Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML20072S853 + (ML20072S853)
- ML20072S856 + (ML20072S856)
- ML20072S861 + (ML20072S861)
- GO2-83-254, Notifies That Util Deferring Indefinitely,Plans to Install Continuous Nitrogen Supply Sys to Containment Electrical Penetrations,In Response to IE Bulletin 77-07,based on Industry Experience + (ML20072S863)
- ML20072S868 + (ML20072S868)
- LIC-94-0172, Lists Changes Required on Liquid Effluent - Summation of All Releases & Solid Waste & Irradiated Fuel Shipments Section of Effluent & Waste Disposal Annual Rept for 1992, as Requested in BNL + (ML20072S880)
- ML20072S881 + (ML20072S881)
- ML20072S883 + (ML20072S883)
- ML20072S887 + (ML20072S887)
- ML20072S889 + (ML20072S889)
- ML20072S893 + (ML20072S893)
- ML20072S899 + (ML20072S899)
- TXX-9420, Forwards CPSES Fsar,Amend 92 Detailed Description of Changes in Amend 92 + (ML20072S901)
- ML20072S903 + (ML20072S903)
- ML20072S906 + (ML20072S906)
- ML20072S912 + (ML20072S912)
- ML20072S914 + (ML20072S914)
- ML20072S921 + (ML20072S921)
- ML20072S935 + (ML20072S935)
- ML20072S936 + (ML20072S936)
- 05000237/LER-1983-017, Forwards LER 83-017/03L-0 + (ML20072S938)
- 2CAN049108, Submits Rept of Inservice Insps of Steam Generator Tubes Completed on 910403,consisting of Number of Steam Generator Tubes Plugged During Eighth Refueling Outage.Tabulation of Location of Plugged Tubes Encl + (ML20072S941)
- ML20072S943 + (ML20072S943)
- ML20072S950 + (ML20072S950)
- ML20072S951 + (ML20072S951)
- 05000237/LER-1983-017-03, /03L-0:on 830303,while Conducting Reactor Vessel Low Water Level Scram & Isolation Surveillance Dis 500-2, Low Level Isolation Switch LIS 2-263-57A Tripped Above Tech Spec Limit.Caused by Instrument Setpoint Drift.Switch Res + (ML20072S954)
- ML20072S958 + (ML20072S958)
- ML20072S959 + (ML20072S959)
- ML20072S962 + (ML20072S962)
- ML20072S964 + (ML20072S964)
- BSEP-94-0320, Forwards Rev 18 to Industrial Security Plan,Including Title & Section Changes & Realignment of Functions & Responsibilities to Reflect Recent Reorganization within CP&L Nuclear Generation Group.Rev Withheld + (ML20072S965)
- 0CAN049103, Revises 910121 Response to Violations Noted in Insp Repts 50-313/90-42 & 50-368/90-42.Corrective Actions:Procedure 1000.131, 10CFR50.59 Review Program Will Be Revised to Ensure Review Addresses Radiological Consequences + (ML20072S982)
- ML20072S984 + (ML20072S984)
- U-602337, Submits Response to GL 94-02, Long-Term Solution & Upgrade of Interim Operating Recommendations for Thermal Hydraulic Instabilities in Bwrs + (ML20072S989)
- 05000327/LER-1983-035, Forwards LER 83-035/03L-0 + (ML20072S993)
- ML20072S995 + (ML20072S995)
- ML20072S997 + (ML20072S997)
- 05000327/LER-1983-035-03, /03L-0:on 830304,feedwater Flow Channel Failed Low & Declared Inoperable.Caused by Permanent Compression Fitting Test Valve Blowing Off.Valve Properly Replaced + (ML20072T002)
- ML20072T008 + (ML20072T008)
- 05000324/LER-1983-030, Forwards LER 83-030/03L-0 + (ML20072T010)
- 05000324/LER-1983-030-03, /03L-0:on 830314,both Recirculation Pumps Tripped. Caused by Slight Disturbance in Common Ref Leg.Trip Signal Reset + (ML20072T014)
- ML20072T017 + (ML20072T017)
- 05000298/LER-1994-017, :on 940809,engineering Evaluation May Not Have Been Responsive to Intent or Potential Ramifications of Condition Addressed by In.Caused by Failure of REC Ci Valve.Evaluation of re-assessment Is ongoing.W/940908 + (ML20072T019)
- 05000259/LER-1980-011, Forwards Updated LER 80-011/01X-5 + (ML20072T025)
- 05000259/LER-1980-011-01, Analysis Indicated Potential Loss of Primary Containment During Hot Standby. Caused by Not Considering Probability of LOCA in Initial Plant Design.Mods to Ductwork Completed + (ML20072T029)
- ML20072T037 + (ML20072T037)
- 1CAN099401, LER 94-V01-00:on 940804,functional Test Procedure for Hydrogen Analyzer Was Not Adequate to Alert Plant Personnel.Caused by Personnel Oversight.Functional Test Procedure Has Been Revised + (ML20072T038)
- ML20072T045 + (ML20072T045)
- ML20072T049 + (ML20072T049)
- BECO-94-098, Application for Amend to License DPR-35,requesting Change to Reflect Standard TSs Re Maintenance of Filled Discharge Pipe + (ML20072T050)
- ML20072T052 + (ML20072T052)