- RBG-13-032, Interim Deficiency Rept Re Installation of Nonseismic Pipe Supports Over Category I Components in Control Bldg, Initially Reported on 820615.Investigation Continuing. Next Rept Will Be Submitted by 820902 + (ML20055B710)
- ML20055B713 + (ML20055B713)
- ML20055B714 + (ML20055B714)
- 05000325/LER-1982-064, Forwards LER 82-064/03L-0 + (ML20055B715)
- ML20055B717 + (ML20055B717)
- ML20055B718 + (ML20055B718)
- 05000325/LER-1982-064-03, /03L-0:on 820615,post-accident Monitoring Control Room Recorder/Indicator 1-CAC-AR-1259 Erraticaly Indicated Drywell Oxygen Concentrations.Caused by Erratic Instrument Output Due to Unknown Causes.Unit Replaced + (ML20055B720)
- 05000280/LER-1979-045-01, Air Would Not Flow Through Filters If Consequence Limiting Safeguards hi-hi Signal Removed from Control Circuit of Safeguards Area Exhaust Ventilation Dampers.Caused by Design Deficiency + (ML20055B721)
- IR 05000482/1981012 + (ML20055B722)
- 05000280/LER-1980-059-01, Util Informed of Potential for Loss of Auxiliary Feedwater Flow Following Steamline Rupture.Caused by Original Design Allowing Pump Runout & Subsequent Tripping of Sys Pump Motors + (ML20055B724)
- ML20055B725 + (ML20055B725)
- ML20055B726 + (ML20055B726)
- ML20055B727 + (ML20055B727)
- IR 05000312/1982026 + (ML20055B728)
- ML20055B729 + (ML20055B729)
- ML20055B730 + (ML20055B730)
- 05000369/LER-1982-053, Forwards LER 82-053/03L-0.Detailed Event Analysis Encl + (ML20055B731)
- ML20055B733 + (ML20055B733)
- ML20055B735 + (ML20055B735)
- 05000369/LER-1982-053-03, /03L-0:on 820624,during Plant Cooldown,Static Inverter Evia Malfunctioned,Causing RHR Sys Negative Declaration Isolation Valve to Close.Caused by Component Failure of Solidstate Controls,Inc Static Inverter + (ML20055B736)
- 05000280/LER-1982-073-03, /03L-0:on 820622,charging Pump Svc Water Pump 1-SW-P-10B Failed to Develop Adequate Discharge Pressure. Caused by Insufficient Npsh.Svc Water to Chillers Throttled to Provide Sufficient NPSH + (ML20055B737)
- 05000280/LER-1982-071-03, /03L-0:on 820618,motor Operated valve-1536 Pressure Power Operated Relief Block Valve Was Cycled Open But Failed to Close Fully,Remotely or Manually.Cause Undetermined.Valve Closed Electrically + (ML20055B738)
- 05000348/LER-1982-030, Forwards LER 82-030/03L-0 + (ML20055B739)
- 05000267/LER-1982-026, Forwards LER 82-026/03L-0.Detailed Event Analysis Encl + (ML20055B741)
- ML20055B743 + (ML20055B743)
- 05000267/LER-1982-026-03, /03L-0:on 820615,total Primary Coolant Oxidants Exceeded Limiting Conditions for Operation on Two Occasions. Caused by Water in Core Due to Sudden Pressure Surge from Loss of 480-volt Essential Busses.Concentrations Reduced + (ML20055B745)
- ML20055B746 + (ML20055B746)
- ML20055B748 + (ML20055B748)
- ML20055B750 + (ML20055B750)
- ML20055B751 + (ML20055B751)
- ML20055B753 + (ML20055B753)
- ML20055B754 + (ML20055B754)
- ML20055B756 + (ML20055B756)
- ML20055B757 + (ML20055B757)
- ML20055B758 + (ML20055B758)
- 05000280/LER-1982-072, Forwards LER 82-072/03L-0 & 82-068/03L-0 + (ML20055B759)
- ML20055B761 + (ML20055B761)
- ML20055B762 + (ML20055B762)
- ML20055B766 + (ML20055B766)
- L-82-284, Final Deficiency Rept Re Steam Generator 2A 1-inch Nozzles, Initially Reported 820217.Deficiency Not Considered Reportable Per 10CFR50.55e + (ML20055B768)
- IR 05000285/1982011 + (ML20055B769)
- ML20055B770 + (ML20055B770)
- ML20055B772 + (ML20055B772)
- ML20055B773 + (ML20055B773)
- 05000260/LER-1982-019, Forwards LER 82-019/03L-0 + (ML20055B775)
- 05000339/LER-1982-036, Forwards LER 82-036/03L-0 + (ML20055B779)
- 05000260/LER-1982-019-03, /03L-0:on 820618,while Performing SI-2 (Rod Notch Exercise),Flow Bias Comparator Trip Prevented Rod Withdrawal.Caused by Gemac 563-02 Proportional Amplifier (FQ-68-81) Drifting Upscale.Amplifier Replaced + (ML20055B782)