Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML20052B177 + (ML20052B177)
- ML20052B178 + (ML20052B178)
- ML20052B179 + (ML20052B179)
- ML20052B180 + (ML20052B180)
- ML20052B184 + (ML20052B184)
- ML20052B186 + (ML20052B186)
- ML20052B188 + (ML20052B188)
- ML20052B189 + (ML20052B189)
- ML20052B190 + (ML20052B190)
- ML20052B191 + (ML20052B191)
- ML20052B193 + (ML20052B193)
- ML20052B194 + (ML20052B194)
- ML20052B197 + (ML20052B197)
- ML20052B199 + (ML20052B199)
- ML20052B200 + (ML20052B200)
- ML20052B201 + (ML20052B201)
- ML20052B203 + (ML20052B203)
- ML20052B205 + (ML20052B205)
- ML20052B206 + (ML20052B206)
- ML20052B207 + (ML20052B207)
- ML20052B209 + (ML20052B209)
- 05000331/LER-1979-021, Forwards Updated LER 79-021/01X-1 + (ML20052B210)
- ML20052B212 + (ML20052B212)
- ML20052B214 + (ML20052B214)
- ML20052B215 + (ML20052B215)
- ML20052B216 + (ML20052B216)
- ML20052B217 + (ML20052B217)
- 05000331/LER-1979-021-01, During Surveillance Testing Min Flow Valve (MOV 2009) for Rgr (LPCI) Pumps 1P-229A & 1P-229C Failed to Open.Caused by Stripped Operator Worm Gear.Worm,Gear,Quad Rings & O Rings Replaced + (ML20052B218)
- ML20052B220 + (ML20052B220)
- ML20052B221 + (ML20052B221)
- ML20052B222 + (ML20052B222)
- ML20052B224 + (ML20052B224)
- ML20052B225 + (ML20052B225)
- ML20052B226 + (ML20052B226)
- ML20052B227 + (ML20052B227)
- ML20052B228 + (ML20052B228)
- IR 05000326/1982001 + (ML20052B229)
- ML20052B230 + (ML20052B230)
- ML20052B231 + (ML20052B231)
- 05000409/LER-1982-004, Forwards LER 82-004/03L-0 & Updated LER 81-015/01X-1. Detailed Event Analysis Submitted + (ML20052B232)
- 05000285/LER-1982-006, Forwards LER 82-006/03L-0 + (ML20052B234)
- 05000285/LER-1982-006-03, /03L-0:on 820323,during Surveillance Test ST-ISI- WD-1,F.1,valve HCV-506A Failed to Close Via Control Room Switch.Caused by Solenoid Valve Malfunction.Solenoid Valve Disassembled,Cleaned & Reassembled + (ML20052B236)
- ML20052B237 + (ML20052B237)
- 05000346/LER-1982-017, Forwards LER 82-017/03L-0 + (ML20052B238)
- 05000409/LER-1982-004-03, /03L-0:on 820329,emergency Svc Water Supply Sys Suction Hoses Leaked During First Positive Pressure Hydrostatic Surveillance Test.Caused by Flat Spot in Hose Fitting Castings.Spot Filed & Hose Reclamped + (ML20052B240)
- ML20052B241 + (ML20052B241)
- 05000346/LER-1982-017-03, /03L-0:on 820323,valve CS20 Discovered Locked in Wrong Position.Caused by Personnel Error.Shift Operators Retrained on Safety Significance & Implications of Having Locked Valves in Abnormal Positions + (ML20052B242)
- ML20052B244 + (ML20052B244)
- ML20052B245 + (ML20052B245)
- ML20052B247 + (ML20052B247)
- IR 05000206/1982012 + (ML20052B248)