- 05000416/LER-1983-077-03, /03L-0:on 830622,while Performing Control Room Standby Fresh Air Unit a Monthly Surveillance,Unit Heater Failed to Operate.Caused by Malfunctioning Control Relay. Relay Replaced + (ML20085D821)
- ML20085D824 + (ML20085D824)
- ML20085D825 + (ML20085D825)
- ML20085D829 + (ML20085D829)
- BSEP-83-2343, RO 2-SR-83-18:on 830614,five Barrier Limiting Conditions for Operations Generated for Two Fire Doors in Diesel Generator Bldg.Two Fire Doors Declared Inoperable Due to Broken Counterbalance Spring & Misalignment + (ML20085D831)
- ML20085D842 + (ML20085D842)
- ML20085D848 + (ML20085D848)
- ML20085D852 + (ML20085D852)
- ML20085D853 + (ML20085D853)
- RC-95-0138, Forwards Amend 95-02 to FSAR for VC Summer Nuclear Station. FSAR Amend Updated as of 950327 & Constitutes Second Update to FSAR for 1995,including Required Info in Accordance W/ 10CFR50.71(e) + (ML20085D855)
- ML20085D856 + (ML20085D856)
- ML20085D861 + (ML20085D861)
- ML20085D866 + (ML20085D866)
- 05000277/LER-1991-021, :on 910624,pressure Transmitters Determined to Be non-seismically Supported.Caused by Improper Rack Installation.On 910909,incorrect Root Valve Closed Due to Labeling Error.Labels Corrected + (ML20085D868)
- ML20085D869 + (ML20085D869)
- ML20085D871 + (ML20085D871)
- ML20085D880 + (ML20085D880)
- ML20085D883 + (ML20085D883)
- ML20085D885 + (ML20085D885)
- ML20085D888 + (ML20085D888)
- ML20085D892 + (ML20085D892)
- ML20085D897 + (ML20085D897)
- BECO-91-129, Requests Extension of Three Months to Implement Program Changes Required for Relief Requests RP-1 & RP-5,per NRC ,Issuing SER for Inservice Test Program + (ML20085D898)
- 05000348/LER-1983-036-03, /03L-0:on 830629,steam Generator 1B wide-range Level Indicator on Remote Shutdown Panel Declared Inoperable Due to Erratic Readings.Caused by Failure of Printed Circuit Card.Card Replaced + (ML20085D901)
- 05000338/LER-1983-045-03, /03L-0:on 830628,containment Average Temp Exceeded 105 F Twice for Less than 4 H.First Temp Spike Caused by Mechanical Chiller Tripping on High Lube Oil Temp & Second Caused by Loss of Bearing Cooling to Chiller + (ML20085D903)
- ML20085D904 + (ML20085D904)
- 05000280/LER-1982-094-03, TV-SS-106A & B (Reactor Coolant Hot Leg Sample Trip Valves) Failed to Fully Close After RCS Sample.Cause Undetermined.Valves Tested Satisfactorily & Returned to Svc + (ML20085D905)
- 05000395/LER-1983-068-03, /03L-0:on 830620,snubber FWH-1109 (Feedwater Sys) Declared Inoperable Due to Bearing Offset.Caused by Maint Activity in Immediate Area.Bearing Centered,Restaked,Tested & Declared Operable on 830620 + (ML20085D907)
- ML20085D909 + (ML20085D909)
- ML20085D911 + (ML20085D911)
- ML20085D912 + (ML20085D912)
- ML20085D913 + (ML20085D913)
- 05000261/LER-1983-015-01, /01T-0:on 830622,w/unit at 80% Power,Increase in Total Primary Sys Leakage to 1.19 Gpm Identified.Caused by Defective Sensing Line Fitting.Abnormal Degradation of RCPB Declared on 830705.Fitting Replaced + (ML20085D914)
- ML20085D916 + (ML20085D916)
- 05000302/LER-1983-023, Updated LER 83-023/01T-1:on 830613,fire Damper Discovered Missing.Approx 55 Addl Dampers & Chase Connecting Control Complex 108 & 165 Ft Elevations Degraded Due to Incorrect Fire Rating.Caused by Personnel Error + (ML20085D918)
- ML20085D919 + (ML20085D919)
- 05000395/LER-1983-069-03, /03L-0:on 830620,snubber FWH-0265 Declared Inoperable Due to Misalignment & Bent Paddle Plate.Caused by Transient Loading During Startup.Snubber Replaced W/Unit Modified to Suit Dimensional Requirements + (ML20085D921)
- 05000339/LER-1983-051-03, /03L-0:on 830627 & 0702,RCS Subcoolant Margin Monitor a Failed to Operate Correctly.Cause on 830627 Due to Failed Low Level Data Board & on 830702 Due to Failed Computation Board.Monitor Will Be Relocated + (ML20085D922)
- ML20085D923 + (ML20085D923)
- 05000338/LER-1981-062-03, Util Notified That 15 Block Walls in Fuel Bldg Did Not Meet Design Requirements of IE Bulletin 80-11.Caused by Refinement in Masonry Wall Design.Block Walls to Be Replaced + (ML20085D925)
- ML20085D926 + (ML20085D926)