ML20027B800

From kanterella
Jump to navigation Jump to search
Forwards LER 82-097/03L-0
Date released: 02/10/2020 Download: ML20027B800


LER 82-097/03L-0:on 820819,drywell hydrogen-oxygen Analyzer Instrument Channels a & B Functioned Erratically & Declared Inoperable.Caused by Air Inleakage by Packing of Drywell/ Torus Sample Valves.Packing Tightened
ML20027B803
Person / Time
Site: Hatch 
Issue date: 09/16/1982
From: Tipps S
GEORGIA POWER CO.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
Download: ML20027B803 (2)
Forwards LER 82-097/03L-0
ML20027B799
Person / Time
Site: Hatch 
Issue date: 09/16/1982
From: Nix H
GEORGIA POWER CO.
To: OREILLY J P
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
Download: ML20027B799 (1)