GEORGIA POWER COlPANY HATCH NUCLEAR PLANT PROCEDURE A

1 1

tg Noti $ cation of Unusual Event - Control Room Operators PROCEDURE TITLE HNP-4422 PROCEDURE NUMBER Lab RESPONSIBLE SECTION SAFETY RELATED ( X)

NON-SAFETY RELATED (

)

APPROVED APPROVED REV.

DESCRIPTION DEPT.

PLANT DATE HEAD MANAGER

[

2 Page 1

/d gf f z,_

D.

C/

--5e1 3

Pa

/

p V

8 t

l.

i l

l L----__-----_----.

I.

lt d

1 8412140173 841129 p.ge-9 PDR ADOCK 05000321 l'

V PDR

__m..__,m%,,,_,_,,_,,,,,,_,,,,,_,..,.,p

,,,,-..---.w_,,

..,.-.._y.,,.

g.._

APPROVAL PROCEDURE NO HNP-4422 E. l. HATCH NUCLEAR PLANT See Title Page R

No 3

care See Title Page GeorgiaPower h

p; eo 1,, 1 l

NOTIFICATION OF UNUSUAL EVENT - CONTROL ROOM OPERATORS A.

CONDITIONS Unusual events are in pro ess or have occurred which indicate a potential degradation of the level of safety of the plant, such as those noted in HNP-4420, Table 1.

No releases of radioactive material requiring offsite response or monitoring are expected unless further degradation of safety systems occurs.

B.

REFERENCE HNP-4420 C.

ACTION 1.

Take appropriate action to place the plant in a safe condition in accordance with emergency operating procedures, Tech. Specs., and annunciator response procedures.

2.

Make the following announcement over the PA:

ATTENTION, ATTENTION:

A NOTIFICATION OF UNUSUAL EVENT EXISTS.

(If immediate safety of personnel involved, state the incident.)

INITIATE NOTIFICATION OF UNUSUAL EVENT PROCEDURES.

NOTE I

There is no Gai-tronics tone for Notification of Unusual Event.

Repeat announcement.

3.

Check the control room instrumentation to determine s'atus of plant as to whether or not a more severe emergency class should be declared.

Notify Shift Supervisor of findings.

l 4.

Notify Security.

L 5.

Evaluate radiological releases using HNP-4853 and inform l

Shift Supervisor of results.

6.

If Shift Supervisor has not reported in to the control room, l

initiate his actions as per F9F-4423.

7.

Announcement of the " Notification of an Unusual Event" O

status should be repeated periodically (approximately every 30 minutes) throughout the duration of the event.

l l

...m.--m

-