Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML20093B867 + (ML20093B867)
- 3F1084-08, Submits Requested Addl Info Re NUREG-0737,Item II.K.2.16 Concerning Reactor Coolant Pump Seal Cooling Sys Providing Adequate Cooling Upon Loss of Offsite Power,Per NRC 840829 Safety Evaluation + (ML20093B871)
- 05000328/LER-1984-017-02, :on 840906,during Startup,Reactor Tripped While Switching Control of Steam Generator Levels from Manual to Automatic.Caused by Reduction in Reactor Power to Slow Swell of Steam Generator 3 + (ML20093B884)
- ML20093B890 + (ML20093B890)
- ML20093B900 + (ML20093B900)
- ST-HL-AE-1135, Second Interim Deficiency Rept Re Commingling of Round Rod Matls.Initially Reported on 840430.Problem Limited to Rod Matl Mfg During Period When Matl Control Identification Indicated by Color Coding & Ribbon Striping + (ML20093B910)
- ML20093B926 + (ML20093B926)
- 3F1084-02, Application for Amend to License DPR-72,requesting Authorization to Continue Using once-through Steam Generator (OTSG) Drain Lines for OTSG Blowdown for Brief Periods of Time Above High Energy Line Threshold + (ML20093B929)
- ML20093B930 + (ML20093B930)
- ML20093B934 + (ML20093B934)
- ML20093B936 + (ML20093B936)
- ML20093B940 + (ML20093B940)
- 05000311/LER-1984-021, :on 840826,trip of Steam Generator Feed Pump 21 Resulted in Steam Flow/Feed Flow Mismatch on Steam Generators & Reactor Trip.Caused by Failure of Magnetic Speed pick-up Sensor.Sensor Replaced + (ML20093B941)
- ML20093B947 + (ML20093B947)
- ML20093B952 + (ML20093B952)
- ML20093B954 + (ML20093B954)
- ML20093B958 + (ML20093B958)
- ML20093B961 + (ML20093B961)
- ML20093B962 + (ML20093B962)
- ML20093B963 + (ML20093B963)
- 05000370/LER-1984-018-01, :on 840819,during Preoperational Test,Diesel Generator 2A Unexpectedly Started Automatically.Caused by Failure to Adequately Test Automatic Fast Transfer Circuitry.Undervoltage Relays to Be Replaced + (ML20093B972)
- RBG-18942, Interim Deficiency Rept DR-188 Re Hubs on socket-weld Flanges Supplied by Guyon Alloys for Instrument Lines on Main Steam Isolation Sys.Next Rept Expected by 841121 + (ML20093B988)
- ML20093B992 + (ML20093B992)
- ML20093B995 + (ML20093B995)
- ML20093C000 + (ML20093C000)
- ML20093C001 + (ML20093C001)
- 3F0884-19, Effluent & Waste Disposal Semiannual Rept,Jan-June 1984 + (ML20093C005)
- ML20093C006 + (ML20093C006)
- ML20093C012 + (ML20093C012)
- ML20093C017 + (ML20093C017)
- 05000338/LER-1984-008-02, :on 840901,radial Flaws Discovered During Insp of HX Lap Rings.Caused by Cracking Due to Chloride Induced Stress Corrosion.Stainless Steel Installed at Point of Lap Ring + (ML20093C020)
- W3P84-2583, Interim Rept of Significant Const Deficiency 57 Re Inadequate Instrumentation & Control Installations Turnover Documentation.Rept Reopened to Resolve Issues Referenced in DG Eisenhut .Final Rept Due Approx 841005 + (ML20093C023)
- ML20093C025 + (ML20093C025)
- ML20093C026 + (ML20093C026)
- 05000331/LER-1984-033, :on 840906,electric Fire Pump Failed to Meet Flow Requirements & Plant Exceeded 7-day Limit for Pump Inoperability.Pump Impeller Adjusted to Increase Flow to Meet Requirement + (ML20093C028)
- ML20093C030 + (ML20093C030)
- 05000397/LER-1984-096, :on 840901,deluge Sys Actuated Due to Steam Leak.Fire Pump & Two pre-action Sys Tripped & Fire Alarm Received for Water Filtration Bldg.Caused by Shut Cooling Water Supply Valve to FP-P-110 Diesel Engine + (ML20093C031)
- ML20093C035 + (ML20093C035)
- ML20093C038 + (ML20093C038)
- W3P84-2582, Interim Rept of Significant Const Deficiency 101 Re Traceability of Stainless Steel Instrument Tubing.Rept Reopened to Resolve Issues Referenced in DG Eisenhut .Final Rept Due Approx 841005 + (ML20093C040)
- ML20093C043 + (ML20093C043)
- ML20093C044 + (ML20093C044)
- W3P84-2580, Interim Rept of Significant Const Deficiency 84 Re Tube Track Welding Defects.Rept Reopened to Resolve Issues Referenced in DG Eisenhut .Final Rept Due Approx 841005 + (ML20093C047)
- 05000370/LER-1984-019-01, :on 840820,while Filling & Venting Upper Head Injection Sys,Reactor Vessel Head Sight Glass Failed, Releasing RCS Water Into Containment Bldg.Caused by Design Deficiency.Sight Glass Replaced + (ML20093C049)
- ML20093C056 + (ML20093C056)
- ML20093C057 + (ML20093C057)
- ML20093C062 + (ML20093C062)
- ML20093C068 + (ML20093C068)
- 05000335/LER-1984-008-02, :on 840828,spurious Containment Isolation Signal Received.Caused by Two Shorted Instrument Bus Wires During Electrical Insp.Signal Reset + (ML20093C070)
- ML20093C073 + (ML20093C073)
- RBG-19048, Interim Deficiency Rept DR-240 Re Three Potential Problems W/Random Trip Output of Westinghouse Type SA-1 Differential Relays.Initially Reported on 840828.Interim or Final Status Rept Will Be Provided by 841027 + (ML20093C077)