- 05000346/LER-1981-047-03, /03L-0:on 810816,steady State Quadrant Power Tilt Limit Was Exceeded Due to Large Difference in RCS Cold Leg Temp.Caused by Mismatch in Feedwater Flows to once-through Steam Generators.Plant Startup Procedure Modified + (ML20010G665)
- 05000309/LER-1981-019-03, /03L-0:on 810904,channel D,Temp Monitor/Lp Calculator Setpoint Indicated Below Tech Spec Limit.Caused by Faulty Amplifier Module within Margin Calculator.Module Replaced & Setpoints Verified + (ML20010G666)
- IR 05000298/1981013 + (ML20010G667)
- ML20010G668 + (ML20010G668)
- ML20010G669 + (ML20010G669)
- ML20010G670 + (ML20010G670)
- ML20010G671 + (ML20010G671)
- ML20010G673 + (ML20010G673)
- ML20010G674 + (ML20010G674)
- ML20010G675 + (ML20010G675)
- ML20010G676 + (ML20010G676)
- ML20010G677 + (ML20010G677)
- ML20010G680 + (ML20010G680)
- ML20010G681 + (ML20010G681)
- ML20010G682 + (ML20010G682)
- ML20010G683 + (ML20010G683)
- ML20010G685 + (ML20010G685)
- 05000220/LER-1981-042, Forwards LER 81-042/04T-0 + (ML20010G688)
- ML20010G689 + (ML20010G689)
- A810025, Commits to Four Listed Criteria Re Future Disc Insps for Westinghouse Low Pressure Turbines.Util Working W/ Westinghouse in Replacing Low Pressure Turbine Rotors + (ML20010G690)
- ML20010G691 + (ML20010G691)
- ML20010G692 + (ML20010G692)
- 05000220/LER-1981-042-04, /04T-0:on 810831,during Weekly Environ Radiation Monitor Insp,Only Six Monitors Found Functioning Due to Defective Power Supply Units.Cause Unknown.Portable Monitor Installed + (ML20010G693)
- ML20010G695 + (ML20010G695)
- ML20010G696 + (ML20010G696)
- 05000318/LER-1981-039, Forwards LER 81-039/03L-0 + (ML20010G698)
- ML20010G699 + (ML20010G699)
- ML20010G700 + (ML20010G700)
- AECM-81-349, Interim Rept 1 Re Corrosion to Standby Svc Water Sys Pump, Initially Reported on 810225.Acid Addition Sys Operable, Which Will Provide Controlled Method of Adding Acid & Proper Mixing of Acid & Water.Final Rept Due on 811101 + (ML20010G701)
- 05000318/LER-1981-039-03, /03L-0:on 810810,reactor Protection Sys Channel D Trip Points for Hi Power,Thermal Margin/Low Pressure & Axial Shape Index Bypassed to Troubleshoot Erratic Tc Indications.Possibly Caused by Detector or Loose Connection + (ML20010G702)
- ML20010G704 + (ML20010G704)
- 05000318/LER-1981-041, Forwards LER 81-041/03L-0 + (ML20010G705)
- ML20010G706 + (ML20010G706)
- ML20010G708 + (ML20010G708)
- ML20010G709 + (ML20010G709)
- 05000339/LER-1981-065, Forwards LER 81-065/03L-0 + (ML20010G710)
- ML20010G711 + (ML20010G711)
- 05000339/LER-1981-065-03, /03L-0:on 810814,power Range Channel N-41 Bistable Setpoints for Low & High Range Overpower Reactor Trips & for Permissives P-8 & P-10 Overpower Trips Were Found High. Probably Caused by Incorrect Calibr.Channel Recalibr + (ML20010G714)
- ML20010G716 + (ML20010G716)
- ML20010G717 + (ML20010G717)
- 05000311/LER-1981-089-03, /03L-0:on 810817,discovered Linkage Between Trip Mechanism & Trip Valve Loose During Wear & Alignment Check on Auxiliary Feedwater Pump 23.Caused by Bolts Which Became Loose Through Normal Vibration.Bolts Tightened + (ML20010G718)
- 05000369/LER-1981-139, Forwards LER 81-139/03L-0.Detailed Event Analysis Encl + (ML20010G719)
- ML20010G720 + (ML20010G720)
- ML20010G721 + (ML20010G721)
- ML20010G723 + (ML20010G723)
- ML20010G725 + (ML20010G725)
- ML20010G726 + (ML20010G726)
- 05000369/LER-1981-139-03, /03L-0:on 810812,loss of Water from Reactor Coolant Inventory Exceeded Tech Spec Limit for 4-h Period W/O Operations Knowledge.Caused by Failure to Isolate Reciprocating Charging Pump 1 Relief Valve Prior to Maint + (ML20010G727)
- ML20010G730 + (ML20010G730)
- ML20010G732 + (ML20010G732)
- 05000366/LER-1981-078, Forwards LER 81-078/03L-0 + (ML20010G734)