List of results
- ML20027B754 + (ML20027B754)
- ML20027B755 + (ML20027B755)
- 05000259/LER-1982-064-03, /03L-0:on 820823,determined Station II Cable Tray Fixed Spray Sys Did Not Meet Tech Specs.Caused by Apparent Restriction in Supply Line Strainer.Strainer Cleaned & Flushed + (ML20027B756)
- ML20027B757 + (ML20027B757)
- ML20027B759 + (ML20027B759)
- ML20027B761 + (ML20027B761)
- IR 05000546/1982016 + (ML20027B763)
- ML20027B764 + (ML20027B764)
- IR 05000334/1982014 + (ML20027B766)
- 1CAN098208, Forwards Intake Impingement Monitoring Data for Aug 1982 + (ML20027B767)
- ML20027B768 + (ML20027B768)
- ML20027B769 + (ML20027B769)
- ML20027B770 + (ML20027B770)
- ML20027B772 + (ML20027B772)
- IR 05000263/1982010 + (ML20027B773)
- ML20027B774 + (ML20027B774)
- 05000259/LER-1982-063, Forwards LER 82-063/03L-0 + (ML20027B775)
- ML20027B776 + (ML20027B776)
- 05000328/LER-1982-109, Forwards LER 82-109/03L-0 + (ML20027B777)
- ML20027B778 + (ML20027B778)
- ML20027B780 + (ML20027B780)
- 05000259/LER-1982-063-03, /03L-0:on 820827,reactor Bldg/Turbine Air Lock Doors Opened at Same Time.Caused by Lock Being Out of Adjustment & Not Latching.Differential Air Pressure Caused Door 238 to Open When Door 237 Opened.Lock Repaired + (ML20027B784)
- 05000328/LER-1982-109-03, /03L-0:on 820826,during Mode 1,hot Leg Sample Valve 2-FCV-43-22 Would Not Open.Caused by Open Limit Switch Being Out of Adjustment.Switch Adjusted,Valve Tested & Returned to Svc + (ML20027B785)
- 05000339/LER-1982-053, Forwards LER 82-053/03L-0 + (ML20027B786)
- ML20027B787 + (ML20027B787)
- 05000259/LER-1982-060, Forwards LER 82-060/03L-0 + (ML20027B788)
- ML20027B789 + (ML20027B789)
- 05000339/LER-1982-053-03, /03L-0:on 820822 & 27,C Reserve Station Svc Bus de-energized to Remove Oil Sprayed on Tubular Bus,Feeder Cables & Insulators During Phase B Main Transformer Fault. Caused by Manual Shutoff to Prevent Fire + (ML20027B790)
- 05000259/LER-1982-060-03, /03L-0:on 820825,reactor & Turbine Bldg Vent Monitor Inlet Sample Line Found Disconnected.Caused by Faulty Chicago Fitting.Inlet Sample Line Reconnected to Monitor.New Hose,Fitting & Safety Clips Installed + (ML20027B791)
- PNO-I-82-062, on 820922,radiation Survey Identified Soil Contamination at Two Locations Near Radwaste Sys Waste Surge Tank.Tank Drained & Leak Source Investigated.Contaminated Soil Packaged in Metal Shipping Containers for Disposal + (ML20027B793)
- ML20027B794 + (ML20027B794)
- FVY-82-107, Application to Amend License DPR-28,revising Tech Specs Re Titles Appearing on Offsite Support Organizational Chart + (ML20027B795)
- ML20027B796 + (ML20027B796)
- 05000259/LER-1982-061, Forwards LER 82-061/03L-0 + (ML20027B797)
- ML20027B798 + (ML20027B798)
- 05000366/LER-1982-097, Forwards LER 82-097/03L-0 + (ML20027B799)
- ML20027B800 + (ML20027B800)
- ML20027B801 + (ML20027B801)
- ML20027B802 + (ML20027B802)
- 05000366/LER-1982-097-03, /03L-0:on 820819,drywell hydrogen-oxygen Analyzer Instrument Channels a & B Functioned Erratically & Declared Inoperable.Caused by Air Inleakage by Packing of Drywell/ Torus Sample Valves.Packing Tightened + (ML20027B803)
- ML20027B804 + (ML20027B804)
- 05000259/LER-1982-061-03, /03L-0:on 820826,continuous Air Monitor 1-RM-90-250 Declared Inoperable.Caused by Broken Drive Belt Due to Normal Wear.Drive Belt Replaced + (ML20027B805)
- 05000366/LER-1982-081, Forwards LER 82-081/03L-0 + (ML20027B806)
- ML20027B807 + (ML20027B807)
- 05000416/LER-1982-061, Forwards LER 82-061/03L-0 + (ML20027B808)
- ML20027B809 + (ML20027B809)
- 05000366/LER-1982-081-03, /03L-0:on 820825,torus High Water Level Alarm Activated Following Reactor Scram.Caused by Reactor Scram & Group I Isolation Due to MSIV Failing & Closing.Reactor Pressure Controlled by Opening Steam Relief Valves + (ML20027B810)
- 05000259/LER-1982-074, Forwards LER 82-074/03L-0 + (ML20027B811)
- ML20027B812 + (ML20027B812)
- 05000416/LER-1982-061-03, /03L-0:on 820830,smoke Detector Zone Covering Standby Svc Water Pumphouse Alarmed & Would Not Clear.Caused by Dust Contamination of Ionization Smoke Detectors. Detectors Cleaned + (ML20027B813)