This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML20099J952 + (ML20099J952)
- ML20099J959 + (ML20099J959)
- 05000416/LER-1984-045, :on 841014,adverse Weather Conditions Resulted in Voltage Transients on 500-kV Incoming Line.Caused by Precoat Bypass Valve Not Opening Immediately When Precoat Filter Valves Closed + (ML20099J964)
- ML20099J970 + (ML20099J970)
- ML20099J984 + (ML20099J984)
- ML20099J987 + (ML20099J987)
- ML20099K006 + (ML20099K006)
- ML20099K018 + (ML20099K018)
- 05000373/LER-1984-067-01, :on 841025,insp of Mechanical Fire Penetrations Identified Three Penetrations Not Sealed Properly.Caused by Const/Installation Error.Penetrations Restored to Operable Status + (ML20099K028)
- ML20099K034 + (ML20099K034)
- ML20099K038 + (ML20099K038)
- ML20099K049 + (ML20099K049)
- ML20099K053 + (ML20099K053)
- ML20099K058 + (ML20099K058)
- ML20099K085 + (ML20099K085)
- 05000373/LER-1984-069-01, :on 841023,leak Found at Fitting on Variable Leg to Instrument Rack Causing Loss of Accurate Level for Shutdown Indication for Upset & Narrow Range a & B Instruments + (ML20099K088)
- ML20099K111 + (ML20099K111)
- ML20099K116 + (ML20099K116)
- ML20099K120 + (ML20099K120)
- ML20099K134 + (ML20099K134)
- ML20099K137 + (ML20099K137)
- ML20099K139 + (ML20099K139)
- ML20099K149 + (ML20099K149)
- ML20099K155 + (ML20099K155)
- ML20099K168 + (ML20099K168)
- ML20099K172 + (ML20099K172)
- ML20099K176 + (ML20099K176)
- ML20099K177 + (ML20099K177)
- 05000445/LER-1992-020, :on 920720,output of motor-driven Auxiliary Feedwater Pump 1-02 Was Higher than Combined Flow to SG 03 & 04.Caused by Design Not Permitting Operator to Verify That Valve Closed.Procedures to Be Revised + (ML20099K189)
- 05000338/LER-1992-011-01, :on 920724,discovered That Test Procedures for ECCS Did Not Include Verifying Safety Injection Throttle Valves Tagged in Proper Position.Caused by Personnel Error. Throttle Valves Properly Tagged + (ML20099K193)
- BSEP-92-0008, Responds to Violations Noted in Insp Repts 50-317/92-19 & 50-318/92-19 on 920605-0703.Corrective Actions:Evaluation Written to Justify Temporary Repair & Operability of Svc Water/Tube Water Line & Permanent Repair Installed + (ML20099K195)
- 05000285/LER-1992-025, :on 920723,EDG DG-2 Started When Operator Inadvertently Pushed Normal Start Button Instead of Alarm Ack Button.Caused by Failure to self-check to Ensure Action correct.Self-checking Reemphasized + (ML20099K197)
- 05000318/LER-1992-004-01, :on 920718,both Independent Saltwater Loops Declared Inoperable.Caused by Blown Fuse in Control Circuit. Blown Fuse Replaced,Temporary Guidance Issued & TS Equipment Maint Policy Will Be Developed + (ML20099K200)
- ML20099K202 + (ML20099K202)
- ML20099K204 + (ML20099K204)
- ELV-03964, Responds to NRC Re Exercise Weaknesses Noted in Insp Rept 50-424/92-10 on 920518-21.Corrective Actions: Lessons Learned Issued,Discussing Timeliness of Notifications to State,Local & Federal Authorities + (ML20099K209)
- ML20099K210 + (ML20099K210)
- U-602033, Responds to Notice of Violation Documented in NRC Enforcement Action 92-110,dtd 920721.Corrective Actions: Decision Made to Leave TIP C Detector in in-vessel Storage Position to Allow for Radioactive Decay of Detector & Cable + (ML20099K211)
- 05000346/LER-1992-006, :on 920723,four Instances Identified Where Allowable Value of Trip Setpoint for TS Table 2.2-1,Item 8 Re High Flux/Number of Reactor Pumps on Exceeded.Caused by Deficient Procedures.Procedures Revised + (ML20099K213)
- ML20099K215 + (ML20099K215)
- ML20099K217 + (ML20099K217)
- ML20099K223 + (ML20099K223)
- ML20099K226 + (ML20099K226)
- ML20099K232 + (ML20099K232)
- 05000413/LER-1984-017-02, :on 841021,motor Driven Auxiliary Feedwater Pumps 1A & 1B Started Due to Trip Signal on Both Maint Feedwater Pump Turbines.Cause Unknown.Followup Rept by 841201 + (ML20099K235)
- ML20099K236 + (ML20099K236)
- ML20099K237 + (ML20099K237)
- ML20099K242 + (ML20099K242)
- 05000456/LER-1992-007-08, :on 920725,fuel Handling Bldg Ventilation Charcoal Booster Fan Automatically Started Due to Spike of Electronics Associated W/Arm OAR055J.Monitor Declared Inoperable,Tested,Observed & Declared Operable + (ML20099K243)
- ST-HL-AE-4184, Forwards Rev 15 to South Tx Project Security Personnel Training & Qualification Plan.Rev Withheld (Ref 10CFR73.21) + (ML20099K244)
- ML20099K245 + (ML20099K245)