Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML20058L958 + (ML20058L958)
- ML20058L959 + (ML20058L959)
- 05000443/LER-1990-018, :on 900705,reactor Trip W/Turbine Trip Occurred.Caused by Contact Closure of Electrohydraulic Control Oil Pressure Switches Satisfying Two Out of Three Logic.Pressure Switches Relocated + (ML20058L960)
- 05000325/LER-1990-012-01, :on 900705,determined That 18-month Surveillance on Battery 1A-1 Exceeded Surveillance Time Interval.Probably Caused by Tech Spec Change & Rescheduling of Outage.Personnel Counseled + (ML20058L963)
- ML20058L964 + (ML20058L964)
- 05000440/LER-1990-016, :on 900710,condensate Storage Tank Level Low Actuation Instrumentation Failure Resulted in HPCS Shift. Caused by Component Failure.Rosemount Master Trip Unit Replaced + (ML20058L966)
- 05000354/LER-1990-011-02, :on 900703,determined That Control Room B Emergency Filtration (CREF) Sys Had Been Run on CREF Train A.Caused by Personnel Error.Nuclear Shift Supervisors Involved Counseled + (ML20058L969)
- ML20058L970 + (ML20058L970)
- ML20058L971 + (ML20058L971)
- ML20058L972 + (ML20058L972)
- ML20058L973 + (ML20058L973)
- ML20058L975 + (ML20058L975)
- ML20058L977 + (ML20058L977)
- ML20058L979 + (ML20058L979)
- 05000289/LER-1990-006-01, :on 900702,control Room Operator Depressed Manual RB High Pressure Actuation Pushbutton During Testing Causing Emergency Safeguards Actuation.Caused by Personnel Error.Personnel Reinstructed + (ML20058L980)
- ML20058L982 + (ML20058L982)
- ML20058L983 + (ML20058L983)
- ML20058L984 + (ML20058L984)
- ML20058L987 + (ML20058L987)
- ML20058L989 + (ML20058L989)
- L-93-058, Forwards Response to NRC 931110 RAI Re Decommissioning Funding Plan Submitted on 930528 + (ML20058L990)
- ML20058L991 + (ML20058L991)
- ML20058L994 + (ML20058L994)
- ML20058L996 + (ML20058L996)
- ML20058L998 + (ML20058L998)
- ML20058M000 + (ML20058M000)
- ML20058M002 + (ML20058M002)
- ML20058M004 + (ML20058M004)
- 05000416/LER-1990-010-01, :on 900706,error Discovered in Evaluation Used to Demonstrate Adequacy of Svc Water Flow to HPCS Pump Room Cooler.Matls Nonconformance Rept Generated to Document Discrepancy + (ML20058M006)
- ML20058M007 + (ML20058M007)
- LIC-93-0292, Special Rept:On 931026,Fire Protection Impairment Permit (Fpip) 3619 Initiated for Containment Fire Detection Zone 17 to Support Troubleshooting & Repair of Zone 17 Detector.Fire Watch Established Until Affected Zones Cleared + (ML20058M008)
- ML20058M009 + (ML20058M009)
- ML20058M011 + (ML20058M011)
- ML20058M012 + (ML20058M012)
- ML20058M013 + (ML20058M013)
- IR 015000033/1993001 + (ML20058M016)
- ML20058M017 + (ML20058M017)
- ML20058M019 + (ML20058M019)
- ML20058M021 + (ML20058M021)
- ML20058M030 + (ML20058M030)
- ML20058M033 + (ML20058M033)
- ML20058M035 + (ML20058M035)
- ML20058M036 + (ML20058M036)
- ML20058M040 + (ML20058M040)
- ML20058M041 + (ML20058M041)
- NLS9000196, Responds to Violations Noted in Insp Rept 50-298/90-09. Corrective Actions:To Ensure Future Clarity,District Will Revise Procedures to Clearly Indicate Acceptability of Okonite in Instrumentation Applications + (ML20058M042)
- IR 05000313/1993031 + (ML20058M043)
- ML20058M045 + (ML20058M045)
- ML20058M048 + (ML20058M048)
- ML20058M049 + (ML20058M049)
- ET-NRC-93-4026, Forwards 8mm Data Cartridge Containing Wordperfect Files for Listed AP600 Documents,Listing of Electronic Files & Instructions on Retrieval & Install Using Sun Workstation. Proprietary Portion of Document Sent to Westinghouse + (ML20058M052)