ML20108B118

From kanterella
Jump to navigation Jump to search
Forwards Groundwater Monitoring Rept for Catawba Nuclear Station Conventional Wastewater Treatment Ponds from Samples Collected on 960304
ML20108B118
Person / Time
Site: Catawba  
Issue date: 04/23/1996
From: Carter J
DUKE POWER CO.
To: Hursey S
SOUTH CAROLINA, STATE OF
References
NUDOCS 9605030164
Download: ML20108B118 (5)


Text

.

,2h, c ci.

.a.;.._...,

~~

~

-.~

Nh i

DukeIbuer Cornieny ElectricSysten Support 01Dllagersl'erryIbad Huntersville, NC18M19B DUKEPOWER April 23,1996 Ms. Sandra Hursey SC Department of Health and Environmental Control Bureau of Water Pollution Control Water Quality Assessment and Enforcement Section 2600 Bull Street Columbia, South Carolina 29201

Subject:

Catawba Nuclear Station - NPDES Permit # SC0004278 WC Pond Groundwater Monitoring Data File Code: CN-705.05 Certified Mail: 2 403 319137

Dear Ms. Hursey:

Please find attached a groundwater monitoring report for Catawba Nuclear Station's conventional wastewater treatment ponds. Samples were collected on March 4,1996 in accordance with the sampling and analysis plan.

All monitoring results met the South Carolina State groundwater standards, The sulfate concentration seen in the upgradient well WCMW1 continues to remain high.

Should you have questions or comments regarding this report please contact John Estridge at (704) 875-5965.

Sincerely b-ohn C rter, echnical System Manager nvironmental Division, Water Protection jte/529 Q30

~.

Attachments l

\\

Catawba District Hydrologist xc:

.CNSMLQPjs,1dhudp2LIJst,

~

l 9605030164 960423

'5 PDR ADOCK 05000413 R

PDR n-,~,..~,,.

%4:...-...:.

-. - _ _. ~...,. _

t bc:

Reece, J. E.-CN04EM Jackson, A. P.-CNO3CH Santini, R. A.-MG03A Lascara, M. A..MG03A5 W.M. Miller - MG03C4 l

f

.n u

~

. ~ _.

w

.~u as u

DUKE POWER COMPANY April 3,1996 l-GROUND-WATER MONITORING REPORT Table 1 Facility: Catawba Nuclear Station Conventional Chemical Waste Treatment Ponds

j--

Sample Date: March 4,1996 (GEOCHEMISTRY DATA)

L Storet Monitoring WellIdentification FIELD SC R61-58 Parameter Units Number WCMW1B WCMW2 IWCMW3 WCMW4 BLANK MCL Lab Certificate No.

00008 99005 99005 99005 99005 99005 1M@IMS Top ofWell Casing mst-feet rem 622.06 608.32 600.35 595.42 MEW inMMM!Mk Depth to Water feet 3 ' 4 5nt 16.88 19.61 18.05 13.50 Ass @ee ag#inlP*W@

Water Elevation (0.01) ms!-feet 82545 605.18 588.71 582.30 581.92 $Mj@

HGME%

Well Deptla feet

%74L%Q 25.%

30.02 30.06 21.52 nGMQ FCA M E Field Spec. Candm-tawa umho/cm 00095 2199 383 123 127 i!nMPS 4sWM$fu Field pH Std. Units 00400 6.4 6.7 5.9 6.5 M**!!R 6.5-8.5" Arsenic mg/l 01002 0.012

<0.0010

<0.0010 0.0014

<0.0010 0.050 Barium mg/l 01007 0.066 0.035 0.047 0.020

<0.0050 2.0 i

Cadmium mg/l 01027 0.00015 0.00012 0.00011

<0.00010 <0.00010 0.0050 Chromium mg/l 01034 0.0052 0.0054 0.0032 0.0048 0.0011 0.10 Copper mg/l 01042 0.0070 0.0019 0.0022 0.010 0.00050 1.0*

Iron mg/l 01045 2.0 4.5 3.5 1.1

<0.010 0.3

  • i Izad mg/l 01051

<0.0020

<0.0020 0.0027

<0.0020

<0.0020 0.050 Manganese I

mg/l 01055 0.059 0.17 0.18 0.010

<0.0050 0.050" Mercury mg/l 71900

<0.00010

<0.00010

<0.00010

<0.00010 <0.00010 0.0020 l

Selenium mg/l 01147

<0.0020

<0.0010

<0.0010

<0.0010 0.0012 0.050 Silver mg/l 01077

<0 00020

<0.00020

<0.00020 0.015 <0.00020 0.10*

Sulfate mg/l 00945 1081 57 23 21

<1.0 250-Zine mg/l 01092 0.012

<0.0050

<0.0050

<0.0050

<0.0050 5.0*

  • SC R61-58.5(O) Secondary Maximum Contaminant Imel (MCL) for drinking water as reference only.

N '.

g-f ;' a,..

5.

fY.y;.

2 yp

[

q ~

(

Date: h dM Authorized Release B.

s s

.5 1..

\\

o Q

/

. bw sr c r-emd

/'

/ / \\\\.-

\\

7 s

y

)

~-

a 3/

/'"')

o O

>\\

,I o J

o

/

l

\\.$

l N o M'

h g>y; A q\\

\\

\\

s

~

,y.

l) x

,, _:94

*m j

(

'N

.c _

e

(~ _

'bN{.1.

Q

's -

3 h

pf k'#

kb*$h5g'c%,,k

$N,$$,

m seco a

a-=yn,.-

g-

//

c. =.-

p

, t,/

7"f'$

/,

~5 g h =s s.S a w =gg,pd@\\\\\\('%'k f

ss

- n.

i E2

=:2E+K v5 1

_ a

=

~

s f'/, -[

' D Nf4 I

gNUCLEN Shkhl0N

//,/

CA g

LEGENO

" m ::,

n

" "acAug WASTE CAL POND

\\

\\

,, mm + i -

a

. T.d. CHAINIOF CUSTODY RECORD

% ===

%:3hg.

q gy9; k[

U W

ANALYSIS REQUEST FORM

  • O RU ONE':

p;[*' ' CNNP: M 3D 8 >AG7FWATFrc' ANALYSES REQUESTED by bottie type-MUST NOTE PRESERVATIVE'"

575 Project Name'; L M @ W MAM (may note special DL or Method)

W - Results to/ Phone': -(' A > /"I 3:16

. Address and/or PROFS' Matrix (type of samples)/QC Leve!*:

.. NSAM No.': 4LO)tof h" ' -

Collected using

'O

~

m Sample Description sampling instructions" M

4 m

O FfE. Number Of A

- e ID

Date Time Name g

Q 3

I l

l

'l WCMW-1(%

3hlht. ONO GS I

/

I-

/

$K. I w Ma. 2 IntM r

s t'

I-wcu u.s lotX u

a i

I h; I Mc Ma. 4

!M.fD I

/

bll F aft n (Df A AJV

\\l 10'$0 O

I I

I

/

\\

l

f.."

l g

~

l I

I I

I I

l 4..

l

'e 1

$E : I 1

i MISample Preserved, Q'(g OA,_

$o ".

S 3

5,:,3 e?'e

~

\\

Total # of samples'*:

e

_7 71 wffttua

/

Delivered by:

Delivered by:

a quested'*:

Date/Rme:

Date/ Time:

O Rush (2 weeks)

'3. v / -

Received by:

Received by:

O Emergency Rush f

_ _ A,,,,,

3 O Date Results Requested

.Neq= x J NMdN "Jitammen ow _ % rw

-.