Wiring in Remote Shutdown Panel C61-P001 Supplied by Ge.Condition Not Reportable Per 10CFR50.55(e) + (ML20108F445)
- 05000333/LER-1985-004, :on 850212,one of Two Reactor Bldg Pressure Suppression Chamber Vacuum Breaker Valves Made Inoperable & Remained Inoperable in Excess of Tech Specs.Caused by Restriction by Scaffolding + (ML20108F446)
- ML20108F453 + (ML20108F453)
- ML20108F454 + (ML20108F454)
- ML20108F457 + (ML20108F457)
- ML20108F462 + (ML20108F462)
- ML20108F467 + (ML20108F467)
- ML20108F479 + (ML20108F479)
- 05000331/LER-1985-004, :on 850202,reactor Protection Sys Trip Occurred Due to APRM Upscale Trip.Caused by Shorted LPRM W/Common Inputs to APRM Channels a & B.Investigation to Determine Failure Mod Begun + (ML20108F483)
- ML20108F484 + (ML20108F484)
- ML20108F489 + (ML20108F489)
- ML20108F490 + (ML20108F490)
- ST-HL-AE-1161, Forwards Amend 43 to FSAR for South Texas Project + (ML20108F493)