Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML20085L365 + (ML20085L365)
- ML20085L367 + (ML20085L367)
- ML20085L373 + (ML20085L373)
- ML20085L377 + (ML20085L377)
- ML20085L380 + (ML20085L380)
- ML20085L383 + (ML20085L383)
- ML20085L392 + (ML20085L392)
- ML20085L409 + (ML20085L409)
- ML20085L411 + (ML20085L411)
- ML20085L414 + (ML20085L414)
- 05000267/LER-1977-004, :on 770118,during Routine Surveillance of Class 1 Hydraulic Shock Suppressors,Four Suppressors Were Inoperable.Three Inoperable Due to Empty Oil Reservoirs & One Clevis Pin Needed Replacing + (ML20085L416)
- 05000267/LER-1977-003, :on 770115,during Rise to Power Testing,Loop 1 Hydraulic Oil Reservoir Level Switch Failure Caused Two Hydraulic Oil Pumps to Become Inoperable.Level Switch Mechanism Cleaned & Switch Adjusted + (ML20085L417)
- 05000267/LER-1977-002, :on 761227,during Test of Electrohydraulic Control Hydraulic Pumps for Main Turbine,Turbine Tripped.Trip Caused Loss of Power to Helium Circulator Bearing Water Pumps. Caused by Pump Control Malfunction + (ML20085L423)
- 05000267/LER-1977-001, :on 770104,during Rise to full-power Testing,Maint Personnel Observed No Visible Oil Level in BFS-297 Snubber on Class 1 Piping Sys.Caused by Normal Wear.Pin Gland Tightened & Oil Reservoir Refilled + (ML20085L427)
- A14049, Investigation Into Causes & Consequences of Malfunction of Static Shutdown Seal S/N 3 in Fort St Vrain Circulator C2102 from D Penetration + (ML20085L433)
- A13823, Fort St Vrain Dew Point Moisture Monitor Sys Post-Mod Test Results (RT-355C) + (ML20085L440)
- ML20085L441 + (ML20085L441)
- RBG-35-850, Lists Milestones Scheduled to Implement Emergency Response Data Sys at Facility & Forwards Description of Elements & Details of Implementation Plan.Sys Will Be Fully Tested & Implemented by Feb 1993 + (ML20085L442)
- A13175, Investigation Into Cause & Consequence of Fort St Vrain Pelton Wheel Incipient Fractures + (ML20085L444)
- A12714, Public Svc Corp Prenuclear Pelton Wheel Cavitation Rept + (ML20085L450)
- ML20085L465 + (ML20085L465)
- ML20085L466 + (ML20085L466)
- ML20085L468 + (ML20085L468)
- ML20085L469 + (ML20085L469)
- ML20085L473 + (ML20085L473)
- ML20085L476 + (ML20085L476)
- ML20085L479 + (ML20085L479)
- 3F1091-14, Forwards Response to Generic Ltr 91-06, Resolution of Generic Issue A-30, Adequacy of Safety-Related DC Power Supplies. Generic Ltr Should Have Received Current Review by CRGR + (ML20085L501)
- ML20085L502 + (ML20085L502)
- BECO-91-136, Application for Amend to License DPR-35,changing Tech Spec 3.5.D.2, RCIC Sys,Under Exigent Circumstances to Provide Limited Extension of 7-day LCO + (ML20085L511)
- JPN-95-030, Forwards ISI Summary Rept..., Providing Summary of ISI Exams Conducted During 1995 Refuel Outage (Reload 11/Cycle 12).Info Re Operating Status of FW Nozzle Leakage Monitoring Sys & Measured Leakage for FW Nozzles Also Encl + (ML20085L513)
- ML20085L518 + (ML20085L518)
- ML20085L519 + (ML20085L519)
- ML20085L520 + (ML20085L520)
- ML20085L523 + (ML20085L523)
- ML20085L525 + (ML20085L525)
- 3F0695-03, Forwards Response to GL-95-03, Circumferential Cracking of SG Tubes, Per 10CFR50.54(f) + (ML20085L526)
- BSEP-95-0304, Forwards Response to Violations Noted in Insp Repts 50-324/95-10 & 50-325/95-10.Corrective Actions:Requires That Licensee Maintain Control of Quality by Contractors + (ML20085L527)
- 3F1091-17, Suppls 910613 & 0703 Responses to NRC Supplemental Safety Evaluation Re Station Blackout Rule Implementation.Inverter Test Rept from Solidstate Controls,Inc Documents Successful Completion of Two 8 H Tests + (ML20085L528)
- 3F1091-12, Suppls 891103 Response to Generic Ltr 88-20 Re Individual Plant Exam Schedule & Status.Basic Accident Progression Analysis & Quantification of Source Terms for Level 2 Portion of Individual Plant Exam Completed + (ML20085L530)
- ML20085L532 + (ML20085L532)
- ML20085L533 + (ML20085L533)
- NLS9100666, Forwards Response to Generic Ltr 91-06, Resolution of Generic Issue A-30, Adequacy of Safety-Related DC Power Supplies + (ML20085L535)
- ML20085L537 + (ML20085L537)
- ML20085L541 + (ML20085L541)
- ML20085L548 + (ML20085L548)
- ST-HL-AE-3901, Forwards Response to Generic Ltr 91-06, Resolution of Generic Issue A-30, Adequacy of Safety-Related DC Power Supplies. Facilities Do Not Have Battery Charger Failure Alarms + (ML20085L549)
- 05000263/LER-1995-005-01, :on 950518,two Main RB Supply Fans Tripped. Caused by Electrical Disturbance on 345 Kv Power Lines Connected to Plant Substation.Ventilation Configuration Changed + (ML20085L550)
- ML20085L563 + (ML20085L563)
- ML20085L566 + (ML20085L566)
- ML20085L572 + (ML20085L572)