Interim Deficiency Rept Re RCS Attached Piping,Initially Reported on 801113.LOCA Anchor Displacement Reanalysis Progress Rept 4 Encl.Subsequent Interim Repts Will Be Provided Semiannually
ML20055B730
Person / Time
Site: Washington Public Power Supply System
Issue date: 07/02/1982
From: Mazur D
WASHINGTON PUBLIC POWER SUPPLY SYSTEM
To: Faulkenberry R
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION V)
References
10CFR-050.55E, 10CFR-50.55E, GO1-82-0414, GO1-82-414, NUDOCS 8207230213
Download: ML20055B730 (3)


Text

-_-

Docket Nos. 50-460/513

~"M 50.55(e) Report

/

{IMO Washington Public Power Supply System P.O. Box 968 3000 GeorgeWashington Way Richland, Washington 99352 (509)372-5000

,la,,a 3,,

July 2, 1982 G01-82-0414 ftg r.

m. ;.

Nuclear Regulatory Commission Region V 1450 Maria Lane, Suite 210 Walnut Creek, California 94596 Attention:

Mr. R. H. Faulkenberry Chief, Reactor Construction Projects Branch

Subject:

NUCLEAR PROJECTS 1 & 4 DOCKET NOS. 50-460 AND 50-513 POTENTIALLY REPORTABLE CONDITION RCS ATTACHED PIPING

Reference:

1)

Telecon TJ Houchins, Supply System to DF Kirsch, Region V Nuclear Regulatory Commission, dated November 13, 1980 2)

G0-1-80-380, DW Mazur, to RH Engelken, Director dated December 12, 1980 3)

G0-1-81-198, DW Mazur to RH Faulkenberry, dated July 2, 1981 4)

G0-1-81-331, DW Mazur to RH Faulkenberry, dated October 5, 1981 5)

G0-1-82-03, DW Mazur to RH Faulkenberry, dated January 6, 1982 6)

G0-1-82-Oll8, RW Root to RH Faulkenberry, dated April 2, 1982 In reference 1), the Supply System informed your office of a potentially l

reportable deficiency under 10CFR50.55(e) and references 2), 3), 4),

j

5) and 6) were interim reports on the subject condition.

l In reference 3), the Supply System committed to providing quarterly j

updates on the status of the subject deficiency. Our previous quarterly

)

updates have included two (2) Attachments. Attachment A was a detailed I

l recap of the problem and Attachment B identified the systems to be re-analyzed and the associated percent complete.

Because Attachment A does not change between reports, it is no longer included as part of our status reports. However, we will continue to provide semiannual updates to Attachment B.

Should circumstances arise where we find it necessary to amend Attachment A, we will so notify your office.

c B207230213 e20702 PDR ADOCK 05000460 S

PDR 82 57

~,

1 i

R. H. Faulkenberry July 2, 1982 RCS Attached Piping G01-82-0414 Page 2 It is still not possible to provide a final completion date for the subject design analysis; therefore, the Supply System will, as previously stated above, continue to provide your office with interim status reports.

Based on the current WNP-1 construction slowdown, the level of effort expended to complete the analysis verification and redesign has been reduced. As a result, the Supply System interim reports will be provided i

on a six month basis.

If you have an questions or desire further information, please advise.

/

W D. W. Mazur Acting Program Director RWR:MER:lm Attachment cc: CR Bryant, BPA (399)

JP Laspa, Bechtel (860)

V. Mani, UE&C (897)

A Toth, NRC i

V. Stello, Director of Inspection, NRC FDCC (899) i

ATTACl! MENT 3 LOCA ANCHOR DISPLACEMENT REANALYSIS PROGRESS REPORT No. 4 6/25/82 System Total

% of Work Remarks Completed MSS 75 LAD reanalysis for these lines has been completed and the pipe stresses and support loads for this load-case must be combined with other load-cases and the results evaluated.

(

FWS LAD reanalysis for these lines has been 75 completed and the pipe stresses and support FWA loads for this load-case must be, combined with other load-cases and the results evaluated.

DHR Pipe stresses have increased;,however, they Drop Line 100 are within acceptable limits.

Due to increased loads resulting frca the dynamic reanalysis, four (4) supports out of nine (9) found to be unacceptable and must be modified.

CFS &

LAD reanalysis for these lines has been 75 DilR (LPI) completed and the pipe stresses and support loads for this load-case must be combined with other load-cases and the results evaluated.

MUS (llPI) 0 Time history data is required from B&W.

Reanalysis has not started.

Instrument 20 Time history data has been received from MW.

Lines (10)

Reanalysis has ; tarted.