- 05000277/LER-1981-040, Forwards LER 81-040/01T-0.Detailed Event Analysis Encl + (ML20031F815)
- IR 05000528/2019004 + (ML20031F817)
- B10255, Application for Amend to License DPR-21.Changes Establish Common Water Level Ref Above Bottom of Reactor Vessel Per NUREG-0737 Item II.K.3.27 + (ML20031F818)
- ML20031F820 + (ML20031F820)
- 05000366/LER-1981-091-03, /03L-0:on 810917,during steady-state Operation at 1942 Mw,Torus Vacuum Relief valve,2T48-F310,was Found Open. Caused by Component Failure.New Switch Installed.Design Change Initiated to Install Compatible Design Switches + (ML20031F822)
- ML20031F823 + (ML20031F823)
- ML20031F824 + (ML20031F824)
- 05000277/LER-1981-040-01, /01T-0:on 810923,review of Rockbestos RSS-6-104 & RSS 6-110 Cables,Used in Safety Relief Valve Acoustic Monitoring Sys,Revealed Potential Failure at Elevated Temps Following LOCA or Pipe Break Accident + (ML20031F825)
- ML20031F826 + (ML20031F826)
- ML20031F827 + (ML20031F827)
- ML20031F828 + (ML20031F828)
- IR 05000293/1981017 + (ML20031F829)
- ML20031F830 + (ML20031F830)
- 05000369/LER-1981-156, Forwards LER 81-156/03L-0 + (ML20031F831)
- ML20031F833 + (ML20031F833)
- ML20031F834 + (ML20031F834)
- ML20031F835 + (ML20031F835)
- ML20031F836 + (ML20031F836)
- 05000369/LER-1981-156-03, /03L-0:on 810911,channel 3 of Reactor Protective Sys Instrumentation Monitoring Reactor Coolant Flow in Loop B Did Not Agree W/Other Loop B Flow Channels.Caused by Differential Pressure Transmitter Out of Calibr + (ML20031F838)
- ML20031F839 + (ML20031F839)
- ML20031F840 + (ML20031F840)
- 05000369/LER-1981-157, Forwards LER 81-157/03L-0 + (ML20031F841)
- ML20031F843 + (ML20031F843)
- ML20031F844 + (ML20031F844)
- 05000321/LER-1981-102, Forwards LER 81-102/03L-0.Detailed Event Analysis Encl + (ML20031F845)
- 05000369/LER-1981-157-03, /03L-0:on 810911,reactor Coolant Loop D Overtemp Delta T & Overpower Delta T Reactor Protection Sys Instrumentation Found Inoperable.Caused by General Drift in Value of Processing Components Characteristics + (ML20031F847)
- ML20031F850 + (ML20031F850)
- ML20031F851 + (ML20031F851)
- IR 05000566/1981008 + (ML20031F852)
- AECM-81-406, Forwards Addl Updated Info Re SER,NUREG-0831,per NRC Request + (ML20031F853)
- ML20031F854 + (ML20031F854)
- ML20031F855 + (ML20031F855)
- 05000321/LER-1981-102-03, /03L-0:on 810914,oil Leak Developed on Oil Sys. Caused by Torn Diaphragm on HPCI Robert Shaw Control Valve Resulting from Component Defect in Valve.Valve Replaced & New Diaphragm Installed + (ML20031F856)
- ML20031F857 + (ML20031F857)
- ML20031F858 + (ML20031F858)
- GO2-81-336, Interim Deficiency Rept Re Out of Calibr Torque Wrenches, Initially Reported 810814.Review of Special Requirements Checklist for Sampling Bolted Installations Performed.Next Rept by 811120 + (ML20031F860)
- 05000272/LER-1981-087, Forwards LER 81-087/04L-0.Detailed Event Analysis Encl + (ML20031F861)
- ML20031F863 + (ML20031F863)
- ML20031F864 + (ML20031F864)
- ML20031F865 + (ML20031F865)
- 05000272/LER-1981-087-04, /04L-0:on 810908,sea Turtles Removed from Circulating Water Sys Intake Trash Bars.Caused by Stressed Turtles Becoming Impinged on Bars.Trash Bars Will Be Observed & Cleaned When Necessary + (ML20031F869)
- IR 05000553/1981007 + (ML20031F870)
- ML20031F871 + (ML20031F871)
- ML20031F872 + (ML20031F872)
- 05000346/LER-1981-053, Forwards LER 81-053/01T-0 + (ML20031F874)
- 05000245/LER-1981-028, Forwards LER 81-028/03L-0.Detailed Event Analysis Encl + (ML20031F876)
- ML20031F878 + (ML20031F878)
- ML20031F879 + (ML20031F879)
- 05000346/LER-1981-053-01, /01T-0:on 810916,emergency Diesel Generator Tornado Missile Shield Discovered Missing from Doors 361 & 362 Following 810701 Turbocharger Changeout.Caused by Procedural Error.Shielding Replaced + (ML20031F880)
- 05000245/LER-1981-028-03, /03L-0:on 810811 During Gas Turbine Black Start Test,Generator Output Breaker Failed to Close,Preventing Output Voltage on Gas Turbine.Caused by Oxidation of Contacting Surfaces of Potentiometer.Surfaces Burnished + (ML20031F881)