Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- 05000255/LER-1982-016, Forwards LER 82-016/03L-0 + (ML20063D358)
- 05000368/LER-1982-019, Forwards LER 82-019/03L-0 + (ML20063D364)
- ML20063D374 + (ML20063D374)
- ML20063D382 + (ML20063D382)
- ML20063D384 + (ML20063D384)
- ML20063D390 + (ML20063D390)
- ML20063D392 + (ML20063D392)
- ML20063D395 + (ML20063D395)
- ML20063D399 + (ML20063D399)
- 05000267/LER-1982-023, Forwards LER 82-023/03L-0.Detailed Event Analysis Encl + (ML20063D402)
- ML20063D404 + (ML20063D404)
- RBG-39961, Forwards Results of Investigation Held Prior to 940106 Security Enforcement Conference.Understand That Rept Prepared by Shaw,Pittman,Potts & Trowbridge for Util Will Be Made Part of Record of Enforcement Conference.W/O Encl + (ML20063D408)
- ML20063D411 + (ML20063D411)
- 05000247/LER-1982-018, Forwards LER 82-018/03L-0 + (ML20063D412)
- ML20063D416 + (ML20063D416)
- 05000267/LER-1982-023-03, /03L-0:on 820527,primary Coolant Oxidants Exceeded Tech Specs AC 7.5.2(b)2 on Three Separate Occasions.Caused by Gradual Ingress of Moisture & Oxidants.Moisture & Oxidant Offgassed from Core.Power & Temp Reduced + (ML20063D417)
- 05000247/LER-1982-018-03, /03L-0:on 820517,loss of Feed to Two Weld Channel Valves & Two Sample Valves Experienced.Caused by Blown Fuse Due to Failed SOV 1534 Coil.Fuse Replaced.Grease Removed from Vent Port & Coil Replaced on SOV 1534 + (ML20063D422)
- 05000311/LER-1982-043, Forwards LER 82-043/03L-0.Detailed Event Analysis Encl + (ML20063D425)
- ML20063D427 + (ML20063D427)
- 05000311/LER-1982-043-03, /03L-0:on 820524,during Routine surveillance,16 Valves Discovered Missing from Surveillance Procedures SP(o)4.6.1.1A1.Valves Omitted from Surveillance inadvertently.In-depth Investigation of Piping Sys Underway + (ML20063D431)
- ML20063D435 + (ML20063D435)
- 05000247/LER-1982-019, Forwards LER 82-019/03L-0 + (ML20063D438)
- ML20063D443 + (ML20063D443)
- ML20063D446 + (ML20063D446)
- 05000247/LER-1982-019-03, /03L-0:on 820517,auxiliary Boiler Feed Pump 23 Failed.Caused by Damaged Thrust Bearing Due to Equalizing Line Check Valve Hanging Up,Negating Positioning Control of Balancing Drum.Bearing Replaced & Check Valves Removed + (ML20063D449)
- ML20063D450 + (ML20063D450)
- ML20063D452 + (ML20063D452)
- ML20063D454 + (ML20063D454)
- ML20063D456 + (ML20063D456)
- ML20063D459 + (ML20063D459)
- ML20063D460 + (ML20063D460)
- ML20063D463 + (ML20063D463)
- ML20063D466 + (ML20063D466)
- ML20063D470 + (ML20063D470)
- ML20063D478 + (ML20063D478)
- 05000333/LER-1981-066, Forwards LER 81-066/03X-1 + (ML20063D479)
- 05000333/LER-1981-066-03, /03X-1:on 810816,during Routine Startup operations,100 F Heatup/Rate Found Below Limit.Caused by Personnel Error.Evaluation Performed.No Effect on Reactor Vessel Life.Personnel Counseled + (ML20063D491)
- NRC-94-4059, Forwards Westinghouse Responses to NRC Requests for Addl Info on AP600 from Ltrs of 931027,1102 & 30.Listing of NRC Requests for Addl Info Responded to in Ltr Contained in Attachment a + (ML20063D492)
- 05000311/LER-1982-047, Forwards LER 82-047/03L-0.Detailed Event Analysis Encl + (ML20063D495)
- ML20063D497 + (ML20063D497)
- 05000311/LER-1982-047-03, /03L-0:on 820530,while Entering Containment,Maint Personnel Unable to Shut Inner Door on 100-ft Elevation Containment Air Lock.Caused by Maladjusted Latch Linkage. Linkage Adjusted.No Further Action Necessary + (ML20063D504)
- ML20063D509 + (ML20063D509)
- 05000263/LER-1991-009, :on 910427,determined That Cables for Secondary Containment Isolation Damper Solenoids & SGTS Components Did Not Meet Separation Requirements in Several Locations.Caused by Personnel Error.Solenoid Cables Rerouted + (ML20063D514)
- 05000272/LER-1982-035-99, /99X-0:on 820526 & 0603,fire Pump 2 Failed to Start.Apparently Caused by Control Circuit Malfunction. Investigation Underway.Hope Creek Fire Suppression Sys Will Be Used in Interim + (ML20063D516)
- 05000237/LER-1982-017, Forwards LER 82-017/03L-0 + (ML20063D521)
- 05000237/LER-1982-017-03, /03L-0:on 820529,during Routine Shutdown operations,source-range Monitor 24 Failed to Select & Insert.Caused by Select Switch Contacts Failing to Operate. Switch Replaced,Monitor Tested & Returned to Svc + (ML20063D524)
- ML20063D526 + (ML20063D526)
- 05000331/LER-1980-065, Forwards Updated LER 80-065/03X-1 + (ML20063D529)
- 05000370/LER-1993-008-03, :on 931227,Unit 2 Reactor Trip Occurred Due to Loss of off-site Power.Caused by Unanticipated Environ Interaction,Vendor Fabrication Deficiency,Deficient Documentation & Inadequate Surveillance Program + (ML20063D531)
- 05000331/LER-1980-065-03, During Surveillance Testing Suppression Chamber Purge Inlet Valve CV-4308 Would Not Cycle,As Required by Tech Spec 3.7.D.1.Caused by Sticking Operator Mfg by Miller Fluid Power + (ML20063D534)
- 05000334/LER-1982-013, Forwards Updated LER 82-013/99X-1 + (ML20063D540)