Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML20075A033 + (ML20075A033)
- ML20076A043 + (ML20076A043)
- ML20076A194 + (ML20076A194)
- ML20076A546 + (ML20076A546)
- ML20076A547 + (ML20076A547)
- IA-19-033, Notice of Violation (NRC Investigation Report 1-2018-014) + (ML20076A548)
- ML20076A549 + (ML20076A549)
- ML20076A550 + (ML20076A550)
- ML20076A556 + (ML20076A556)
- ML20076A557 + (ML20076A557)
- ML20076A558 + (ML20076A558)
- ML20076A574 + (ML20076A574)
- SECY-20-0025, Weekly Information Report - Week Ending March 6, 2020 + (ML20076A575)
- ML20076A576 + (ML20076A576)
- ML20076A581 + (ML20076A581)
- IR 05000498/2020011 + (ML20076A582)
- ND-20-0235, ITAAC Closure Notification on Completion of ITAAC 2.2.05.07e (Index Number 880) + (ML20076A583)
- ML20076A586 + (ML20076A586)
- 05000416/LER-1983-093-03, /03L-0:on 830712 & 14,during Performance of 18- Month Calibr,Setpoints for PT N056A & Ps N654B Found Slightly Out of Allowable Limits.Caused by Instrument Drift.Instruments Readjusted + (ML20076A588)
- ML20076A590 + (ML20076A590)
- ML20076A597 + (ML20076A597)
- 05000327/LER-1983-100-03, /03L-0:on 830711,automatic Control Valve 1-PCV-3-122 for Train a Auxiliary Feedwater Sys Declared Inoperable Due to Failure to Open.Caused by Mispositioned Control Switch + (ML20076A605)
- 05000339/LER-1983-056-03, /03L-0:on 830711,containment Average Temp Exceeded 105 F for 12 Minutes.Caused by Mechanical Chiller Tripping on Low Compressor Oil Pressure.Steam Chiller Started & Lined Up to Containment Air Recirculation Coolers + (ML20076A614)
- ML20076A616 + (ML20076A616)
- ML20076A620 + (ML20076A620)
- ML20076A623 + (ML20076A623)
- ML20076A624 + (ML20076A624)
- ML20076A626 + (ML20076A626)
- 05000325/LER-1983-028-03, /03L-0:on 830709,during Testing,Eccs Actuation Instrument Time Delay Relay of 1A Core Spray Pump 1-E21-K16A Actuated at 13.92 Vs Specified Actuation Time of 14-15 S. Caused by Setpoint Drift.Relays Recalibr + (ML20076A627)
- ML20076A629 + (ML20076A629)
- 05000327/LER-1983-094-03, /03L-0:on 830712,steam Generator 4 Steam Flow (1-FI-1-28A) Indicated Zero.Caused by Air in Sense Lines. Lines Backfilled & Proper Output Verified + (ML20076A630)
- ML20076A633 + (ML20076A633)
- ML20076A635 + (ML20076A635)
- ML20076A636 + (ML20076A636)
- ML20076A639 + (ML20076A639)
- ML20076A640 + (ML20076A640)
- ML20076A642 + (ML20076A642)
- ML20076A644 + (ML20076A644)
- ML20076A645 + (ML20076A645)
- 05000395/LER-1983-081-03, /03L-0:on 830715,reactor Bldg Radiation Monitor RMA-2 Removed from Svc to Replace Filter.Caused by Thermal Overloads Tripping Due to Excessive Heat in Control Panel. Overloads Reset + (ML20076A648)
- ML20076A651 + (ML20076A651)
- ML20076A657 + (ML20076A657)
- 05000416/LER-1983-091-03, /03L-0:on 830728,review of Limiting Condition for Operation Rept Revealed Rept Closed Before Repair Work Completed.Caused by Personnel Error + (ML20076A660)
- 05000395/LER-1983-080-03, /03L-0:during Steam Generator Mod Outage of Mar to May 1983,surveillance of Certain Fire Doors Not Performed. Caused by Personnel Error.Plant Logs Revised + (ML20076A667)
- ML20076A668 + (ML20076A668)
- ML20076A674 + (ML20076A674)
- ML20076A678 + (ML20076A678)
- ML20076A679 + (ML20076A679)
- ML20076A683 + (ML20076A683)
- ML20076A691 + (ML20076A691)
- ML20076A699 + (ML20076A699)