Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML20052J002 + (ML20052J002)
- ML20052J004 + (ML20052J004)
- ML20052J006 + (ML20052J006)
- ML20052J008 + (ML20052J008)
- PNO-III-82-048, on 820518,individual at New Brighton,Mn, Facility May Have Received 100-200 Rem Dose to Hand When Touching 150-Ci Cs-137 Source in Hot Cell.Individual TLD Finger Dosimeters Submitted for Processing + (ML20052J009)
- IR 05000508/1982006 + (ML20052J010)
- ML20052J011 + (ML20052J011)
- ML20052J012 + (ML20052J012)
- ML20052J014 + (ML20052J014)
- ML20052J015 + (ML20052J015)
- ML20052J017 + (ML20052J017)
- IR 05000397/1982006 + (ML20052J018)
- ML20052J019 + (ML20052J019)
- 05000316/LER-1982-035-03, /03L-0:on 820413,flow Path from Boric Acid Transfer Pumps to Charging Pump Suction Isolated to Enable Repairs on Flow Instrument Isolation Valve Cs-486.Valve Leak Caused by Diaphragm Failure.Diaphragm Replaced + (ML20052J020)
- ML20052J021 + (ML20052J021)
- ML20052J022 + (ML20052J022)
- ML20052J023 + (ML20052J023)
- 05000316/LER-1982-036-03, /03L-0:on 820422,flow Path from Bast to RCS Isolated in Order to Unplug Bast Recirculation Line.Caused by Repair to Boric Acid Recirculation Line Due to Pluggage. Line Unplugged & Flow Path Restored + (ML20052J024)
- ML20052J025 + (ML20052J025)
- ML20052J027 + (ML20052J027)
- 05000316/LER-1982-037-03, /03L-0:on 820423,while Establishing Clearance to Repair Valve,Flow Path from Boric Acid Tanks to Charging Pumps Suction Removed from Svc.Caused by Failed Diaphragm on Filter Isolation Valve.New Diaphragm Installed + (ML20052J028)
- ML20052J029 + (ML20052J029)
- ML20052J030 + (ML20052J030)
- ML20052J031 + (ML20052J031)
- ML20052J032 + (ML20052J032)
- ML20052J033 + (ML20052J033)
- 05000318/LER-1982-018, Forwards LER 82-018/03L-0 + (ML20052J035)
- 05000245/LER-1982-009, Forwards LER 82-009/03L-0.Detailed Event Analysis Encl + (ML20052J037)
- ML20052J039 + (ML20052J039)
- ML20052J041 + (ML20052J041)
- 05000318/LER-1982-018-03, /03L-0:on 820417,control Element Assembly 21 Dropped Into Core After Electricians Inadvertently Disconnected Power,Resulting in Pressurizer Level Deviation Exceeding Tech Spec Limit.Caused by Personnel Error + (ML20052J042)
- 05000245/LER-1982-009-03, /03L-0:on 820412,while Performing High Pressure Scram & Containment Isolation Functional Calibr Test, Pressure Switch 2206-1612D Failed to Trip at Desired Setpoint.Caused by Setpoint Drift.Switch Replaced + (ML20052J043)
- ML20052J046 + (ML20052J046)
- ML20052J048 + (ML20052J048)
- IR 05000089/1982001 + (ML20052J052)
- ML20052J054 + (ML20052J054)
- 05000285/LER-1982-009, Forwards LER 82-009/03L-0 + (ML20052J057)
- 05000285/LER-1982-009-03, /03L-0:on 820411,while Exchanging Component Cooling Water Heat Exchangers,Associated Outlet Valves HCV-490B,HCV-491B & HCV-492B Failed to Open.Cause Not stated.HCV-491B Reassembled & Tested + (ML20052J063)
- ML20052J068 + (ML20052J068)
- ML20052J069 + (ML20052J069)
- ML20052J073 + (ML20052J073)
- ML20052J076 + (ML20052J076)
- ML20052J077 + (ML20052J077)
- IR 05000312/1982016 + (ML20053A000)
- ML20053A003 + (ML20053A003)
- ML20053A004 + (ML20053A004)
- IR 05000312/1982013 + (ML20053A007)
- ML20053A008 + (ML20053A008)
- ML20053A009 + (ML20053A009)
- 05000364/LER-1981-039, Forwards LER 81-039/03L-0 + (ML20053A013)
- 05000327/LER-1981-071, Forwards LER 81-071/03L-0 + (ML20053A015)