- 05000388/LER-1985-007, :on 850129,RHR Sys Shutdown Cooling Suction Valve Closed Unexpectedly.Cause Not Stated.Pressure Switch Checked & Shutdown Cooling Established.Switch May Be Replaced Pending Evaluation + (ML20108E052)
- ML20108E054 + (ML20108E054)
- ML20108E057 + (ML20108E057)
- ML20108E061 + (ML20108E061)
- ML20108E062 + (ML20108E062)
- ML20108E066 + (ML20108E066)
- ML20108E071 + (ML20108E071)
- ML20108E074 + (ML20108E074)
- ML20108E082 + (ML20108E082)
- NSD-NRC-96-4708, Provides Recommended Wording for Section 2.0,Items 6 & 8 Re South Tx SE for NRC Bulletin 88-008 for Proprietary Aspects + (ML20108E088)
- ML20108E092 + (ML20108E092)
- ML20108E098 + (ML20108E098)
- ML20108E099 + (ML20108E099)
- ML20108E104 + (ML20108E104)
- ML20108E113 + (ML20108E113)
- ML20108E116 + (ML20108E116)
- ML20108E117 + (ML20108E117)
- ML20108E122 + (ML20108E122)
- ML20108E123 + (ML20108E123)
- ML20108E126 + (ML20108E126)
- ML20108E134 + (ML20108E134)
- W3P84-3458, Informs That FSAR Will Be Updated to Reflect Current ASME Section III Winter 1981 Addenda Commitment for Essential Chilled Water Sys & Component Cooling Water Sys Piping + (ML20108E141)
- ML20108E153 + (ML20108E153)
- ML20108E157 + (ML20108E157)
- ML20108E161 + (ML20108E161)
- ML20108E163 + (ML20108E163)
- ML20108E167 + (ML20108E167)
- ML20108E181 + (ML20108E181)
- ML20108E186 + (ML20108E186)
- ML20108E191 + (ML20108E191)
- ML20108E193 + (ML20108E193)
- ML20108E207 + (ML20108E207)
- ML20108E216 + (ML20108E216)
- B11474, Forwards Amend 12 to FSAR for Millstone Unit 3.Revised Responses to Selected Requests for Addl Info,Per 830503,31 & 1203 Ltrs,Included + (ML20108E220)
- 05000237/LER-1985-005-04, :on 850130,Group II Isolation Occurred While Returning Level Transmitter 2-263-S8B to Svc.Cause Under Investigation.Supplemental Rept Will Be Issued When Root Cause Determined + (ML20108E238)
- ML20108E249 + (ML20108E249)
- ML20108E297 + (ML20108E297)
- BECO-85-051, Suppl Response to NUREG-0803, Generic SER Re Integrity of BWR Scram Sys Piping. Seismic Reanalysis of Scram Discharge Vols Performed.Updates to Isometrics to Reflect as-built Configuration Expected by 850401 + (ML20108E299)
- ML20108E317 + (ML20108E317)
- ML20108E319 + (ML20108E319)
- ML20108E325 + (ML20108E325)
- 05000271/LER-1996-009, :on 960404,determined Combustible Polystyrene Matl Present in Joints Between Turbine,Radwaste,Reactor & Control Bldgs.Caused by Personnel Error.Two H Roving Fire Watch Established in Adjoining Radwaste Bldg + (ML20108E330)
- ML20108E333 + (ML20108E333)
- ML20108E338 + (ML20108E338)
- ULNRC-03375, Responds to NRC Bulletin 96-001, Control Rod Insertion Problems + (ML20108E345)
- 05000331/LER-1996-002, :on 960408,PCIS Half Group III Isolation Occurred Due to Blown Fuse During Maint.Reviewed Event W/ Maint Technicians to Reinforce Need to Secure Loose Cables During Maint Activities + (ML20108E350)
- 05000266/LER-1996-001, :on 960405,inadvertent ESF Actuation in Train B Due to DC Sys Ground Occurred.Caused by Inadequate Ground Search Technique.Site Engineering Personnel Will Be Involved in Ground Detection Needed on DC Sys + (ML20108E351)