- ML20079J703 + (ML20079J703)
- 3F0184-03, Responds to NRC Re Violations Noted in IE Insp Rept 50-302/83-27.Corrective Actions:Rcs Leakage Determination Satisfactorily Completed & Automated Tracking Program for Control Rod 3 Initiated + (ML20079J704)
- ML20079J706 + (ML20079J706)
- ML20079J707 + (ML20079J707)
- PLA-1436, Final Deficiency Rept Re Nonconformance of Bechtel Field Welding.Initially Reported on 821115.Training Sessions Conducted Re Welding QC Requirements & Procedures FP-G-24 & FP-W-1 Will Be Revised.Also Reported Per Part 21 + (ML20079J708)
- ML20079J711 + (ML20079J711)
- ML20079J716 + (ML20079J716)
- ML20079J723 + (ML20079J723)
- ML20079J730 + (ML20079J730)
- TXX-3591, Responds to IE Bulletin 82-01,Revision 1,Suppl 1, Alteration of Radiographs of Welds in Piping Subassemblies. All But Six Welds Will Meet Applicable Code Requirements + (ML20079J732)
- ML20079J733 + (ML20079J733)
- ML20079J735 + (ML20079J735)
- ML20079J736 + (ML20079J736)
- ML20079J741 + (ML20079J741)
- ML20079J742 + (ML20079J742)
- ML20079J745 + (ML20079J745)
- ML20079J748 + (ML20079J748)
- ML20079J750 + (ML20079J750)
- ML20079J751 + (ML20079J751)
- ML20079J752 + (ML20079J752)
- DCL-84-011, Forwards Attachments A,B & C to Rev 11 to Security Plan. Attachments Withheld (Ref 10CFR73.21) + (ML20079J753)
- SNRC-1008, Forwards List of Active Safety-Related Equipment at Qualification Level, Per SER Issue 8, Dynamic Qualification & Util 821123 Commitment + (ML20079J756)
- ML20079J760 + (ML20079J760)
- PLA-1439, Interim Deficiency Rept Re Design Verification of Max Permissible Lengths of Wire in Low Voltage Power & Control Circuits.Caused by Bechtel Failure to Follow Procedures. Final Rept by 830415.Also Reportable Per Part 21 + (ML20079J762)
- ML20079J764 + (ML20079J764)
- 05000416/LER-1982-033-99, /99X-1:on 820814,HPCS Diesel Generator 13 Started on Low Reactor Vessel Level Indication & Tripped on Overspeed.Caused by Faulty Tachometer Relay.Dynalco Relay Replaced & Sys Restored on 820818 + (ML20079J767)
- ML20079J772 + (ML20079J772)
- ML20079J774 + (ML20079J774)
- ML20079J776 + (ML20079J776)
- 05000335/LER-1982-060, Forwards LER 82-060/03L-0 + (ML20079J778)
- ML20079J784 + (ML20079J784)
- ML20079J787 + (ML20079J787)
- ML20079J792 + (ML20079J792)
- 05000335/LER-1982-060-03, /03L-0:on 821117,during Full Power Operation, Auxiliary Feedwater Flow Recorder 1B & Sigma Indicated Flow When Actual Flow Zero.Caused by Defective Force Motor Internal to Transmitter.Transmitter Replaced + (ML20079J799)
- ML20079J806 + (ML20079J806)
- ML20079J811 + (ML20079J811)
- ML20079J812 + (ML20079J812)
- ML20079J825 + (ML20079J825)
- AECM-82-605, Final Deficiency Rept PRD-82/33 Re Excessive Length of Capscrews in Standby Diesel Generator Air Start Valve Assembly Potentially Resulting in Valve Failure.Initially Reported on 820623.Deficiency Not Reportable Per Part 21 + (ML20079J827)
- PMNS20200252, Forthcoming Closed PRE-SUBMITTAL Meeting for the Future Submittal of Westinghouse Electric Company (Westinghouse) WCAP-18482-P, Westinghouse Advanced Doped Pellet Technology (Adopt) Fuel + (ML20079J831)
- ML20079J832 + (ML20079J832)
- 05000369/LER-1982-079, Forwards LER 82-079/03L-0 + (ML20079J834)
- ML20079J842 + (ML20079J842)
- 05000325/LER-1982-140, Forwards LER 82-140/03L-0 + (ML20079J845)
- 05000416/LER-1982-142, Forwards LER 82-142/99X-0 + (ML20079J857)
- 05000370/LER-1983-087-03, /03L-0:on 831215,while in Mode 1,during Monthly Functional Test Containment Hydrogen Analyzer Calibr, Analyzer 2B Could Not Be Satisfactorily Calibr.Caused by Faulty Connection on Amplifier Control Card + (ML20079J860)
- 05000321/LER-1982-090, Forwards LER 82-090/03L-0 + (ML20079J861)
- ML20079J865 + (ML20079J865)
- 05000416/LER-1982-142-99, /99X-0:on 821118,during Shutdown,Fire Barriers Broken in Control Room to Allow Cable Rerouting Per Approved Maint Work Order.Fire Watch Established.Fire Barriers Resealed Following Completion of Work + (ML20079J872)
- 05000321/LER-1982-090-03, /03L-0:on 821116,during Hydraulic Shock & Sway Arreston Insp & Functional Test Procedure,Snubber Found Inoperable.Caused by Component Failure Due to Worn Piston Rod Seal.Snubber Replaced & Returned to Operable Status + (ML20079J879)
- 05000369/LER-1982-079-03, /03L-0:on 821118,centrifugal Charging Pump 1A Declared Inoperable When Excessive Leakage from Pump Seals Noted.Caused by Pump Shaft Slinging Water Out of Seal Leakage Basin.Drain Line Cleared & Pump Returned to Svc + (ML20079J884)