- ML20081K119 + (ML20081K119)
- 05000328/LER-1983-140-03, /03L-L:on 831003,w/unit in Refueling Operations, Discovered Containment Sump Level Channels LT-63-176,-177 & -178 Out of Calibr.Caused by Air Leakage Around O-ring Seal on Oil Filled Ref Leg of Sense Lines + (ML20081K121)
- ML20081K122 + (ML20081K122)
- 05000321/LER-1983-098-03, /03L-0:on 831007,during Performance of RHR Svc Water Operability & Rated Flow Procedure,Pump E11-C001A Failed to Maintain Required Pressure While Maintaining Rated Flow.Caused by Improper Valve Stroke + (ML20081K123)
- ML20081K125 + (ML20081K125)
- ML20081K128 + (ML20081K128)
- 05000416/LER-1983-151-03, /03L-0:on 830928,RCIC Sys Declared Inoperable Due to Surveillance Requirement 4.7.3.C.2 Not Completed within 12 H of Reactor Steam Pressure Reaching 150 Psig.Caused by Failed Ramp Module.Module Replaced + (ML20081K129)
- 05000272/LER-1983-039-03, /03L-0:on 830904,P-250 Computer CRT Did Not Display Updated Info,Rendering RCS Subcooling Monitor Inoperable.Caused by Computer Being Electronically Locked Up.Computer Cleared & Rebootstrapped + (ML20081K138)
- ML20081K147 + (ML20081K147)
- ML20081K155 + (ML20081K155)
- ML20081K157 + (ML20081K157)
- ML20081K158 + (ML20081K158)
- 05000374/LER-1995-004-02, :on 950228,determined That on Three Separate Occasions Between 950220-24 That Hourly Fire Watches Not Performed.Caused by Mgt Deficiency.Immediate Investigation Conducted + (ML20081K159)
- ML20081K161 + (ML20081K161)
- ML20081K165 + (ML20081K165)
- ML20081K170 + (ML20081K170)
- ML20081K178 + (ML20081K178)
- ML20081K182 + (ML20081K182)
- ML20081K183 + (ML20081K183)
- 05000328/LER-1983-127-03, /03L-0:on 831004,discovered Pressurizer Safety Valves 2-RV-68-563 - 565 Not Tested within Setpoint Lift Setting Limits.Caused by Valve Spring Relaxation.Two Valves Replaced & One Repaired + (ML20081K187)
- 05000327/LER-1983-142-03, /03L-0:on 831007,w/unit in Mode 1,plant Procedure Listing safety-related Snubbers SI-162.1 Discovered Not in Agreement in Number W/Table 4.7.9a of Limiting Condition for Operation 3.7.9.Caused by Misinterpretation + (ML20081K197)
- 05000364/LER-1983-044-03, /03L-0:on 831005,train a Penetration Room Filtration Sys Declared Inoperable Due to Unacceptable Charcoal Adsorber.Caused by Use of Train for Removal of RHR Pump Room Smoke.Adsorber Replaced + (ML20081K198)
- ML20081K208 + (ML20081K208)
- ML20081K218 + (ML20081K218)
- 05000338/LER-1983-071-03, /03L-0:on 831009,w/unit in Mode 5,one Train of RCS Low Temp Overpressurization Protection Sys Taken Out of Svc. Caused by Vent Valve Malfunction in Liquid Nitrogen Plant, Making Train Unavailable for Nitrogen Makeup + (ML20081K227)
- 0CAN039510, Forwards Revised List for Plant Distribution of NRC Correspondence + (ML20081K230)
- ML20081K234 + (ML20081K234)
- ML20081K236 + (ML20081K236)
- 05000259/LER-1983-058-03, /03L-0:on 831007,during Emergency Cooling Water Pipe Replacement,Check Valve 1-67-660,Daniels Series 1600, Discovered Installed Backwards.Sys Modified W/New Piping & Valves + (ML20081K257)
- 0CAN039502, Provides Certificates of Insurance Issued to Util,As Evidence of Primary & Excess Onsite Property Damage Insurance Coverage for Plant + (ML20081K259)
- 05000328/LER-1983-141-03, /03L-0:on 831004,during Shutdown for Refueling, Steam Header Pressure Channel 2-PS-1-9 Discovered Out of Calibr.Caused by Instrument Drift.Loop Recalibr + (ML20081K273)
- 05000364/LER-1983-046-03, /03L-0:on 831003,04,05,06 & 11,hydraulic Snubbers & Two Mechanical Snubbers Declared Inoperable After Failing Hydraulic Snubber Visual Test & Snubber Functional Test. Probably Caused by Excessive Heat & Vibration + (ML20081K275)
- ML20081K283 + (ML20081K283)
- 05000328/LER-1983-132-03, /03L-0:on 831007,w/unit in Mode 3,steam Generator Blowdown Liquid Effluent Radiation Monitor Declared Inoperable.Caused by Failure to Maintain Adequate Sample Flow.Change to HX Expected + (ML20081K285)
- ML20081K295 + (ML20081K295)
- LD-95-013, Transmits Supplementary Revs for Incorporation Into DCD & Affidavit.Changes Resolve Inconsistencies Identified by NRC & by ABB-CE + (ML20081K297)
- ML20081K299 + (ML20081K299)
- ML20081K310 + (ML20081K310)
- PY-CEI-NRR-1890, Application for Amend to License NPF-58 Re one-time Extension of Performance Intervals for Certain TS Surveillance Requirements + (ML20081K312)
- ML20081K319 + (ML20081K319)
- ML20081K321 + (ML20081K321)
- 05000260/LER-1983-062-03, /03L-0:on 831004,while Performing Surveillance Instruction 4.9.A.1(a),second Starter on Diesel Generator C Engaged W/Diesel While Operating at 900 Rpm.Caused by Air Leak in Solenoid Valve.New Valve Installed + (ML20081K331)
- 05000369/LER-1983-092-03, /03L-0:on 830926,QA Audit of Fire Door Insps Discovered Door 723F Identified During Weekly Insps as Unlocked But No Corrective Action Taken.Caused by Failure to Follow Procedures.Personnel Counseled + (ML20081K335)
- ML20081K337 + (ML20081K337)
- 05000338/LER-1983-022-03, Review of ASME XI Iwv Program Identified 126 Valves Exercised &/Or Stroke Timed at Incorrect Frequency.Caused by Implementation of Fragmented Program + (ML20081K342)
- ML20081K353 + (ML20081K353)
- ML20081K356 + (ML20081K356)
- PY-CEI-NRR-0079, Responds to Generic Ltr 83-28 Re Generic Implications of Salem ATWS Events.Util Cooperating W/Ge & BWR Owners Group to Determine Baseline for Equipment Classification & Vendor Interface.Addl Response Expected in Apr 1984 + (ML20081K361)