- ML20076H636 + (ML20076H636)
- 05000339/LER-1983-065-03, /03L-0:on 830730-31 & 0803,rod Position Indicators Deviated from Group Demand Position by More than 12 Steps. Caused by Detector Temp Variations & Westinghouse Generic Problem.Indicators Recalibr + (ML20076H637)
- 05000324/LER-1983-034-01, /01T-0:on 830811,instrumentation Isolation Valves to Differential Pressure Sensing Switches 1-CAC-PDS-4222 & 4223 Found Closed.Caused by Inadequate Sys Valve Lineup. Valves Reopened + (ML20076H638)
- ML20076H643 + (ML20076H643)
- 05000369/LER-1983-064-03, /03L-0:on 830728,invalid Alarm Received on Fire Detection Zone Efa 136.Caused by High Humidity &/Or Dust Concentration in Honeywell Detector TC 100C Due to Leak from Valve 1NC-18.Detector Replaced + (ML20076H646)
- ML20076H648 + (ML20076H648)
- ML20076H651 + (ML20076H651)
- 05000261/LER-1983-008-03, /03L-0:on 830506,safety Injection Accumulator Level Transmitters Found Out of Calibr.Caused by Instrument Drift.Transmitters Recalibr & Replacement Mod Developed + (ML20076H653)
- ML20076H655 + (ML20076H655)
- 05000324/LER-1983-049-03, /03L-0:on 830511,main Steam Line Channel Instrument 2-D12-RM-K603D Found Actuating Out of Specified Tolerances.Caused by Zener Diode VR5 Failure in Channel Instrument drawer.VR5 Replaced + (ML20076H656)
- ML20076H658 + (ML20076H658)
- 05000366/LER-1983-034-01, /01T-0:on 830525,select Isotopes Identified But Omitted from Process Computer E BAR Library When Program Originally Initiated.Caused by Incorrect Computer Program. Library Will Be Corrected + (ML20076H659)
- ST-HL-AE-4909, Monthly Operating Repts for Sept 1994 for South Texas Project Electric Generating Station + (ML20076H662)
- ML20076H667 + (ML20076H667)
- 05000366/LER-1983-065-03, /03L-0:on 830721,QA Audit of Surveillance Procedures Revealed That Changes to Core Spray Logic Sys Functional Test Procedure HNP-2-3204 Made Improperly.Caused by Personnel Error.Rev Will Be Made Properly + (ML20076H669)
- ML20076H671 + (ML20076H671)
- 05000395/LER-1983-089-03, /03L-0:on 830815,while in Mode 1,temp Indicator Declared Inoperable Due to Erratic Indication Causing Loop B Overtemp Delta Temp to Alarm.Caused by Spiking Originating in Isolation Amplifier.Amplifier Replaced + (ML20076H678)
- PY-CEI-NRR-0050, Clarifies Commitment to Perform Addl Start & Load Qualification Testing on Standby Diesel Generators,As Outlined in SER Section 8.3.1.Total of 20 Addl Tests Will Be Conducted + (ML20076H679)
- 05000366/LER-1983-074-03, /03L-0:on 830726,during Maint,Hydrogen/Oxygen Analyzer 2P33-P001B Declared Inoperable Due to Erratic Operation.Caused by Worn Diaphragms in Diaphragm Pump.Worn Diaphragms Replaced + (ML20076H680)
- 05000339/LER-1983-064-03, /03L-0:on 830731,emergency Condensate Storage Tank Dropped Below 110,000 Gallons When Auxiliary Feedwater Pumps in Operation Following Reactor Trip.Caused by low-low Steam Generator Level Signal.Level Restored + (ML20076H683)
- 05000317/LER-1983-039-03, /03L-0:on 830722,during Normal Operation,Control Room Air Conditioner (Crac) 12 Compressor Tripped,Rendering Crac 12 Inoperable.Caused by Loose Condenser Fan Belts Tripping Compressor on High Discharge Pressure + (ML20076H684)
- ML20076H685 + (ML20076H685)
- 05000317/LER-1980-046-03, Containment RMS Pump Failed,Resulting in Loss of Containment Gaseous & Particulate Radiation Monitors.Caused by Corrosion & Subsequent Vane Wear/Failure Due to Humidity + (ML20076H686)
- 05000389/LER-1983-010-03, /03L-0:on 830511,power Lost to Side B Vital & Nonvital Buses.Caused by Opening Incorrect Breaker at Distribution Switchyard.Personnel Instructed on Importance of Proper Switching + (ML20076H689)
- ML20076H691 + (ML20076H691)
- ML20076H693 + (ML20076H693)
- B10802, Advises of QA Verification of Re Reevaluation of Steam Generator Tube Rupture Event in Support of Cycle 6 Operation.Verification Confirms Conclusions + (ML20076H697)
- ML20076H698 + (ML20076H698)
- ML20076H699 + (ML20076H699)
- ML20076H701 + (ML20076H701)
- ML20076H702 + (ML20076H702)
- 05000261/LER-1983-010-01, /01T-0:on 830525,review of Eddy Current Data Revealed 137 & 206 Defective Tubes Identified in Steam Generators B & C,Respectively.All Defective Tubes Taken Out of Svc + (ML20076H703)
- 05000348/LER-1983-041-03, /03L-0:on 830726,during Svc Water Bldg Battery Weekly Verification & on 830727,during Quarterly Verification,Train B Svc Water Battery Determined Inoperable Due to Cell 59 Having low-specific Gravity + (ML20076H704)
- 05000339/LER-1983-040-03, /03L-0:on 830518,during Refueling Outage,Type C Tests Revealed That 17 Containment Isolation Valves Exceeded Total Allowable Leakage.Caused by Dirt or Debris on Seating Surfaces.Seats Cleaned,Inspected & Repaired + (ML20076H705)
- ML20076H708 + (ML20076H708)
- 05000293/LER-1983-044-03, /03L-0:on 830725,inboard MOV-1301-16 Did Not Close During RCIC Surveillance Test.Outboard Isolation Valve Closed & Sys Declared Inoperable.Caused by Defective Belleville Spring Pack.Motor Operator Rebuilt + (ML20076H709)
- ML20076H710 + (ML20076H710)
- ML20076H711 + (ML20076H711)
- 05000318/LER-1980-047-03, During Normal Operation, Containment RMS Pump Failed Resulting in Loss of Containment Gaseous & Particulate Radiation Monitors.Caused by Corrosion.Pump Replaced + (ML20076H713)
- ML20076H716 + (ML20076H716)
- 05000416/LER-1983-064-01, /01T-0:on 830524,inconsistencies & Problems Associated W/Onsite Chlorine Storage Identified During Internal Review of Fsar.Caused by Lack of Administrative Controls + (ML20076H719)
- ML20076H721 + (ML20076H721)
- ML20076H725 + (ML20076H725)
- ML20076H726 + (ML20076H726)
- ML20076H728 + (ML20076H728)
- ML20076H733 + (ML20076H733)
- ML20076H736 + (ML20076H736)
- 05000220/LER-1983-016-03, /03L-0:on 830718,during Normal Operations,Main Steam Line Radiation Monitor 122 Declared Inoperable After Displaying Low Readings Since 830717.Caused by Defective Detector Output Connector on Monitor 122 + (ML20076H737)
- LIC-94-0177, Forwards Addl Info Requested to Assist in Closure of NRC GL 89-10 at Fort Calhoun Station + (ML20076H739)
- ML20076H749 + (ML20076H749)
- ML20076H750 + (ML20076H750)