- ML20090D962 + (ML20090D962)
- 05000220/LER-1975-019, :on 750722,surveillance Test on Torus Vacuum Relief to Atmosphere Switches Not Completed.Caused by Failure to Note Recent Changes to Tech Specs.Revised Tech Specs Noted + (ML20090D967)
- 05000220/LER-1975-018, :on 750704,during Routine Operation,Emergency Condenser Vent Radiation Monitor Went Upscale Isolating Sys as Designed.Caused by Failure of Monitor Component Due to High Temp Environ.Monitor Replaced + (ML20090D970)
- 05000220/LER-1975-014, :on 750618,during Monthly Testing,Standby Liquid Control Sys Pump 11 Would Not Start.Caused by Unlatched Power Breaker Trigger.Breaker Reset + (ML20090D975)
- 05000220/LER-1975-016, :on 750628,during Routine Surveillance Testing, Three Reactor Water lo-lo-lo Level Sensors Found Out of Calibr.Caused by Minor Setpoint Drift.Instruments Recalibr + (ML20090D997)
- ML20090E006 + (ML20090E006)
- ML20090E007 + (ML20090E007)
- ML20090E008 + (ML20090E008)
- 05000220/LER-1975-009, :on 750414,during Function Test,Average Power Range Monitor 11 Failed to Provide High Alarm.Caused by Open Transistor in Dual Alarm Unit.Transistor Replaced + (ML20090E012)
- 05000220/LER-1975-008, :on 750414,during Normal Operation,Relay Coil in Reactor Protection Sys Relay 12K30 Shorted.Caused by Environ & High Usage.Coil Replaced + (ML20090E017)
- 05000220/LER-1975-007, :on 750412,during Quarterly Testing,Ec IV 11 (AC) Failed to Open.Caused by Loose Connection in Remote Manual Wiring Terminal Block.Connection Tightened + (ML20090E027)
- 05000220/LER-1975-006, :on 750405,during Surveillance testing,RE-18A Reactor Level lo-lo-lo Found Actuating at 131 Rather than 128.5 Inches of Water.Caused by Instrument Drift.Instrument Recalibr + (ML20090E033)
- ELV-03478, Special Rept 2-92-1:on 920205,DG 2B Declared Inoperable Due to Negative Reactive Power.Cause Undetermined.Engine Being Tested Each Wk While Monitoring Equipment Connected to Capture Any Info Useful in Investigation of Cause + (ML20090E035)
- 05000220/LER-1975-005, :on 750401,during Testing of Emergency Ventilation Sys,Reactor Protection Sys Solenoid Valve SN-831630 Failed to Open.Caused by Broken Stem & Metal Oxide Buildup.Valves Repaired + (ML20090E036)
- ML20090E037 + (ML20090E037)
- ML20090E041 + (ML20090E041)
- A10185, Responds to NRC Re Violations Noted in Insp Rept 50-336/92-03 on 920107-10.Corrective Actions:Change to TS 4.7.6.1 Will Be Proposed to Replace Wording Operating W/ Word Aligned to Ensure Proper Sys Alignment + (ML20090E044)
- ML20090E045 + (ML20090E045)
- ML20090E048 + (ML20090E048)
- PMNS20200324, Meeting with Nuclear Industry to Discuss COVID-19 Regulatory Impacts with Respect to 10 CFR Part 26 and Recently Issued Letter Regarding the Exemption Process + (ML20090E056)
- ELV-03417, Submits Addl Info Re 911118 Application for Amends to Licenses NPF-68 & NPF-81,changing TS 3.4.4 & 3.4.9.3 Re Relief Valves & Cold Overpressure Protection Sys, Respectively + (ML20090E065)
- ML20090E068 + (ML20090E068)
- ML20090E074 + (ML20090E074)
- ML20090E082 + (ML20090E082)
- ML20090E088 + (ML20090E088)
- ML20090E095 + (ML20090E095)
- ML20090E097 + (ML20090E097)
- ML20090E098 + (ML20090E098)
- ML20090E099 + (ML20090E099)
- ML20090E101 + (ML20090E101)
- ML20090E104 + (ML20090E104)
- ML20090E108 + (ML20090E108)
- ML20090E113 + (ML20090E113)
- 05000220/LER-1975-003, :on 750212,during Plant Startup,Waste Evaporator Concentrator Failed,Resulting in Leakage.Caused by Sulfuric Acid Contamination + (ML20090E116)
- ML20090E124 + (ML20090E124)
- ML20090E125 + (ML20090E125)
- ML20090E126 + (ML20090E126)
- 05000220/LER-1975-004, :on 750212,during Plant Startup,Feedwater Pump 12 Failed to Start.Caused by Broken Linkage on Suction Pressure Switch Due to Vibration.Switch Linkage Replaced + (ML20090E128)
- ML20090E137 + (ML20090E137)
- 05000220/LER-1975-001, :on 750109,level Control Valve to Emergency Condensers Failed,Resulting in High Water Level Alarm.Caused by Inability to Close Valve.Level Maintained W/Manual Valve. Spare Controller Installed + (ML20090E139)
- ML20090E140 + (ML20090E140)
- ML20090E149 + (ML20090E149)
- ML20090E155 + (ML20090E155)
- ML20090E157 + (ML20090E157)
- ML20090E158 + (ML20090E158)
- ML20090E159 + (ML20090E159)
- ML20090E161 + (ML20090E161)
- ML20090E163 + (ML20090E163)
- ML20090E164 + (ML20090E164)
- ML20090E165 + (ML20090E165)
- ML20090E166 + (ML20090E166)