- ML20079R232 + (ML20079R232)
- 05000317/LER-1983-069-03, /03L-0:on 831221,during Test of Reactor Trip Circuit Breaker (Tcb) Undervoltage (UV) Devices,Response Time of Tcb 2 & 6 UV Trip Devices Found Too Slow.Caused by Setpoint Drift.Uv Devices Replaced + (ML20079R233)
- ML20079R237 + (ML20079R237)
- ML20079R239 + (ML20079R239)
- ML20079R242 + (ML20079R242)
- ML20079R245 + (ML20079R245)
- ML20079R249 + (ML20079R249)
- ML20079R251 + (ML20079R251)
- ML20079R254 + (ML20079R254)
- ML20079R259 + (ML20079R259)
- ML20079R263 + (ML20079R263)
- ML20079R266 + (ML20079R266)
- 05000272/LER-1983-063-03, /03L-0:on 831214,axial Flux Difference Recorder & Monitor Alarm Not Monitored & Logged When Removed from Svc to Perform Routine Change of Target Flux Difference Value.Caused by Personnel Error + (ML20079R272)
- B11006, Forwards Amend 5 to Environ Rept - OL Stage,In Response to NRC 831007 Request for Addl Info + (ML20079R291)
- ML20079R298 + (ML20079R298)
- ML20079R305 + (ML20079R305)
- ML20079R307 + (ML20079R307)
- ML20079R308 + (ML20079R308)
- ML20079R310 + (ML20079R310)
- ML20079R312 + (ML20079R312)
- 05000255/LER-1983-037-01, /01T-0:on 830601,rack Mounted Circuit Board Replaced W/One from Stock Resulting in Total Loss of Valve Control During Restoration of Automatic Control of CV-0737A. Caused by Faulty Rack Mounted Circuit Board + (ML20079R325)
- ML20079R384 + (ML20079R384)
- ML20079R417 + (ML20079R417)
- 05000260/LER-1984-001, :on 840108,during RCIC Flow Testing,Rcic Failed to Reach Rated Flow in Required 30 S.Caused by Probable Setpoint Drift.Electronic Governor Control Sys Recalibr + (ML20079R421)
- ML20079R425 + (ML20079R425)
- ML20079R430 + (ML20079R430)
- ML20079R438 + (ML20079R438)
- ML20079R439 + (ML20079R439)
- 05000333/LER-1983-067-03, /03L-0:on 831228,while Conducting Surveillance Testing on RCIC Turbine Steam Line High Flow Switch 13-DPIS-84,setpoint Found Less Conservative than Required. Caused by Instrument Drift.Setpoint Corrected + (ML20079R447)
- ML20079R453 + (ML20079R453)
- ML20079R455 + (ML20079R455)
- ML20079R475 + (ML20079R475)
- 05000272/LER-1983-065-03, /03L-0:on 831226,containment Sump Level Monitoring Sys Indicated Unsubstantiated Leakage.Steam Generator 14 Secondary Handhole Cover Found Leaking.Cause Not Stated. Cover Repaired + (ML20079R476)
- ML20079R489 + (ML20079R489)
- 05000244/LER-1983-030-03, /03L-0:on 831216,actual Setpoint for Permissive Circuit P-10 Found Low at 8% Rather than 10% Full Power. Caused by Conflicting Tech Spec Requirements.Rev Proposed + (ML20079R490)
- ML20079R500 + (ML20079R500)
- ML20079R505 + (ML20079R505)
- ML20079R506 + (ML20079R506)
- 05000318/LER-1983-067-03, Charging Pump Discharge Relief Valve 23 Lifted.Caused by Damaged Disc.Disc Replaced. Further Testing Initiated to Correct Setpoint + (ML20079R516)
- 05000318/LER-1983-071-03, /03L-0:on 831219,during Return to Full Power, Power Dependent Insertion Limit (Pdil) for Group 4 Rods Found Inoperable.Caused by Setpoints Out of Tolerance at 35% Power.Pdil Readjusted + (ML20079R520)
- ML20079R526 + (ML20079R526)
- ML20079R540 + (ML20079R540)
- ML20079R543 + (ML20079R543)
- 05000334/LER-1983-042-03, /03L-0:on 831225,during Control Board Walkdown, Steam Flow Indications for Channel V on Two Separate Steam Lines Indicated 0.3 Mpph Higher than Other Indications. Caused by Frozen Sensing Lines.Lines Thawed + (ML20079R555)
- ML20079R559 + (ML20079R559)
- ML20079R575 + (ML20079R575)
- ML20079R577 + (ML20079R577)
- ML20079R588 + (ML20079R588)
- ML20079R596 + (ML20079R596)
- ML20079R602 + (ML20079R602)
- BSEP-83-1883, Forwards Reactor Containment Bldg Integrated Leak Rate Test. Test Failed Acceptance Criteria During Initial Performance.Next Integrated Leak Rate Test Scheduled for Fall 1983 Maint Outage + (ML20079R622)