Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- 05000260/LER-1984-001, :on 840108,during RCIC Flow Testing,Rcic Failed to Reach Rated Flow in Required 30 S.Caused by Probable Setpoint Drift.Electronic Governor Control Sys Recalibr + (ML20079R421)
- ML20079R425 + (ML20079R425)
- ML20079R430 + (ML20079R430)
- ML20079R438 + (ML20079R438)
- ML20079R439 + (ML20079R439)
- 05000333/LER-1983-067-03, /03L-0:on 831228,while Conducting Surveillance Testing on RCIC Turbine Steam Line High Flow Switch 13-DPIS-84,setpoint Found Less Conservative than Required. Caused by Instrument Drift.Setpoint Corrected + (ML20079R447)
- ML20079R453 + (ML20079R453)
- ML20079R455 + (ML20079R455)
- ML20079R475 + (ML20079R475)
- 05000272/LER-1983-065-03, /03L-0:on 831226,containment Sump Level Monitoring Sys Indicated Unsubstantiated Leakage.Steam Generator 14 Secondary Handhole Cover Found Leaking.Cause Not Stated. Cover Repaired + (ML20079R476)
- ML20079R489 + (ML20079R489)
- 05000244/LER-1983-030-03, /03L-0:on 831216,actual Setpoint for Permissive Circuit P-10 Found Low at 8% Rather than 10% Full Power. Caused by Conflicting Tech Spec Requirements.Rev Proposed + (ML20079R490)
- ML20079R500 + (ML20079R500)
- ML20079R505 + (ML20079R505)
- ML20079R506 + (ML20079R506)
- 05000318/LER-1983-067-03, Charging Pump Discharge Relief Valve 23 Lifted.Caused by Damaged Disc.Disc Replaced. Further Testing Initiated to Correct Setpoint + (ML20079R516)
- 05000318/LER-1983-071-03, /03L-0:on 831219,during Return to Full Power, Power Dependent Insertion Limit (Pdil) for Group 4 Rods Found Inoperable.Caused by Setpoints Out of Tolerance at 35% Power.Pdil Readjusted + (ML20079R520)
- ML20079R526 + (ML20079R526)
- ML20079R540 + (ML20079R540)
- ML20079R543 + (ML20079R543)
- 05000334/LER-1983-042-03, /03L-0:on 831225,during Control Board Walkdown, Steam Flow Indications for Channel V on Two Separate Steam Lines Indicated 0.3 Mpph Higher than Other Indications. Caused by Frozen Sensing Lines.Lines Thawed + (ML20079R555)
- ML20079R559 + (ML20079R559)
- ML20079R575 + (ML20079R575)
- ML20079R577 + (ML20079R577)
- ML20079R588 + (ML20079R588)
- ML20079R596 + (ML20079R596)
- ML20079R602 + (ML20079R602)
- BSEP-83-1883, Forwards Reactor Containment Bldg Integrated Leak Rate Test. Test Failed Acceptance Criteria During Initial Performance.Next Integrated Leak Rate Test Scheduled for Fall 1983 Maint Outage + (ML20079R622)
- ML20079R628 + (ML20079R628)
- ML20079R632 + (ML20079R632)
- PY-CEI-NRR-0092, Forwards Amend 13 to FSAR + (ML20079R633)
- ML20079R644 + (ML20079R644)
- ML20079R647 + (ML20079R647)
- ML20079R652 + (ML20079R652)
- ML20079R658 + (ML20079R658)
- ML20079R659 + (ML20079R659)
- NRC-84-0011, Forwards Summary of Two Unresolved Issues Discussed in SER Section 8.3.1.2 Re Undervoltage Protection Analyses Corresponding to Sections 3 & 4 of Power Sys Branch Technical Position PSB-1 + (ML20079R661)
- ML20079R662 + (ML20079R662)
- PY-CEI-NRR-0054, Forwards Addl Info on Safety Relief Valve Piping & Quencher Device & safety-related Piping Supports,In Response to Questions 210.9,210.10 & 210.11 in NRC 821214 & s.Lateral Instability Will Not Occur + (ML20079R673)
- ML20079R674 + (ML20079R674)
- ML20079R677 + (ML20079R677)
- 05000333/LER-1983-065-03, /03L-0:on 831216,while Conducting Surveillance Testing of Main Steam Line Radiation Monitors,Setpoint of Monitor 17-RM-251C Found Less Conservative than Tech Spec. Caused by Instrument Drift.Setpoint Adjusted + (ML20079R684)
- ML20079R685 + (ML20079R685)
- ML20079R689 + (ML20079R689)
- 0CAN019409, Informs That D Mims Named to Position of Director,Licensing at ANO & That Mims Will Assume New Duties Effective 940201 + (ML20079R701)
- RBG-40006, Requests Issuance of 931208 Proposed Amend to License NPF-47 to Allow One Time Extension of Specific Instrumentation & Electrical Surveillance Interval to Support Current Fuel Cycle Outage Schedule Before 940216 + (ML20079R712)
- ML20079R720 + (ML20079R720)
- ML20079R731 + (ML20079R731)
- ML20079R735 + (ML20079R735)
- ML20079R737 + (ML20079R737)
- ML20079R740 + (ML20079R740)