- ML20083M260 + (ML20083M260)
- 05000395/LER-1982-062, Forwards LER 82-062/03L-0.Detailed Event Analysis Encl + (ML20083M264)
- 05000247/LER-1982-049, Forwards LER 82-049/99X-0 + (ML20083M269)
- ML20083M270 + (ML20083M270)
- ML20083M273 + (ML20083M273)
- ML20083M278 + (ML20083M278)
- 05000250/LER-1982-019, Forwards LER 82-019/03L-0 + (ML20083M280)
- ML20083M281 + (ML20083M281)
- 05000395/LER-1982-062-03, /03L-0:on 821220,seismic Switch YM-1782 Found to Have out-of-tolerance Trip Point on Transverse Sensor. Caused by Setpoint Drift on Horizontal Transverse Sensor. Switch Calibr & Returned to Svc + (ML20083M284)
- ML20083M286 + (ML20083M286)
- ML20083M287 + (ML20083M287)
- ML20083M288 + (ML20083M288)
- 05000373/LER-1982-175, Forwards LER 82-175/03L-0 + (ML20083M289)
- ML20083M293 + (ML20083M293)
- ML20083M299 + (ML20083M299)
- ML20083M303 + (ML20083M303)
- ML20083M304 + (ML20083M304)
- 05000373/LER-1982-175-03, /03L-0:on 821224,div 2 Position Indicator of Containment Vacuum Breaker 1PCOO1B Would Not Indicate Closed.Cause Undetermined.Work Request Written,Insp Performed & Vacuum Breaker Repeatedly Cycled + (ML20083M307)
- ML20083M310 + (ML20083M310)
- 05000250/LER-1982-019-03, /03L-0:on 821223,while Performing Full Length Rod Control Cluster Periodic Exercise,Rod Control Cluster J3 of Shutdown Bank a Failed to Show Proper Movement.Cause Unknown.Cluster Performed Normally During Rod Exercise + (ML20083M311)
- ML20083M314 + (ML20083M314)
- 05000265/LER-1983-001, Forwards LER 83-001/03L-0 + (ML20083M315)
- ML20083M317 + (ML20083M317)
- 05000247/LER-1982-049-99, /99X-0:on 821218,during Cycle 5/6 Refueling Outage,Ability of Central Control Room to Be Totally Isolated During Accidents Questioned Because Potential Air Leak Paths Identified.All Potential Paths Sealed + (ML20083M325)
- ML20083M326 + (ML20083M326)
- 05000395/LER-1982-063, Forwards LER 82-063/03L-0.Detailed Event Analysis Encl + (ML20083M333)
- ML20083M337 + (ML20083M337)
- 05000265/LER-1983-001-03, /03L-0:on 830102,offgas Radiation Monitor 1 Failed.Caused by Faulty Resistor in Power Supply to Monitor. Resistor Replaced + (ML20083M339)
- 05000296/LER-1983-005, Forwards LER 83-005/03L-0 + (ML20083M343)
- ML20083M344 + (ML20083M344)
- 05000387/LER-1984-017, :on 840310,spray Pond Riser Networks A-1 & B-2 Found Frozen.Cause Not Stated.Networks Thawed by Ambient Temp & Guidelines Developed for Spray Pond Operation to Avoid Riser Freezing + (ML20083M346)
- ML20083M348 + (ML20083M348)
- 05000219/LER-1982-060, Forwards LER 82-060/03L-0.Detailed Event Analysis Encl + (ML20083M349)
- ML20083M350 + (ML20083M350)
- ML20083M352 + (ML20083M352)
- 05000237/LER-1983-001, Forwards LER 83-001/03L-0 + (ML20083M353)
- ML20083M356 + (ML20083M356)
- 05000361/LER-1982-150-01, /01T-0:on 821229,Kerotest Valve Incorrectly Installed Restricting Flow Through Liquid Radwaste Monitor RT-7813.Caused by Improper Installation.Valve Realigned & Liquid Effluent Releases Sampled + (ML20083M357)
- ML20083M358 + (ML20083M358)
- 05000387/LER-1983-001, Forwards LER 83-001/01T-0 + (ML20083M362)
- 05000237/LER-1983-001-03, /03L-0:on 830101,cracked Weld Discovered at Feedwater Heater 2D2 Emergency Spill to Normal Drain Line Connector.Caused by Excessive Movement of Drain Line.Weld Will Be Repaired During Upcoming Refueling Outage + (ML20083M365)
- ML20083M367 + (ML20083M367)
- ML20083M368 + (ML20083M368)
- 05000219/LER-1982-060-03, /03L-0:on 821210,reactor Mode Switch Repositioned from Shutdown to Refuel While Intermediate Range Monitor Channels 16 & 17 Out of Svc.Caused by Personnel Error.Strict Compliance W/Tech Specs Emphasized + (ML20083M371)
- 05000395/LER-1982-066, Forwards LER 82-066/03L-0.Detailed Event Analysis Encl + (ML20083M377)
- 05000387/LER-1983-001-01, /01T-0:on 830105,main Condenser Offgas Monitor Train Declared Inoperable Precipitating Entry Into Action Statement Requiring Grab Sample Be Taken Every 4 H.Sample Not Taken Due to Technician Error + (ML20083M382)
- 05000361/LER-1982-167, Forwards LER 82-167/03L-0.Detailed Event Analysis Submitted + (ML20083M388)
- 05000387/LER-1982-078, Forwards LER 82-078/03L-0 + (ML20083M392)
- 05000395/LER-1982-063-03, /03L-0:on 821220,isotopic Iodine Analysis Not Performed within 6 H After Plant Went from 5% to 21% Thermal Power within 1 H.Caused by Failure to Notify Chemistry Dept to Perform Analysis.Procedure Developed + (ML20083M397)
- 05000318/LER-1982-008, Forwards Updated LER 82-008/03X-1 + (ML20083M402)