- 05000251/LER-1976-004-01, /01T:on 760611,boron Concentration of Injection Tank & Two of Three Storage Tanks Below 20,000 Ppm Limit. Caused by in-leakage from Reactor Water Storage.Shutdown Initiated + (ML20090E567)
- ML20090E568 + (ML20090E568)
- ML20090E573 + (ML20090E573)
- 05000251/LER-1976-003-01, /01T:on 760517,tube Support Plate Section of Steam Generator 4C Discovered to Be Cracked.Cause Under Investigation.Manufacturer Evaluating Occurence + (ML20090E575)
- ML20090E580 + (ML20090E580)
- 05000250/LER-1976-010-03, /03L:on 761125,trip Setpoint of Steam Flow Comparator FC-3-484 Found to Be Nonconservative.Caused by Failure of Two Filter Capacitors on Printed Circuit Board. Capacitors to Be Replaced + (ML20090E582)
- ML20090E583 + (ML20090E583)
- ML20090E584 + (ML20090E584)
- ML20090E585 + (ML20090E585)
- 05000250/LER-1976-009-03, /03L:on 761015,charging Pump 3B Removed from Svc Because of Damaged Rod Bearings.Caused by Insufficient Lubrication of Bearings.Pump Casing of Pump 3B Installed on Pump 3A & Pump 3A Returned to Svc + (ML20090E587)
- 05000250/LER-1976-008-01, /01T:on 761006,boron Concentration of Injection Tank Below 20,000 Ppm Limit.Cause Undetermined.Shutdown Initiated + (ML20090E589)
- 05000251/LER-1976-007-01, /01T:on 761002,diesel Generator a Engine Cooling Water Tank Level Found Low.Caused by Sample Valve Not Being Fully Closed After 761001 Water Sample.Valve Closed & Water Added + (ML20090E592)
- 05000250/LER-1976-006-01, /01T:on 760909,closing Springs in Diesel Generator 3A Circuit Breaker Not in Charged Position.Caused by Worn Nylon Bushing Between Closing Spring Drive Motor & Linkage to Ratchet Wheel + (ML20090E595)
- 05000250/LER-1976-005-01, /01T:on 760805,Westinghouse Informed of New Development on Results of Safety Analysis.Caused by Increase of Temp of Fluid in Upper Head & Increased Rod Bow Penalty + (ML20090E597)
- ML20090E598 + (ML20090E598)
- ML20090E601 + (ML20090E601)
- L-76-300, Notifies That Westinghouse Informed Util That Recent Developments Have Affected Results of Certain Safety Analyses for Westinghouse Plants.Evaluation of Developments Continuing + (ML20090E602)
- 05000250/LER-1976-004-01, /01T:on 760611,boron Concentration of Injection Tank Below 20,000 Ppm Limit.Caused by Recirculation W/Low Concentration of Boric Acid Storage Tank B.Shutdown Initiated + (ML20090E607)
- 05000250/LER-1976-003-03, /03L:on 760519,output 1 of Pressurizer Level Comparator LC-459A Tripped at 4.685 Volts Instead of 4.680 Volts.Caused by Setpoint Drift.Trip Setpoint Reset to Conservative Value + (ML20090E608)
- 05000250/LER-1976-002-01, /01T:on 760306,closing Spring of Emergency Diesel Generator 3B Breaker Not Charged.Caused by Worn Bushing on Charging Motor Drive Pawl.Spare Breaker Installed + (ML20090E611)
- PY-CEI-NRR-1463, Rev 0 to Evaluation of Flaw Indications in Perry FW Nozzle to Safe-End Welds Extrapolated Beyond RF0-3 + (ML20090E612)
- TXX-4224, Forwards marked-up Rev to FSAR Table 17A-1,per 10CFR50.55(f)(3).Editorial Change Removes Apparent Inconsistency Involving Use of Safety Classification IE to Describe Cable Trays,Conduit & Supports for Cable Trays + (ML20090E614)
- 05000250/LER-1976-001-03, /-03L:on 760219,water Found Leaking from Charging Pump 3A.Cause of Crack in Pump Casing Not Yet Determined. Crack Weld Repaired & Pump Returned to Svc + (ML20090E615)
- ML20090E617 + (ML20090E617)
- 05000251/LER-1976-002-01, /01T:on 760214,water Level in Refueling Water Storage Tank 1% Lower than Tech Spec Requirement.Caused by Poor Calibr Ability of Wide Range Indicator Gage.Narrow Range Gage Will Be Installed as Backup + (ML20090E620)
- 05000251/LER-1976-001-03, /03L:on 760130,channel 2 Overtemp delta-T Reactor Trip Setpoint Exceeded Tech Spec Limit by One Degree.Caused by Failure of Two Filter Capacitors in Signal Summator. Capacitors Replaced + (ML20090E622)
- ML20090E627 + (ML20090E627)
- ML20090E642 + (ML20090E642)
- ML20090E651 + (ML20090E651)
- ML20090E658 + (ML20090E658)
- RBG-18171, Final Deficiency Rept DR-152 Re Wire Terminations in Gould Brown-Boveri 480-volt Standby Motor Control Ctrs (Mcc). Initially Reported on 840607.Field Insp Criteria Developed & Rework on Class IE MCCs Completed + (ML20090E659)
- ML20090E663 + (ML20090E663)
- ML20090E667 + (ML20090E667)
- ML20090E676 + (ML20090E676)
- ML20090E683 + (ML20090E683)
- ML20090E686 + (ML20090E686)
- ML20090E704 + (ML20090E704)
- ML20090E709 + (ML20090E709)
- ML20090E718 + (ML20090E718)
- ML20090E740 + (ML20090E740)
- ML20090E749 + (ML20090E749)
- 05000397/LER-1984-063, :on 840617,control Room Emergency Filtration Unit Automatically Actuated Due to Spike on Control Room Outside Air Radiation Monitor.Caused by Starting of Svc Water Pump.Alarm Reset + (ML20090E800)
- ML20090E815 + (ML20090E815)
- ML20090E831 + (ML20090E831)
- NRC-84-0102, Forwards Responses to NRC Queries Re Seismic Equipment Qualification Justifications for Interim Operation.Portions of Response Withheld (Ref 10CFR2.790) + (ML20090E834)
- 05000397/LER-1984-062, :on 840620,Tech Spec Surveillance Requirements on Rod Sequence Control Sys Not Performed in Required Time Frame.Caused by Personnel Error.Surveillance Tests Performed + (ML20090E846)
- ML20090E878 + (ML20090E878)
- ML20090E879 + (ML20090E879)
- ML20090E882 + (ML20090E882)
- ML20090E883 + (ML20090E883)
- ML20090E889 + (ML20090E889)