- RBG-16-639, Interim Deficiency Rept DR-140 Re Engine Mounted Fuel Oil Line in Standby Diesel Generator.Investigation Incomplete. Next Rept Will Be Submitted by 840402 + (ML20083H630)
- ML20083H631 + (ML20083H631)
- 05000327/LER-1983-186-03, /03L-0:on 831209,diesel Generator 1A-A Tripped on High Crankcase Pressure.Caused by Improperly Torqued Wrist Pin Bolts on Cylinder 8.Diesel Repaired.Affected Parts Sent to General Motors Electromotive Div for Insp + (ML20083H632)
- 05000387/LER-1983-161-01, /01T-0:on 831209,during Refueling,Rcs Temp Allowed to Exceed 140 F.Shutdown Cooling Sys Operable & in Svc. Caused by Flawed Procedures.Reactor Coolant Temp Not Recorded While in Operational Condition 5 + (ML20083H633)
- ML20083H636 + (ML20083H636)
- ML20083H637 + (ML20083H637)
- ML20083H638 + (ML20083H638)
- ML20083H639 + (ML20083H639)
- ML20083H640 + (ML20083H640)
- ML20083H641 + (ML20083H641)
- ML20083H642 + (ML20083H642)
- L-83-599, Responds to Requesting Review of Info Summary of Radioactive Effluents During 1981.Info Verified to Be Correct + (ML20083H648)
- 05000311/LER-1983-065-03, /03L-0:on 831207,diesel Generator 2B Voltage Regulator Failed,Causing Generator Breaker to Trip on Overcurrent.Caused by Grounded Voltage Regulator Control Power Transformer.Transformer Replaced + (ML20083H650)
- ML20083H651 + (ML20083H651)
- RBG-16-640, Interim Deficiency Rept DR-112 Re 1E Battery Chargers Supplied by Power Conversion Products,Inc.Investigation Incomplete.Next Rept Will Be Provided by 840316 + (ML20083H652)
- ML20083H655 + (ML20083H655)
- AECM-83-0777, Responds to NRC Re Violations Noted in IE Insp Rept 50-416/83-46.Corrective Actions:Surveillance Procedure 06-ME-1M61-V-0001 Revised & Reissued as Rev 20.TCN 7 Requiring Valve Alignment Sketch Incorporated + (ML20083H657)
- 05000373/LER-1983-148-03, /03L-0:on 831118,bus 142Y Deenergized & Switchgear 136X Equipment Failed to Loadshed.Caused by Main Sensing Contact Welding Closed.Contact Separated & Burnished + (ML20083H661)
- ML20083H662 + (ML20083H662)
- ML20083H663 + (ML20083H663)
- ML20083H664 + (ML20083H664)
- ML20083H669 + (ML20083H669)
- ML20083H673 + (ML20083H673)
- ML20083H676 + (ML20083H676)
- 05000267/LER-1983-052-03, /03L-0:on 831208,prestressed Concrete Reactor Vessel Cooling Water Outlet Temp Exceeded 120 F Limit.Caused by Absence of Svc Water Preventing Necessary Heat Exchange. Flow Returned to Sys 46 HX + (ML20083H677)
- ML20083H690 + (ML20083H690)
- RBG-16-678, Forwards Changes to FSAR Section 2.4 in Response to Items Identified by Environ & Hydrological Engineering Branch in Draft SER Re Local Flooding.Changes Will Be Incorporated Into Next FSAR Amend + (ML20083H698)
- ML20083H700 + (ML20083H700)
- RBG-16-711, Interim Deficiency Rept DR-137 Re Preheat Requirements for Pipe Support Welds.Investigation Continuing.Next Rept Will Be Provided by 840410 + (ML20083H701)
- ML20083H703 + (ML20083H703)
- BECO-83-301, Application for Proposed Tech Spec Change 83-15 to License DPR-35,correcting Error in GE Oct 1983 Reload Licensing Submittal for Restart from Refueling Outage 6 + (ML20083H705)
- ML20083H711 + (ML20083H711)
- 05000311/LER-1983-061-03, /03L-0:on 831207,during Maint Shutdown,Safeguards Equipment Control Channel 2A Inadvertently Actuated While Testing,Causing Vital Bus 2A to Be Deenergized.Caused by Reversing Polarity of Leads + (ML20083H712)
- ML20083H713 + (ML20083H713)
- ML20083H717 + (ML20083H717)
- W3P83-3555, Forwards Public Version of Revised Emergency Plan Implementing Procedures,Including Procedures EP-2-020 Re Contaminated Injured/Ill personnel,EP-2-032 Re Monitoring & Decontamination & EP-2-081 Re Search & Rescue + (ML20083H720)
- 05000305/LER-1983-034-03, /03L-0:on 831206,containment Fan Coil Unit 1D Removed from Svc to Repair Svc Water Leaks.Caused by Sand & Water Erosion of Return Bends in Svc Water Cooling Coils. Affected Bends Replaced + (ML20083H723)
- ML20083H725 + (ML20083H725)
- ML20083H726 + (ML20083H726)
- 3F1283-24, Forwards Supplemental Response to Re Violations Noted in IE Insp Rept 50-302/83-14.Corrective Actions:All Other Applicable Welds Reviewed to Verify Proper Weld Coverage.No Discrepancies Revealed + (ML20083H729)
- ML20083H731 + (ML20083H731)
- 05000272/LER-1983-061-03, /03L-0:on 831209,reactor Trip Sys & ESF Actuation Sys Instrumentation Surveillance Testing Not Completed within 1 H Limit Required by Tech Specs.Caused by Typographical Error in Procedure + (ML20083H733)
- ML20083H738 + (ML20083H738)
- 05000316/LER-1982-016, Forwards Updated LER 82-016/03X-1 & LERs 83-121/03L-0 & 83-122/03L-0 + (ML20083H739)
- ML20083H741 + (ML20083H741)
- ML20083H746 + (ML20083H746)
- 05000311/LER-1983-064-03, /03L-0:on 831202,during Surveillance Test on Low Pressure Carbon Dioxide Fire Suppression Sys,Pilot Valve 2FP377 Did Not Completely Seat.Caused by Frost on Valve Seat.Valve Seated Properly + (ML20083H749)
- 05000316/LER-1982-016-03, Pinhole Leak Discovered on Suction Strainer for West Containment Spray (CTS) Pump. Caused by Fatigue.Pinhole Removed by Grinding & Rewelding + (ML20083H754)
- 0CAN078309, Responds to NRC Re Violations Noted in IE Insp Repts 50-313/83-10 & 50-368/83-10.Corrective Actions: Procedure 1622.017, Operation of Control Point, Will Be Issued on 830930 + (ML20083H757)
- ML20083H762 + (ML20083H762)
- 05000373/LER-1983-151-03, /03L-0:on 831128,Functional Test LIS-NR-02, Required for Operating Conditions 2-5 Due 831125 Not Performed Until 831128.Caused by Personnel Error.Stronger Emphasis on Surveillance Program Implemented + (ML20083H764)