- 05000271/LER-1978-031, Forwards LER 78-031/03L-0 + (ML20064E305)
- ML20064E307 + (ML20064E307)
- 05000271/LER-1978-031-03, /03L-0 on 781016:weekly Review of Completed Surveillance Test Following Plant Startup Noted That Monthly Hydrogen Detector Functional Test Was Not Performed Due to Personnel Error + (ML20064E310)
- ML20064E311 + (ML20064E311)
- 05000271/LER-1994-001, :on 940106,nonconservative TS Setpoint Range Applied to Calibr Procedure for Rod Block Monitor auto- Bypass Feature.Caused by Personnel Error.Setpoint Change Request Processed & OP 4304 Revised + (ML20064E313)
- ML20064E316 + (ML20064E316)
- ML20064E321 + (ML20064E321)
- ML20064E322 + (ML20064E322)
- 05000271/LER-1978-032, Forwards LER 78-032/03L-0 + (ML20064E323)
- 05000271/LER-1978-032-03, /03L-0 on 781014:during Surveillance Test of Main Steam Isolution Valves,V2-86C Closed in 2.6 Seconds Rather than 3-5 Seconds Req in Tech Spec 4.7.D.1.a.1.Caused by Closing Speed Control Valve Coming Loose from Actuator + (ML20064E328)
- 05000325/LER-1978-083, Forwards LER 78-083/03L-0 + (ML20064E332)
- 05000325/LER-1978-083-03, /03L-0 on 781014:RCIC Turbine Was Tripped on Manual Overspeed for Training Purposes & Turbine control- Stop Valve E51-V8 Would Not Reset.Caused by Improperly Worn Adjusted Reset Lever + (ML20064E337)
- 05000325/LER-1978-078, Forwards LER 78-078/03L-0 + (ML20064E340)
- 05000325/LER-1978-077, Forwards LER 78-077/03L-0 + (ML20064E345)
- 05000325/LER-1978-078-03, /03L-0 on 781105:Control Oper Received Control Rod Drift Alarm for Rod 10-31.When Rod Position Display Was Selected,A False 3 Was Superimposed on Actual Rod Position Due to Aground on the Rpls Probe + (ML20064E349)
- 05000325/LER-1978-077-03, /03L-0 on 781006:condensate Storage Tank Level Switch E41-LS-N003 Found Out of Calibration During Periodic Condensate Storage Tank Low Level Channel.Caused by Instru Drift + (ML20064E354)
- ML20064E358 + (ML20064E358)
- ML20064E359 + (ML20064E359)
- ML20064E363 + (ML20064E363)
- ML20064E370 + (ML20064E370)
- ML20064E380 + (ML20064E380)
- ML20064E385 + (ML20064E385)
- ML20064E395 + (ML20064E395)
- ML20064E401 + (ML20064E401)
- ML20064E405 + (ML20064E405)
- ML20064E406 + (ML20064E406)
- ML20064E417 + (ML20064E417)
- ML20064E419 + (ML20064E419)
- ML20064E424 + (ML20064E424)
- 05000259/LER-1994-001-01, :on 940304,EECW Pump A3 Inadvertently Auto Started During Performance of SI O-SI-4.2.B.-67.Caused by Personnel Error.Electrical Maint Procedures Will Be Revised. Walkdown of 4 Kv Shutdown Will Be Performed + (ML20064E426)
- 05000334/LER-1978-055, Forwards LER 78-055/03L-0 + (ML20064E427)
- 05000334/LER-1978-055-03, /03L-0 on 781013:channel N41 Rate Trip Set at 11.8% in 2.2 Seconds Rather than Limit of 5.5% in 2 Seconds. Caused by Inadvertent Readjustment or Improper Calibr of the Setpoint + (ML20064E432)
- 05000338/LER-1978-026, Forwards LER 78-026/99X-1 & 78-089/03X-1 + (ML20064E435)
- 05000338/LER-1978-026-99, /99X-1 on 780413:with All Rods Out at Beginning of Core Life,Hot Zero Pwr Moderator Temp Coefficient Revealed It Was More Positive than 0 Delta K/K/F in Tech Spec,Due to Positive Mtc for the all-rods-out Configuration + (ML20064E438)
- 05000338/LER-1978-089-03, /03X-1 on 780915:during Periodic Test,A Bistable (FC-1485 in Protec Channel Iv)Associated W/Hi Steamline Flow S.I.Actuation Failed to Trip,Due to Defective Bistable Card + (ML20064E442)
- ML20064E443 + (ML20064E443)
- ML20064E445 + (ML20064E445)
- 05000325/LER-1978-082, Forwards LER 78-082/01T-0 + (ML20064E448)
- ML20064E449 + (ML20064E449)
- ML20064E453 + (ML20064E453)
- ML20064E454 + (ML20064E454)
- 05000325/LER-1978-082-01, /01T-0 on 781101:util Was Informed by NRR of Nonconformance w/10CFR50 Append a Gen Design Criteria 54 & 56.Two Reactor bldg-to-torus Vacuum Breaker Lines Have Never Had Design Review by Nrc.Tech Spec Change Effective 781108 + (ML20064E458)
- ML20064E460 + (ML20064E460)
- ML20064E461 + (ML20064E461)
- ML20064E462 + (ML20064E462)
- 05000334/LER-1978-056, Forwards LER 78-056/03L-0 + (ML20064E465)
- ML20064E466 + (ML20064E466)
- ML20064E471 + (ML20064E471)
- 05000334/LER-1978-056-03, /03L-0 on 781011:vent Exhaust Monitor RM-VS-101 Removed from Svc for Grab Samples.Sample Not Taken for One Day Due to Personnel Error.(For Ltr See ANO 7811170172.) + (ML20064E474)
- RBG-40325, Forwards Endorsements 57,58,59 & 60 to Nelia Policy NF-0286, Endorsements 49,50,51 & 52 to Maelu Policy MF-0119, Endorsements 16 & 17 to Nelia & Maelu Policies N-0100 & M-0100,respectively & Rev 11 to Nelia Policy NW-0178 + (ML20064E475)
- ML20064E476 + (ML20064E476)