Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML20101Q553 + (ML20101Q553)
- U-602005, Advises of Change in Titles for Ms Perry & Jg Cook.Perry Title Changed to Senior vice-president & Cook Title Changed to vice-president & Manager of Facility.Correspondence List Should Be Revised to Reflect Change + (ML20101Q554)
- TXX-9227, Responds to NRC Re Deficiency/Unresolved Items Noted in Configuration Mgt Insp Repts 50-445/91-202 & 50-446/91-202 on 911118-1213.Scheduled Walkdowns Will Include Identification of Cable Tray Hangers + (ML20101Q557)
- ST-HL-AE-4141, Forwards Suppl to 911105 Response to Violations Noted in Insp Repts 50-498/91-21 & 50-499/91-21 Re Issuance of Vital Area Keys.Response Withheld + (ML20101Q560)
- 05000275/LER-1992-001, :on 920214,0608,19 & 25,plant Operated Outside of Design Basis Re App R Criteria.Caused by Personnel Error Due to Lack of Attention to Detail.Fire Watches Established, Operators Notified & Design Change Initiated + (ML20101Q563)
- ML20101Q564 + (ML20101Q564)
- ML20101Q572 + (ML20101Q572)
- ML20101Q575 + (ML20101Q575)
- ML20101Q583 + (ML20101Q583)
- 05000443/LER-1992-006, :on 920612,smoke Detector in Control Room East Air Intake Actuated High Smoke Concentration Alarm.Caused by Spurious Alarm Signal Due to Adverse Environ Conditions.Work Request Initiated to Recalibr Detector + (ML20101Q588)
- ML20101Q590 + (ML20101Q590)
- 2CAN079201, Application for Amend to License NPF-6,changing TS to Revise Containment Internal Pressure,Average Air Temp & Relative Humidity Limits in TS Figure 3.6-1 & Bases & Reduce Linear Heat Rate Limit in TS Figure 3.2-1 + (ML20101Q591)
- ML20101Q595 + (ML20101Q595)
- ML20101Q597 + (ML20101Q597)
- ML20101Q598 + (ML20101Q598)
- ML20101Q601 + (ML20101Q601)
- ML20101Q602 + (ML20101Q602)
- ML20101Q606 + (ML20101Q606)
- ML20101Q608 + (ML20101Q608)
- ML20101Q610 + (ML20101Q610)
- ML20101Q611 + (ML20101Q611)
- 05000499/LER-1992-005-01, :on 920608,inadvertent Start of Component Cooling Water Pump Occurred When Discharge Header Pressure Went Below Setpoint for Starting Standby Pump.Caused by Inadequate Procedure.Procedures to Be Changed + (ML20101Q612)
- ML20101Q617 + (ML20101Q617)
- ML20101Q623 + (ML20101Q623)
- ML20101Q628 + (ML20101Q628)
- ML20101Q650 + (ML20101Q650)
- ML20101Q653 + (ML20101Q653)
- TXX-4389, Forwards Status Rept Describing Unit 1 Engineering & Const Items Which Will Not Be Completed by 850117.Technical Review Team Insp Items & ASLB Issues Not Included + (ML20101Q662)
- ML20101Q664 + (ML20101Q664)
- ML20101Q666 + (ML20101Q666)
- ML20101Q672 + (ML20101Q672)
- ML20101Q673 + (ML20101Q673)
- ML20101Q681 + (ML20101Q681)
- ML20101Q687 + (ML20101Q687)
- ELV-03856, Forwards Payment of Civil Penalty in Amount of $100,000 in Response to 920612 Order Imposing Civil Monetary Penalty. Position Taken by NRC at Odds W/Widespread Practice Re Reporting Requirements + (ML20101Q690)
- ML20101Q696 + (ML20101Q696)
- ML20101Q701 + (ML20101Q701)
- 05000382/LER-1992-003, :on 920427,control Room Emergency Filtration Sys Started Automatically.Cause of Event Determined to Be Electric Spike.New resistor-capacitator Filters Have Been Installed + (ML20101Q708)
- NG-96-0299, Revised Application for Amend to License DPR-49,rewording Request for Consistency w/NUREG-1433,rev 1 + (ML20101Q713)
- ML20101Q716 + (ML20101Q716)
- ML20101Q719 + (ML20101Q719)
- ULNRC-03360, Forwards Response to NRC Bulletin 96-001, Control Rod Insertion Problems + (ML20101Q728)
- 05000244/LER-1996-004, :on 960309,decrease in Steam Generator Level Occurred.Caused by Failed Open Atmospheric Relief Valves. Booster Relay Replaced + (ML20101Q730)
- ML20101Q731 + (ML20101Q731)
- NLS8400231, Forwards Revised Pages 3-2 & 3-3 of QA Program,Per 840808 Request + (ML20101Q737)
- ML20101Q738 + (ML20101Q738)
- ML20101Q746 + (ML20101Q746)
- ML20101Q752 + (ML20101Q752)
- ML20101Q754 + (ML20101Q754)
- ML20101Q755 + (ML20101Q755)
- 05000382/LER-1992-005-08, :on 920609,control Room Emergency Filtration Sys Started Automatically.Cause of Event Was Indeterminate. Technicians Will Continue to Monitor Radiation Monitor Performance During Operations + (ML20101Q756)