- ML20083R747 + (ML20083R747)
- ML20083R749 + (ML20083R749)
- 05000244/LER-1984-003, :on 840307,valves MOV-851A & B Mistakenly Opened Prior to Shutting Valve MOV-850A,resulting in Draining Water from RCS Loop to Sump B.Caused by Human Error.Minor Rev to Procedure O-2.2 Initiated + (ML20083R750)
- ML20083R753 + (ML20083R753)
- ML20083R761 + (ML20083R761)
- ML20083R764 + (ML20083R764)
- ML20083R768 + (ML20083R768)
- ML20083R771 + (ML20083R771)
- 05000364/LER-1984-002, :on 840123,hourly Firewatch Patrol in Train B Auxiliary Bldg Battery Charger Room Not Performed During 1300-1400 & 1400-1500 H.Caused by Personnel Error. Individual Counseled + (ML20083R772)
- ML20083R774 + (ML20083R774)
- 05000387/LER-1983-140-03, Valve Controlling Cooling Water Flow to HPCI Lube Oil Cooler & Barometric Condenser Would Not Cycle Electrically.Caused by Torque Switch Not Actuating Due to Conditions in Spring Pack + (ML20083R778)
- ML20083R785 + (ML20083R785)
- ML20083R786 + (ML20083R786)
- ML20083R792 + (ML20083R792)
- ML20083R796 + (ML20083R796)
- ML20083R800 + (ML20083R800)
- ML20083R803 + (ML20083R803)
- ML20083R807 + (ML20083R807)
- ML20083R808 + (ML20083R808)
- 05000237/LER-1977-001-01, /01T-0 on 770117,notification Received from GE That MAPLHGR Absolute Limits No Longer Considered Sufficiently Conservative.Caused by Error in MAPLHGR Calculations.Tech Spec Rev Request Initiated + (ML20083R821)
- ML20083R826 + (ML20083R826)
- 05000237/LER-1976-074-01, /01T-0:on 761228 During Start Up Operations, Control Rod J-2 Was Withdrawn One Notch.Caused by Combination of Existing Conditions Resulting in High Reactivity Worth.Normal Scram Recovery Occurred + (ML20083R833)
- 05000237/LER-1976-040-03, /03L-0:on 760607,while Investigating Problem W/ Steam Jet Air Ejector 2A Flow Dropping to Zero,Thud Heard in Area.Cause Unknown.Investigation Initiated Addressing Origin & Prevention of Offgas Explosions + (ML20083R836)
- RBG-41486, Discusses LAR 94-04,extending Action Times of Leakage Control Sys + (ML20083R845)
- 05000237/LER-1976-073-03, /03L-0:on 761117 During Start Up Operations, Nitrogen Storage Tank Level Dropped Below Tech Spec Limit. Addl Nitrogen Delivered to Restore Storage Tank Level + (ML20083R847)
- ML20083R860 + (ML20083R860)
- 05000237/LER-1976-039-03, /03L-0:on 760531,LPCI & Core Spray Monthly Operability Checks Not Performed as Required by Tech Specs. Caused by Personnel Error.Lpci Subsys Operated on Several Occasion + (ML20083R863)
- 05000244/LER-1976-011-01, /01T:on 760308,during Flow Test of Control Room Ventilation Sys,Zero Flow Indicated for Cleanup Path Designed for 25% Total Sys Flow.Caused by Drive Piston Being Improperly Mounted During const.W/7760319 Ltr + (ML20083R872)
- ML20083R873 + (ML20083R873)
- ML20083R879 + (ML20083R879)
- B11099, Forwards Revised Summary of NRC 840214 Meeting W/Util & S&W Re Status & Proposed Resolution of Draft SER Open Items on Geotechnical Issues,Per NRC Request for Addl Info.W/Seven Oversize Figures.Aperture Cards in PDR + (ML20083R882)
- ML20083R888 + (ML20083R888)
- SNRC-1024, Submits Results of Actions Taken to Comply W/Requirements of IE Bulletin 83-08 Re Electrical Circuit Breakers W/Undervoltage Trip Feature in Use in safety-related Applications Other than Reactor Trip Sys + (ML20083R891)
- 2CAN948404, Forwards Comprehensive Rept & Schedules for Proposed Instrument Upgrades,Per Suppl 1 to NUREG-0737 & Reg Guide 1.97.Progress of Implementation & Upgrades Will Be Reported Biannually + (ML20083R892)
- ML20083R896 + (ML20083R896)
- 05000237/LER-1976-038-01, /01T-0:on 760526,sample Valve Reopened Per Procedure When Valve Discovered Closed for 40-h Period During Routine Counting of Chimney Sample Cartridges.Caused by Personnel Error + (ML20083R906)
- ML20083R910 + (ML20083R910)
- ML20083R915 + (ML20083R915)
- 05000244/LER-1976-008-01, /01T:on 760227,during Planned Current Insp of Steam Generator tubes,39 Tubes in Steam Generator Inlet a & 2 Tubes in Steam Generator Inlet B Showed Defects Above Wastage Limit.Caused by Corrosion + (ML20083R916)
- 05000387/LER-1984-020, :on 840321,shutdown Cooling Suction Inboard & Outboard Isolation Valves Closed Due to Spurious Actuation of RHR Sys Differential Pressure Switches.Cause Not Stated. Shutdown Cooling Operation Will Be Observed + (ML20083R917)
- 05000237/LER-1976-072-03, /03L-0:on 761228,during Start Up Operations,Crd J-11 Found to Uncouple & Overtravel When Withdrawn to Position H8.Caused by Loosened Inner Filter.Crd J-11 to Be Disassembled & Inspected + (ML20084A010)
- ML20084A012 + (ML20084A012)
- ML20084A013 + (ML20084A013)
- ML20084A014 + (ML20084A014)
- ML20084A018 + (ML20084A018)
- 05000237/LER-1976-037-03, Reactor Protection Sys Bypass Pressure Switch Ps 2-263-51A Found to Actuate Above Tech Spec Limit.Caused by Instrument Setpoint Drift.Switch Adjusted.Monthly Insp Will Be Conducted + (ML20084A024)
- ML20084A026 + (ML20084A026)
- ML20084A027 + (ML20084A027)
- ML20084A028 + (ML20084A028)
- ML20084A034 + (ML20084A034)
- 05000244/LER-1976-007, Revised LER 76-07/30:on 760207,relays for Train a Containment Isolation & Ventilation Isolation Failed to Latch.Caused by MG-6 Relays Having Improper Latch Screw Factory Adjustment + (ML20084A035)