- 05000244/LER-1984-012, :on 841005,insp of Auxiliary Bldg Exhaust Fan 1c Ductwork Revealed Discharge Damper Not Cycling W/Actuator Arm.Cause Not Stated.Stopwork for All Fuel Handling Issued Until Damper Repaired + (ML20108A958)
- ML20108A960 + (ML20108A960)
- ML20108A967 + (ML20108A967)
- 2CAN049604, Responds to NRC Questions Re Containment Air Lock TS Change Request + (ML20108A969)
- ML20108A971 + (ML20108A971)
- ML20108A972 + (ML20108A972)
- ML20108A975 + (ML20108A975)
- ML20108A976 + (ML20108A976)
- ML20108A984 + (ML20108A984)
- ML20108A986 + (ML20108A986)
- ML20108A988 + (ML20108A988)
- ST-HL-AE-5356, 1995 Annual Environ & Annual Radiological Environ Repts STP Electric Generating Station + (ML20108A990)
- ML20108A998 + (ML20108A998)
- ML20108B003 + (ML20108B003)
- ML20108B004 + (ML20108B004)
- ML20108B018 + (ML20108B018)
- L-96-116, Forwards Rev 9 to Physical Security Plan,Including Summary of Changes,Revised List of Effective Pages & Completely Retyped of Rev 9 of Plan.Encl Withheld,Per 10CFR2.790(a)(3) + (ML20108B025)
- ML20108B027 + (ML20108B027)
- ML20108B042 + (ML20108B042)
- ML20108B052 + (ML20108B052)
- ML20108B053 + (ML20108B053)
- ML20108B075 + (ML20108B075)
- ML20108B087 + (ML20108B087)
- 05000220/LER-1984-016, :on 841001,momentary Grid Disturbance Occurred Producing Dip in 115 V Transmission Line Causing Frequency Relays to Trip.Caused by Oswego Steam Station Attempting to Put Syncronous Condenser in Svc + (ML20108B096)
- ML20108B098 + (ML20108B098)
- ML20108B113 + (ML20108B113)
- ML20108B117 + (ML20108B117)
- ML20108B118 + (ML20108B118)
- 05000397/LER-1984-108, :on 841006,licensed Operator Placed Reactor Mode Switch in Run Mode.Procedure Performed Out of Sequence, Prior to Ensuring Pressure at Rated Conditions.Operators Briefed on Procedures + (ML20108B135)
- ML20108B145 + (ML20108B145)
- 05000397/LER-1984-107, :on 841008,control Room Emergency Filtration Sys Fan Automatically Started on Hi Chlorine Signal.Caused by Optics Indicating Lamp Backing Out of Socket,Cutting Off Light to Photo Cells.Light Tightened + (ML20108B149)
- ML20108B162 + (ML20108B162)
- PLA-2330, Monthly Operating Repts for Sept 1984 + (ML20108B166)
- ML20108B168 + (ML20108B168)
- ML20108B170 + (ML20108B170)
- ML20108B173 + (ML20108B173)
- ML20108B178 + (ML20108B178)
- 05000285/LER-1996-002, :on 960329,reactor Manually Tripped Due to Partial Loss of Vacuum in Main Condenser.Condenser Isolated, Plant Shutdown & Leaking Condenser Tube Plugged.Pm Order WP-006820 Will Be Revised + (ML20108B194)
- 05000395/LER-1996-003, :on 960206,identified Discrepancy in Test Methodologies Between TS Required Testing & Actual Testing Performed.Caused by Recognize Discrepancy in Test Methodologies.Emergency TS Change Requested + (ML20108B195)
- 05000366/LER-1984-022, :on 841006,motor Leads Disconnected to RHR Svc Water Pumps 1E11-COO1B & 1E11-COO1D.Caused by Personnel Error.Personnel Counseled + (ML20108B203)
- ML20108B205 + (ML20108B205)
- 05000366/LER-1984-010, :on 840924,reactor Water Cleanup (RWCU) Inboard & Outboard Isolation valves,2G31-F001 & 2G31-F004, Respectively,Isolated Due to High Differential Flow Signal. Caused by RWCU Demineralizer Not Full + (ML20108B211)
- 05000373/LER-1984-075, On 841111,leak Discovered in Thermowell 1B33-NO 23B.Caused by Mechanical Fatigue Due to Turbulent Flow Conditions.Thermowell & Resistance Temp Device Replaced.Insp Will Be Performed During Outage + (ML20108B213)
- W3P84-2968, Final Significant Const Deficiency Rept SCD-108 Re Failure to Comply W/Fsar Safe Shutdown Commitment.Initially Reported on 840928.Mods to Protect Essential Cables from Effects of Cable Vault Fire Complete + (ML20108B219)
- ML20108B235 + (ML20108B235)
- 05000259/LER-1996-002-02, :on 960328,EDG auto-started Due to Undervoltage Condition as Result of Personnel Error.Functional Tests on Breakers Associated W/Shutdown Bus Stopped & EDG Shutdown & Placed in Standby Readiness + (ML20108B252)
- 05000271/LER-1985-002, :on 850128,discovered That Quarterly Calibr Test of LPCI Low Reactor Pressure Channel 3 Not Performed.Caused by Personnel Anticipating Approval of Amend to Tech Specs,Changing Calibr Frequency + (ML20108B255)
- ML20108B272 + (ML20108B272)
- ML20108B273 + (ML20108B273)
- ML20108B277 + (ML20108B277)
- 05000305/LER-1984-013, :on 840702,auxiliary Bldg Special Ventilation Sys Train B Ran for Unknown Reason.Cause Later Identified as Burned Out Coil on Johnson Solenoid Valve.Valves Will Be Replaced + (ML20108B278)