- ML20028E208 + (ML20028E208)
- 05000206/LER-1982-025, Forwards LER 82-025/01X-1.Detailed Event Analysis Encl + (ML20028E209)
- IR 05000315/1982023 + (ML20028E211)
- ML20028E212 + (ML20028E212)
- ML20028E213 + (ML20028E213)
- ML20028E215 + (ML20028E215)
- ML20028E216 + (ML20028E216)
- ML20028E218 + (ML20028E218)
- 05000206/LER-1982-025-01, /01X-1:on 821012,13 & 20,three Lapses in Fire Watch Coverage Occurred.Caused by Inadequate Supervision. Two Supervisory Positions Added to Fire Watch Program.Memos Issued to Clarify Authority for Release of Fire Watches + (ML20028E219)
- ML20028E220 + (ML20028E220)
- ML20028E221 + (ML20028E221)
- ML20028E222 + (ML20028E222)
- ML20028E223 + (ML20028E223)
- ML20028E224 + (ML20028E224)
- ML20028E226 + (ML20028E226)
- ML20028E227 + (ML20028E227)
- ML20028E228 + (ML20028E228)
- ML20028E229 + (ML20028E229)
- 05000316/LER-1983-002, Forwards LER 83-002/01T-0 + (ML20028E230)
- ML20028E231 + (ML20028E231)
- PNO-III-83-005, on 830115,crack Indication Found in 28-inch Recirculation Pipe.Indication Found in Weld Area Where Pipe Joins Reactor safe-end & Is 1-inch Long in Circumferential Position & 16% of Pipe Wall Thickness + (ML20028E232)
- 05000316/LER-1983-002-01, /01T-0:on 830111,during Surveillance Test on Reactor Coolant Pump Fire Protection Water Sys,Flow Was Not Indicated to Pumps 1 & 4 When Sys Actuated.Caused by Plugged Strainer.Strainer Removed,Cleaned & Returned to Svc + (ML20028E233)
- 1CAN018304, Informs That Licensee Formally Notified NRC Resident Inspector That Util Completed Monthly Reporting Requirement on RCS Equilibrium Activity Levels for Cycle 5 Operations. Monthly Rept for Future Cycles Will Be Discontinued + (ML20028E234)
- ML20028E235 + (ML20028E235)
- 05000266/LER-1982-028, Forwards LER 82-028/03L-0 + (ML20028E236)
- ML20028E237 + (ML20028E237)
- 05000266/LER-1982-028-03, /03L-0:on 821215,routine Test on Fire Detection Sys Found Panel D407 Which Monitors Unit 1 Rod Drive Room Inoperable.Caused by Blown Fuse.Fuse & Indication Lights Replaced on 821215.Detection Sys Undergoing Design Review + (ML20028E238)
- ML20028E239 + (ML20028E239)
- 05000237/LER-1982-056, Forwards LER 82-056/03L-0 + (ML20028E240)
- ML20028E241 + (ML20028E241)
- 05000237/LER-1982-056-03, /03L-0:on 821218,rod Block Setpoint of 12.2% Found on APRM 6.Caused by Setpoint Drift.Aprm 6 Bypassed While Rod Block Setpoint Readjusted + (ML20028E242)
- TXX-3609, Interim Deficiency Rept Re Pacific Pump multi-vane Diffuser Cracking.Initially Reported on 820414.Applicant Awaiting Westinghouse Rept.Completion by 830301 Anticipated + (ML20028E243)
- ML20028E245 + (ML20028E245)
- ML20028E246 + (ML20028E246)
- 05000316/LER-1982-110-03, /03L-0:on 821220,during Refueling Shutdown, Operator Discovered Fire Door 358 Would Not Close Completely.Caused by Damage to Bottom of Door,Apparently by Striking Some Object.Door Repaired + (ML20028E247)
- 05000316/LER-1982-111-03, /03L-0:on 821221,during Cold Shutdown,Inactive Leaf of Fire Door 388 Would Not Latch Properly.Caused by One Missing & One Damaged Latch Plate.Cause of Damage Unknown.New Latch Plates Installed + (ML20028E248)
- ML20028E249 + (ML20028E249)
- ML20028E250 + (ML20028E250)
- 05000316/LER-1982-112-03, /03L-0:on 821220,during Refueling Shutdown,Fire Door 374 Unable to Close Properly When Both Leaves of Double Door Opened.Caused by Damaged Sequencer,Due to Unknown Origin.Sequencer Replaced + (ML20028E251)
- ML20028E252 + (ML20028E252)
- PNO-III-83-006, on 830115,security Officer Tripped on Stairs, Jarring Pistol Loose Which Accidentally Discharged.No Injuries Reported.Investigation Underway + (ML20028E254)
- ML20028E255 + (ML20028E255)
- 05000295/LER-1982-048, Forwards LER 82-048/03L-0 + (ML20028E256)
- ML20028E258 + (ML20028E258)
- ML20028E259 + (ML20028E259)
- 05000295/LER-1982-048-03, /03L-0:on 821213,blower Belt for Miscellaneous Vent Stack Monitor ORT-PR18 A&B Found Broken.Caused by Normal End of Life.Belt & Defective Relay in Instrument Fail Alarm Circuitry Replaced + (ML20028E260)
- ML20028E261 + (ML20028E261)
- ML20028E262 + (ML20028E262)
- 05000249/LER-1982-049, Forwards LER 82-049/03L-0 + (ML20028E264)
- ML20028E265 + (ML20028E265)
- ML20028E266 + (ML20028E266)