Text
-
3*" "' %,
~
o UNITED STATES 5
NUCLEAR REGULATORY COMMISSION g
/
WASHINGTON, D.C. 20555-0001 f
- ..+
BALTIMORE GAS AND ELECTRIC COMPANY DOCKET NO. 50-317 CALVERT CLIFFS NUCLEAR POWER PLANT UNIT NO. 1 AMENDMEW TO FACILITY OPERATING LICENSE Amendment No.196 License No. DPR-53 1.
The Nuclear Regulatory Commission (the Commission) has found that:
A.
The application for amendment by Baltimore Gas and Electric Company (the licensee) dated June 8, 1994, complies with the standards and requirements of the Atomic Energy Act of 1954, as amended (the Act) and the Commission's rules and regulations set forth in 10 CFR Chapter I; B.
The facility will operate in conformity with the application, the provisions of the Act, and the rules and regulations of the Commission; C.
There is reasonable assurance (i) that the activities authorized by this amendment can be conducted without endangering the health and safety of the public, and (ii) that such activities will be conducted in compliance with the Commission's regulations; D.
The issuance of this amendment will not be inimical to the common defense and security or to the health and safety of the public; and E.
The issuance of this amendment is in accordance with 10 CFR Part 51 of the Commission's regulations and all applicable requirements have been satisfied.
2.
Accordingly, the license is amended by changes to the Technical Specifications as ir.dicated in the attachment to this license amendment, and paragraph 2.C.(2) of Facility Operating License No. DPR-53 is hereby amended to read as follows:
9409140281 940906 PDR ADOCK 05000317 P
pyg
l
- l (2) Techiaical Soecifications I
The Technical Specifications contained in Appendices A and B, as revised through Amendment No.196, are hereby incorporated in the license. The licensee shall operate the facility in accordance with i
the Technical Specifications.
3.
This license amendment is effective as of the date of its issuance and shall be implemented within 30 days.
FOR THE NUCLEAR REGULATORY COMMISSION Michael J. Case, Acting Director Project Directorate'I-1 Division of Reactor Projects - I/II Office of Nuclear Reactor Regulation
Attachment:
Changes to the Technical Specifications Date of Issuance: September 6, 1994 I
l l
t
[
c'
['
UNITED STATES NUCLEAR REGULATORY COMMISSION
{
~j WASHINGTON, D.C. 20666 0001 a,
a
+
~~
BALTIMORE GAS AND ELECTRIC COMPANY l
i DOCKET NO. 50-318
_j CALVERT CLIFFS NVCLEAR POWER PLANT. UNIT NO. 2
)
AMENDMENT TO FACILITY OPERATING LICENSE Amendment No.173 i
License No. DPR-69 1.
The Nuclear Regulatory Comission (the Comission) has found that:
I i
A.
The application-for amendment by Baltimore Gas -and Electric Company l
(the licensee) dated June 8, 1994, complies with the standards and requirements of the Atomic Energy Act of 1954, as amended (the Act) and the Comission's rules and regulations set forth in 10 CFR Chapter I; j
1 B.
The. facility will operate in conformity with the application,.
the provisions of the Act, and the rules and regulations of the i
. Commission; C.
There is reasonable assurance (1) that the activities authorized by this amendment can' be conducted without endangering the health and l
safety of the public, and (ii) that such ' activities will be conducted in compliance with the Comission's regulations; D.
The issuance of this amendment will' not be inimical to the common i
defense and security. or to.the health and safety of the public; and i
l E.
The issuance of this amendment is in accordance with 10 CFR Part 51 of the Comission's regulations and all applicable requirements I
have been satisfied.
2.
Accordingly, the license is amended by changes to the Technical Specifications as indicated in the attachment to this license amendment, and paragraph 2.C.2 of Facility Operating License No. DPR-69 is hereby amended to read as follows:
)
1 i
- (2) Technical Soecifications The Technical-Specifications contained in Appendices A and B, as revised through Amendment No.173, are hereby incorporated in the license. The licensee shall operate the facility in accordance with the Technical
+
Specifications.
3.
This license amendment is effective as of the date of its issuance and shall be implemented within 30 days.
FOR THE NUCLEAR REGULATORY COMMISSION W
Michael J. Ca e, Acting Director Project Directorate I-l l
Division of Reactor Projects - I/II Office of Nuclear Reactor Regulation
Attachment:
Changes to the Technical Specifications l
Date of Issuance: September 6, 1994 i
l' l
i l
l 1'.
l
\\
l ATTACHMENT TO LICENSE AMENDMENTS
]
l AMENDMENT NO. 196' FACILITY OPERATING LICENSE NO. DPR-53 i
AMENDMENT NO.173 ' FACILITY OPERATING LICENSE NO. DPR-69 DOCKET NOS. 50-317 AND 50-318 i
Revise Appendix A as follows:
Remove Paaes Insert Paaes Unit 1 Unit 1 I
3/4 6-19 3/4 6-19 Unit 2 Unit 2 3/4 6-15 3/4 6-15 l
l I
l 1
d i
[
3/4.6 CONTAINMENT SYSTEMS SURVEILLANCE REQUIRENENTS (Continued) l l
2.
Verifying that each unit operates for at least 15 minutes.
3.
Verifying a cooling water flow rate of > 2000 gpm to each cooling unit when the full flow service water outlet valves are fully open.
b.
At least once per REFUELING INTERVAL by verifying that each unit l
starts automatically on the appropriate ESFAS test signal.
i l
i l
I t
i i
l CALVERT CLIFFS - UNIT 1 3/4 6-19 Amendment No. 196
3/4.6 CONTAINMENT SYSTEMS SURVEILLANCE REQUIREMENTS (Continued) 2.
Verifying that each unit operates for at least 15 minutes, i
3.
Verifying a cooling water flow rate of > 2000 gpm to each cooling unit when the full flow service water outlet valves are fully open, b.
At least once per REFUELING INTERVAL by verifying that each unit l
starts automatically on the appropriate ESFAS test signal.
l l
l l
l l
CALVERT CLIFFS - UNIT 2 3/4 6-15 Amendment No. 173 l